Download presentation
Presentation is loading. Please wait.
Published byAndrew Patrick Modified over 9 years ago
1
FP420 Low and high voltage supply Henning.E.Larsen@gmail.com INFN/Univ. of Torino larsen@cern.ch Sep. 2007
2
HV-LV supply segmentation Damage depends on distance from the beam. Required bias voltage and current increase with radiation dose. Drawing: From Ray Thompson PT1000 Temperature sensor? Pixels:50x400um and 400x50um MCC: Module Controller Chip 1 Superlayer = 2 Hybrids/Blades 4 detectors 2D 1 MCC 1 Read-out interface
3
HV+LV and temperature channel count HV: 0 to -100V LV: 1.6V,2.0V One SuperlayerOne pocketOne stationFp420 experiment 4 det.+ FE+1MCC with 5 Superlayerswith 3 pocketswith 4 stations Low voltage 21030120 High voltage 21030120 Si detector Temperature monitor channels One SuperlayerOne pocketOne stationFp420 experiment With one probewith 5 Superlayerswith 3 pocketswith 4 stations Temperature 151560 Gastof and Quartic channel count and level????
4
Commercial: Caen Wiener is similar Cryostat 2 LHC tunnel EASY 3000 A3486 2x48V Power A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 A3501 A3801 EASY 3000 A3501 12ch HV A3540 A3006 FP420 pocket FP420 pocket FP420 pocket 10m Quartic Gastof CMS and Atlas counting room SY1527 A1676A Crate Ctl A1676A Crate Ctl Atlas / CMS Slow control 500m Cryostat 1 LHC tunnel EASY 3000 A3486 2x48V Power A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 12ch LV A3009 A3501 A3801 EASY 3000 A3501 12ch HV A3540 A3006 FP420 pocket FP420 pocket FP420 pocket 10m Quartic Gastof
5
CAEN: EASY3000 crate, 3 pockets Silicon detector+Quartic+Gastof A3009: LVA3501: HV A3801: TempMon A3540, HV A3006, LV Spare: 14 Slots A3486: 2 x 48V Gastof/Quartic crate Silicon tracker
6
Wiener solution Also proposed an all-in-tunnel solution which however needs hardware modifications and radiation tests Radiation tests required
7
CAEN, EASY3000 modules, Radiation status
8
Rad test facilities SEU (Single event upset): (Proton) –TSL proton beam at Uppsala in Sweden which has a diameter of 15 to 20cm NIEL (Non Ionising Energy Loss) : (neutron) –PROSPERO nuclear reactor at Valduc near Dijon in France which produces neutrons at 1Mev energy TID (Total Ionising dose): (Gamma) –cobalt 60 source in Cassacia in Italy near rome ….
9
CAEN: Can bus test over 520m need to add those bias resistors, to improve noise margin
10
CAN bus collision error Example of collision. B end is transmitting, then A suddenly starts transmitting as well (upper trace) => collision and broken communciation. =A transmitted data =A received data =B end cable signal B sends A sends
11
Conclusions on communication cable test With CAEN’s implementation, of 250kbaud, timing violations are detected : Need either 125kbaud or modify timing of can bus = modification can only be done by CAEN (20k€) Cable bandwidth SCEM 04.21.52.xxx.x allows 1Mbaud Clock transmission has been tested to work with a duty cycle distortion of <10% at 1MHz This family of cables would support the CAN bus communication at 125kBaud over 500m using the standard CAN aribtration and protocol. EASY3000 crate may catch fire!
12
Status Sep. 2007 CAEN solution is at the most advanced state: Will fit into the tunnel in 3(4) crates includes: –Temperature monitor –Quartic/Gastof supplies (=1 crate) –Very few long cables: Power 400V+communication+48V –May need 400V noise filter A3000NF (ask Detlef for <200W). This module has not been rad. tested but its an entirely passive components. Could be outside of tunnel! Wiener supply solution: –LV in tunnel. HV in Counting room. But also a all-in-tunnel version –Temperature in counting room HV 100V(ok?) module A3501 has not been radition tested. Equivalent to A3540 (12x4KV) which is approved for Atlas
13
Conclusion on power supplies Both CAEN and Wiener are still candidates Wiener and CAEN need radiation tests CAEN need customization on communication Wiener need customization on HV in their all-in-tunnel solution
14
Actions Specify radiation requirements and test protocol for Wiener (and for CAEN) Find locations for above radiation qualification tests for Wiener and for CAEN Radiation test CAEN HV 3501(Si bias) and A3006 (4-16V Gastof /Quartic)
Similar presentations