Best estimation of a local mass to diameter function using imaging probe and hot-wire TWC measurement Case of the AIRBUS imager during the Cayenne flight.

Similar presentations


Presentation on theme: "Best estimation of a local mass to diameter function using imaging probe and hot-wire TWC measurement Case of the AIRBUS imager during the Cayenne flight."— Presentation transcript:

1 Best estimation of a local mass to diameter function using imaging probe and hot-wire TWC measurement Case of the AIRBUS imager during the Cayenne flight 1423 C. Duroure, A. Delplanque (LaMP), M. Weber (AIRBUS) 1- We present a simple method to find the best mass to diameter function for a given sample set of hydrometeor images using as reference a alternate TWC measurement (in this case the hot wire Robust probe) 2- We compare the TWC estimation using this method with other methods (method using only the total count, methods using classical power law fit, method using estimation with more geometrical parameters (Lawson & Baker, JAMC,2006) 3- Examples of sampled images (capped columns) => simple geometrical model 4- Work in progress: Technical trouble: 1-Small particles PSD (D<100µm). Trouble in the ROI code ? 2-Sensibility of the results to the threshold rules (example of PSD with decreasing threshold) HAIC working document 18/11/2013 meeting

2 TWC hot wire (Robust) Best A.M estimate B Lawson & B. estimate Ctot estimate Three exemples of TWC estimations from imager using different rules, compared to hot wire probe. 1 2 3

3 12 3 Scatter plot (TWC from imager, TWC from hot wire probe) 1- Best estimation using power law functions (see next slides) 2- Lawson and Baker geometrical estimation f(A,W,L,P) (non linearity, due to Lmax estimation ?) 3- Simplest estimation (using total count of hydrometeor images) Comparisons between imager and hot wire probe

4 Sigma using only total concentration Best estimation using PSD and M(D) power law Beta=1.93 B=1.93B=1.50B=2.50 1- Look for the best linear correlation of TWC from imager and hot wire (not sensible to theA prefactor, i.e. calibration factors, DOF,….) => Estimation of B Estimation of the mass(diameter) function mass=A*Diam^B

5 Step 2- Look for the best PDF correlation between the two probes  Empirical estimation of the prefactor M= 3.28e-5 Dsur Step 3- Verify the estimated mass to diameter law (Mass=A.D B) assuming: shape model and hydrometeor density - Imager … Hot wire 1.93

6 Capped columns Leg [12 h,12.7 h] Best estimate of B=1.93 Irregular+agregates Leg [12.7 h,12.8 h] Best estimate of B=1.98 (more dense objects ?)

7 Some examples of « well oriented » images of capped columns (more than 300 avaiable (D> 300µm) for the 10.6 Km leg [12h,12.7h ] Manual estimation of 4 geometrical variables: (Lc,Wc) columns part, (Lp,Wp) plates part 1 mm Lc Wc Lp Wp Assumed growth historie of these CP: 1- Start as column for higth sursatuation S 2- Transition to plate for low S Large variability observed for this transition => Dificult to define a « standard » shape

8 Some examples of « irregular» images (+aggregates+rosettes) for the 10.6 Km altitude sub-leg [12.7 h,12.8h ] (« old » region, low concentration) 1 mm Assumed growth historie of these cristal ? 1- Nucleation of supercooled droplet 2- Vapour diffusion process (low S ?) 2- Agregation On the site: CATROI_V1423all Catalogue of all ROI images of size larger than 300µm (for identification of regions)

9 Tresholding sensibility analysis Treshold definition: Amp=(max(image)-min(image))/2 Med= min(image)+Amp Tresh=med-S*Amp Binary image= image LE Tresh S=0 S=0.1 S=0.2 S=0.25 GEO ROI files on the site V1423_GEO_S000 S=0 V1423_GEO_S010 S=0.1 --------------- V1423_GEO_S030 S=0.3

10 S=0 S=0.1 S=0.2 S=0.25 2 pix S=0 S=0.1 S=0.2 S=0.25 Tresholding sensibility analysis Small diameter effect Large diameter effect Diameter measure shift (few pixel) Artefact for tail of large particles

11 Technical trouble: 1-Small particles PSD (D<100µm). Trouble in the ROI code ? 2-AIRBUS PSD jump ? Diameter (µm) AIRBUS PSD __ ROI PSD ?