Download presentation
Presentation is loading. Please wait.
Published byTabitha Davidson Modified over 9 years ago
1
1 2 3 4 5 6 7 8 BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM FAIL DRM MODULE ENABLED 1 2 3 4 RUN MODE 1 RUN MODE 2 ADDRESS 1 5INVERT RELAY OPERATION RELAYS NOT INVERTED 5INVERT RELAY OPERATION RELAYS INVERTED 8DRM MODULE ENABLED 8 DRM MODULE DISABLED DRM MODULE ENABLED 6 7 ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM FAIL 1 2 RUN MODE 1 RUN MODE 2 1 2 RUN MODE 1 RUN MODE 2 1 2 RUN MODE 1 RUN MODE 2
2
1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 1 FLOOR 1 TO 16 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 2 FLOOR 17 TO 32 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 3 FLOOR 33 TO 48 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 4 FLOOR 49 TO 64 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 5 FLOOR 1 TO 16 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 6 FLOOR 17 TO 32 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 7 FLOOR 33 TO 48 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 FLOOR 49 TO 64
3
1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 9 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 10 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 11 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 12 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 13 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 14 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 15 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16
4
AC AC B+ B- ST TP TP 1K5 OHM LED 16VAC 40VA MAX TRANSFORMER 50/60Hz 40VA MAX MAINS INPUT +12V AUX AC AC B+ B- ST TP TP
5
4Ah (MIN) GEL CELL BACKUP BATTERY N+ N- NA NB TP TP F+ F- FIRE CONTROL SYSTEM 12 - 32VDC 6 - 21mA TO NEXT ELEVATOR CONTROLLER AC AC B+ B- ST TP TP
6
N+ N- NA NB CONTROLLER EOL ON 0V B- A+ 12V
7
S+ S- SA SB TO FIRST SLAVE FLOOR CONTROL MODULE. PRT-PX16 IN FLOOR CONTROL MODE. TAMPER SWITCH N+ N- NA NB TP TP N+ N- NA NB NETWORK COMMUNICATIONS INPUT FROM SYSTEM CONTROLLER OR PREVIOUS PROTÉGÉ SYSTEM MODULE
8
NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM
9
NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM + IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD RELAY CONTACTS ON THE MAIN ELEVATOR CONTROL BOARD SEE TEXT BUTTON VOLTAGE COMMON IN ELEVATOR CONTROL SYSTEM
10
NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM + IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD RELAY CONTACTS ON THE MAIN ELEVATOR CONTROL BOARD SEE TEXT BUTTON VOLTAGE COMMON IN ELEVATOR CONTROL SYSTEM
11
+ IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD AC AC B+ B- + - ST POWER CONNECTOR ON MAIN ELEVATOR CONTROL BOARD
12
EOL EOL ONEOL OFF 350mA 700mA 350mA 700mA FIRE OVERRIDE FIRE OVERRIDE EOL
13
1 2 3 4 5 6 7 8 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION 1 2 3 4 5 6 7 8 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION 1 2 3 4 5 6 7 8 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION 1 2 3 4 5 6 7 8 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION
14
N+ N- NA NB PC OR HOST CONTROL SYSTEM CONNECTED TO A ACC-485 SERIAL INTERFACE EOL OFF EOL ON +12 0V A+ B-
15
AC AC B+ B- + - ST 7.5Ah GEL CELL BACKUP BATTERY N+ N- NA NB TP TP F+ F- FIRE CONTROL SYSTEM 12 - 32VDC 6 - 21mA TO NEXT IRC RELAY CONTROLLER
16
N+ N- NA NB FROM PREVIOUS CONTROLLER TO NEXT IRC CONTROLLER TP TP F+ F- TAMPER SWITCH
17
AC AC B+ B- ST TP TP COLD WATER PIPE GROUNDING EARTH PEG GROUNDING ROD TO OTHER EARTH CONNECTIONS ALREADY ATTACHED TO THE EARTH PEG OR WATER PIPE MIN AWG#14 SINGLE SOLID CONDUCTOR COPPER WIRE
18
N+ N- NA NB MODULE OR CONTROLLER SUPPLYING POWER TO NETWORKED DEVICES AUX+ AUX- N+ N- NA NB NEXT MODULES ON NETWORK
19
N+ N- NA NB READER EXPANDER SUPPLYING NETWORK POWER AUX+ AUX- S+ S- SA SB NEXT FLOOR CONTROL MODULE SLAVE DEVICES CONNECTED TO THE READER EXPANDER SLAVE COMMUNICATION INTERFACE USE THE N+, N-, NA AND NB TERMIANLS.
20
+ - D0 D1 L1 L2 BZ PRX-SAM READER CONNECTION RED BLACK GREEN WHITE ORANGE BROWN BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR NEGATIVE CONNECTION. +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER PRX-NANO NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION -+-+ POWER SUPPLY 12VDC
21
+ - D0 D1 L1 L2 BZ R2 R2 R2 R2 R2 R2 R2 + - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD DATA 1 ENTRY UNIT EXIT READER READER #1 INPUT CONNECTION READER #2 INPUT CONNECTION
22
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER + - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER
23
NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + BUZZER INPUT ALARM OUTPUT POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS
24
NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + DB9 RS232 POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS PIN 2 RXD PIN 3 TXD PIN 5 GND
25
NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + RS485 POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS NA NB COM
26
NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + BUZZER INPUT ALARM OUTPUT POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS
27
NC CONNECTION SHOWN FOR LOCK RELAY 1 +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + POWER SUPPLY FOR LOCKING DEVICES MAX 30VDC
28
1K N.C. ZONE CONTACT N.C. TAMPER CONTACT N.C. ZONE INPUT COMMON AUX AUX Z1 COM Z2 Z3 COM Z4 + - DOOR1 REX1 SEN1 REN1 RESISTORS SHOULD BE LOCATED AT THE DEVICE ATTACHED TO THE ZONE ZONE INPUT SHOWN FOR ZONE 1
29
N.C. ZONE CONTACT N.C. ZONE INPUT COMMON AUX AUX Z1 COM Z2 Z3 COM Z4 + - DOOR1 REX1 SEN1 REN1 ZONE INPUT SHOWN FOR ZONE 1
30
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PGM RDxxx:03 1K5 OHM LED +12V AUX 1 2 3 4 5 6 7 8 ADDRESS 4 ADDRESS 8 ADDRESS 1 ADDRESS 2 ADDRESS 64 ADDRESS 16 ADDRESS 32 DEFAULT / RUN 1 2 3 4 ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 READER EXPANDER ADDRESS 079 5 6 7 ADDRESS 64 ADDRESS 16 ADDRESS 32
31
CROSSOVER DIRECT ETHERNET CONNECTION 8 PORT ETHERNET HUB READER EXPANDER RJ45 ETHERNET CONNECTOR MULTIPLE ETHERNET CONNECTIONS USING A ETHERNET HUB ETHERNET
32
N+ N- NA NB SYSTEM CONTROLLER SUPPLYING NETWORK POWER AUX+ AUX- N+ N- NA NB NEXT MODULE ON NETWORK STANDARD ZONE EXPANDERS CONNECTED TO THE SYSTEM CONTROLLER COMMUNICATION INTERFACE USE THE N+, N-, NA AND NB TERMIANLS.
33
N+ N- NA NB MODULE NETWORK COMMUNICATIONS
34
CROSSOVER DIRECT ETHERNET CONNECTION 8 PORT ETHERNET HUB SYSTEM CONTROLLER RJ45 ETHERNET CONNECTOR MULTIPLE ETHERNET CONNECTIONS USING A ETHERNET HUB ETHERNET SYSTEM CONTROLLER RJ45 ETHERNET CONNECTOR ETHERNET SYSTEM CONTROLLER ONE SYSTEM CONTROLLER TWO
35
T2i R2i T1i R1i T1o R1o TELEPHONE LINE CONNECTION TERMINAL COLD WATER EARTH PIPE PRIMARY TELCO LINE OUT PRIMARY TELCO LINE RING AND TIP INPUT (T1i and R1i) SECONDARY TELCO LINE RING AND TIP INPUT (T2i and R2i)
36
N.C. ZONE CONTACT Z1 Z2 Z3 COM Z5 Z6 Z7 DR1 REX1 SEN1 DR2 REX2 SEN2
37
N.C. TAMPER 1K N.C. ZONE CONTACT Z1 Z2 Z3 COM Z5 Z6 Z7 DR1 REX1 SEN1 DR2 REX2 SEN2
38
B1+ B1- B2+ B2- P3 P4 CONNECTION SHOWN FOR BELL/SIREN 1 CP001:01 +-+- 12VDC SIREN WARNING DEVICE
39
B1+ B1- B2+ B2- P3 P4 CONNECTION SHOWN FOR CP001:03 1K5 OHM LED +12V AUX
40
350mA 700mA L H FIRE OVERRIDE FIRE OVERRIDE L H L H 350mA 700mA
41
N+ N- NA NB +12 0V TX RX RTS N+ N- NA NB AUX + - ACC-485 RS485 CONVERTOR SYSTEM CONTROLLER MODULE NETWORK CONNECTION SYSTEM CONTROLLER AUXILLARY TERMINALS USE SERIAL CABLE SUPPLIED WITH ACC-485 TO CONNECT TO THE PC SERIAL PORT
43
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT SINGLE LED READER CONTROL RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V PRX-NPROX NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION ORANGE IS NOT USED IN SINGLE LED OPERATION N.O. BUTTON
44
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT SINGLE LED READER CONTROL WITH BUTTON INPUT CONNECTION RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V PRX-NPROX NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION ORANGE IS USED FOR BUTTON INPUT CONNECTION N.O. BUTTON
45
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT YELLOW GREEN RED BROWN ORANGE +5V 0V CLOCK DATA OMRON READER MAGNETIC STRIPE READER TRACK 2 OUT COM IN INLINE +5V REGULATOR 50mA MAX OUTPUT PART CODE REG-5V +12V 0V CLOCK DATA CARD PRESENT REG-5V WIRING RED = INPUT (+9 TO +12V) COM = 0V WHITE = OUTPUT (+5V) IMPORTANT NOTE THE STANDARD OMRON/MAGTEK CARD READERS CAN HAVE AN INTERNAL MODIFICATION TO ALLOW THEM TO OPERATE FROM +12V WITHOUT THE INLINE REGULATOR AS SHOWN IN THIS DIAGRAM. PLEASE CONTACT ICT FOR FURTHER INFORMAITON. FOR THE CONNECTION OF OTHER MAGNETIC CARD DEVICES REFER TO MANUFACTURERS INSTALLATION MANUAL
46
+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT RED BLACK GREEN WHITE ORANGE BROWN BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER PRX-NANO NANO PROX PROXIMITY READER OR WIEGAND READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION FOR OTHER PROXIMITY READER CONNECTIONS REFER TO THE MANUFACTURERS INSTALLATION MANUAL 4 CORE CONDUCTOR BETWEEN READER AND CONTROLLER
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.