EC front unit status
2
Outline Conclusions from mechanical prototype and actions taken Status of electrical prototype KIT’s work for TA Dev plan (tests) 2
3
Reminder: EC-front elements 3 different PCBs: First one (EC DYNODE board) allows to reroute half of the dynodes of 1 MAPMT so that they are aligned perpendicularly to the others. It covers the 4 MAPMTs. Second one (EC ANODE board) covers one MAPMT but has dimensions reduced allowing a flex pcb to get out. It is used to collect signal from the anodes and send them to the ASICs. Third one (EC HV board) covers one MAPMT. It welcomes the dynodes and supplies the HV to the EC-dynode board which transmits it to the 4 MAPMTs. Per EC unit: 1 EC-DYNODE board 4 EC-ANODE boards 1 EC-HV boards UV filter MAPMT Flexible pcb toward EC-back HV cables toward HV box 3
4
Front view 6 mm outer diameter 3.1 mm inner diameter Radius of the corner : R2.2 55 mm Thickness: 1 mm 11 mm 6 mm 17 mm Outer and inner diameters 10 and 6 mm 19.62 mm 53 mm 51 mm Thickness: 3 mm 9.3 mm 17 mm ~2 mm Dimensions of PDM frame 4
5
EC unit inside PDM frame EC_dynode is 54.5 mm x 54.5mm therefore it will lay on the PDM structure where the distance goes from 55 mm to 53 mm 2 adjacent EC_anodes soldered to the MAPMT pins (going through holes of the EC_dynode) should fit in 53 x 53 mm The EC_HV soldered to extensions coming from the EC_dynode should fit also in the 53 x 53 mm MAPMT Ec_dynode Ec_anode Ec_HV 5
6
EC unit assembly test at APC It looked ok… 6
7
MATRA mechanical prototype The mechanical prototype was finished 12/07 MATRA people checked if the proto was fitting inside a homemade version of the mechanical structure of 1 EC unit They observed that the EC_anodes and EC_HV were overlapping with the structure meaning that they were going over the 53 x 53 mm… Calculations based on the CAD files showed that indeed the dimensions of EC_anode and EC_HV are lightly too much… see following slides. Mechanical prototype 7
8
8.32 mm EC_dynode dimensions 8
9
1.16 mm EC_anode dimensions 6 mm (8.32 – 2 x 1.16) 23.7 mm24 mm 53.7 mm The distance (6 mm) between two EC_anodes is needed to let the flexible cables go through this gap. It was the leading idea of the EC front unit design. But then the global dimensions are 53.7 x 53.7 mm… we missed that . 9
10
1.16 mm How to fix the problem for the EC_anodes The larger holes on the edge are 2 mm large ones and there is no routing around. Therefore EC_anode rigid pcb could be reduced significantly by removing the parts MATRA did that on the mechanical prototype to perform the potting test. 10
11
6 mm 21.7 mm21.1 mm 48.8 mm New version of the EC_anodes and EC_HV Action: EC_anodes were corrected end of July 2012. EC_HV in September 2012. Action: EC_anodes were corrected end of July 2012. EC_HV in September 2012. In this version, the extension pins coming from the EC_dynode toward the EC_HV will go next to the EC_anodes not anymore through. 11
12
6 mm 21.7 mm21.1 mm 48.8 mm New version of the EC_anodes and EC_HV Action: EC_anodes were corrected end of October/beginning of November Action: EC_anodes were corrected end of October/beginning of November 12 Before Now
13
Mechanical prototype potting Top view (fake filters) Bottom view (cables and screw) Lateral view 1 Lateral view 2Lateral view 3Lateral view 4 13
14
Mechanical prototype potting Clearly the result is not good. MATRA thinks that the problem comes from the fact that the EC_dynode lays on the mold’s shoulder (from 55 mm to 53 mm), this way the air can not easily escape and this creates bubbles that explode. MAPMT Ec_dynode EC_anodes EC_HV Filters Mold 3D view from MATRA Picture of the mold (2 parts) Actions Actions: - Modification of the mold (sept 2012) - Potting will be done in vacuum Actions Actions: - Modification of the mold (sept 2012) - Potting will be done in vacuum 14
15
Integration of the mechanical prototype potted 15 After all (reduction of the size of the fake pcbs and removal of the central column), it fits in the mechanical frame
16
Electrical prototype Due to manpower issue, MATRA started the electrical prototype of the EC beginning of this week It should be ready next week It is be composed of: 4 real MAPMTs equipped with UV filters selected by Philippe 1 EC_dynode real PCB 2 EC_anodes of each type real PCB (old version) 1 EC_HV (old version) All pcbs have been provided by KIT from the spares of boards produced for TA. KIT is in charge of the assembly of the EC front units for TA and has started assembly tests 16
17
TA EC front unit 17 Slides from Andreas E.
18
TA EC front unit 18 Slides from Andreas E.
19
Development plan (tests) 19 Once the EC front unit electrical prototype will be produced Connection to the HVPS and HV ON to check current and MAPMTs power and analog signals, without light (in black box) Connection to the HVPS and HV ON to check current and MAPMTs power and analog signals, with light ON (in black box) When we will have a working EC_ASIC – test_EC_ASIC couple 1.EC_ASIC tests with EC front unit without potting (2 weeks) HV off (Pedestal measurements, DAC linearity, PC measurements) HV on (same measurements as above) in black boxe, light off HV on (same measurements as above) in black boxe, light on 2.EC_ASIC tests with EC front unit with potting (as much time as needed) HV off (same measurements as above) HV on (same measurements as above) in black boxe, light off HV on (same measurements as above) in black boxe, light on 3.EC_ASIC tests with EC unit at 3 mbar + temperature tests To be specified