Access Control ( Hardware ) June 25, 2010 Created by Castaly / Andy Chen
2
Access Control Guideline Introduction GV-Reader Series GV-Controller Series Accessories Advance Section Summary FAQ
3
Guideline for Access Control
4
AS-H Access Control Introduction
5
What is access control? –Access Control is any mechanism by which a system grants or revokes the right to access some data, or perform some action. Normally, a user must first login to a system, using some Authentication system. Next, the Access Control mechanism controls what operations the user may or may not make by comparing the UserID to an Access Control database. Introduction
6
In order to install an Access Control System, you will need the hardware items below. –GV-Controller –GV-Readers / GV-GF Fingerprint Reader Introduction
7
AS-H01 Access Control System Structure
8
System Structure for Access Control
9
AS-H02 GV-Reader Series
10
What’s Reader? Data Reader A input device A combination of readers or tags
11
GV-Reader Series Products –GV-Reader 1251 –GV-Reader 1352 V2 –GV-GF1900 –GV-GF1901 –GV-GF1902 –GV-AS100 What’s Reader?
12
GV-Reader 1251 –Support Wiegand 26 / RS485 Interface –Frequency: 125KHz –Type of Card: E –Card / Tag distance: 4 cm / 3 cm –Temperature: -20 ~ 65 C What’s Reader?
13
GV-Reader 1352V2 –Support Wiegand 26 / RS485 Interface –Frequency: 13.56MHz –Type of Card: M / F –Card / Tag distance: 5 cm / 4 cm –Temperature: -20 ~ 65 C What’s Reader?
14
GV-Reader 1251 GV-Reader 1352V2 Communication Wiegand 26 / RS-485 Wiegand 26 / RS-485 Frequency125 KHz13.56 MHz Card / Tag TypeEM / F Distance between Card & Reader 4 / 3 (cm)5 / 4 (cm) Temperature -20 ~ 65°C / -4 ~ 149°F -20 ~ 65°C / -4 ~ 149°F What’s Reader?
15
GV-GF Enrolled Installation What’s Reader?
16
GV-GF1900 –Wigand 26 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 12 mm x 16 mm –Sensor: Capacitive –No output –Operate Mode: Card + Finger What’s Reader?
17
GV-GF1901 –Wigand 26 / RS485 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 13.2 mm x 18.5 mm –Sensor: Capacitive –Support 1 output ( 240V, 2.5A ) –1900 Fingerprints –Operate Mode: Card + Finger or Finger Only mode What’s Reader?
18
GV-GF1902 –Wigand 26 / RS485 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 17 mm x 20 mm –Sensor: Optical –Support 1 output ( 240V, 2.5A ) –1900 Fingerprints –Operate Mode: Card + Finger or Finger Only mode What’s Reader?
19
GV-GF1900GV-GF1901GV-GF1902 產品差異產品差異 CommunicationWiegand 26 RS-485 Wiegand 26 RS-485 Frequency13.56 MHz Card / Tag TypeFFF Temperature 0 ~ 65°C / 32 ~ 149°F Finger 感應介面電容式 光學式 Finger 感應面積 12x16(mm) 17x20(mm) I / O 介面 None1 Port (240V/2.5A) Support ModeCard + Finger Mode Finger only Mode Card + Finger Mode Finger only Mode Card + Finger Mode 優點 1. 感應速度快 2. 不受光線干擾 1. 感應速度快 2. 不受光線干擾 1. 指紋偵測面積較大 2. 無手汗症 & 乾手症感 應不良的狀況 缺點 1. 對於手汗症 & 乾手 症感應較差 2. 無 RS-485 介面 3. 無 output 輸出 1. 對於手汗症 & 乾手症感 應較差 1. 光線干擾問題 2. 感應速度較慢
20
AS-H03 Access Control GV-Controller Series
21
Access Control GV-AS200 Controller GV-AS400 Controller GV-AS100 Controller GV-ASBox
22
GV-AS200 Controller GV-AS200
23
GV-AS200 Controller –Two to four doors controller –Support 4 Wiegand card reader 26~40 bits –Support up to 8 card readers via RS485 –4 Inputs / 3 outputs for each door Inputs: Sensor, Button, Fire, Tamper Outputs: Alarm, Door, Urgent GV-AS200
24
GV-AS200 Controller –What if there is a disconnection between GV- AS200 controller and GV- ASManager, can GV-AS200 controller still be operated? 65536 event buffer 10000 access card information –What happens to GV-AS200 controller if connection is back? GV-AS200
25
GV-AS200 Controller –Not support GV-GFV1901, GV- GFV1902 RS485 interface –GV-GF can ONLY use Wiegand interface –Connect to ASManager via RS485 or TCP/IP RS485 must connect to GV-Hub, GV-Com or GV-Net I/O card v3.1 –Connect Card Reader to AS200 Controller via Wiegand or RS485 GV-AS200
26
GV-AS400 Controller GV-AS400
27
GV-AS400 Controller –A four doors controller –Support 8 Wiegand card reader 26~64 bits –Support up to 8 GV-Readers / GV-GF via RS485 –16 Inputs / 16 outputs Max voltage / current difference between 1~8 outputs and 9~16 outputs GV-AS400
28
GV-AS400 Controller –Connect up to 4 GV-I/O box GV-IOBox 4,8,16 Max 80 inputs / 80 outputs –GV-Reader / GV-GF can connect up to 8 via RS485 connection Only compatible with GeoFinger1901/1902 –Not support Security mode GV-AS400
29
GV-AS400 Controller –What does it mean when ” low battery” error message shows up in GV-ASKeypad? AS400 remains 10 hours after the battery stops working. GV-AS400
30
GV-AS100
31
–One door controller –Support 1 Wiegand interface ( 26~64 bits ) –65536 event buffer –Support 1000 Card information –3 inputs and 2 outputs –No support tag GV-AS100
32
–Program Mode *227 Access the card manager function *276 Access Security Mode *347 Display system information *738 Access Parameter Setting *737 Restores GV-AS100 to factory default GV-AS100
33
–Program Mode *837 Test numeral keys to see if they can be displayed properly * Used to cancel the selection or go back to previous page 0 Used to go to the next page # Used to save the data that was modified or programmed in the system and quit. GV-AS100
34
GV-AS100 With GV-ASBox –Support Doors 1 door to 2 doors –The card information 1000 to 40000 –The internet connection RS485 to TCP/IP –I/O 3 IN / 2 Out to 11 IN / 10 Out GV-AS100 GV-ASBox
35
GV-AS100 With GV-ASBox –Wigand interface 2 in total –RS485 interface 1 in total –GV-GF 4 in total ( ASBox ) GV-AS100 GV-ASBox
36
GV-AS100 With GV-ASBox –Web Setting Switch When this switch is on, you can modify advance setting of GV-AS100 through the web interface. When the switch is off, advance setting are not accessible. –Briefly went through web interface of GV-AS100 with GVAS- box. ( Very similar to AS400 ) GV-AS100 GV-ASBox
37
AS-H04 Access Control Accessories
38
Accessories GV-Keypad GV-Battery
39
GV-Keypad –Load default in AS200 and ASBox –Upgrade Firmware –Setting Parameter, such as ID, local time –Display System information, such as memory status, IP address, firmware version…etc
40
GV-Battery –Act as UPS –4 hours max Life span –Can be used in GV-AS200 Controller and other GeoVision device. –Recommended third party battery Yuasa NPH 5-12 GP1245 ( CSB )
41
GV-Battery –Minimum Requirement for the third-party battery Voltage 12v with suggested 5A Must have Terminal for Power cable connection The size of Battery approximately around the below –Length 3.54” –Width 2.75” –Height 3.93” GV-Battery
42
AS-H05 Access Control Advance Section – Demo
43
1)How to connect GV-Reader via RS-485? 2)How to connect GV-Reader via Wiegand? 3)How to setup I/O in GV-AS 200 controller? 4)How to setup I/O in GV-AS400 controller? 5)How to setup I/O in GV-AS100 with ASBox controller? 6)How to add / delete a card in GV- AS100? 6)How to enable / disable a card in GV-AS100? 7)How to restore Factory Default in GV-AS100? Advance Section - Demo
44
Access Control Summary AS-H06
45
Review All different Hardware’s features Summary
46
Review All different Hardware’s features Summary
47
Access Control FAQ