Waveguide for Station 5 M. Yoshida (Osaka Univ.).

Similar presentations


Presentation on theme: "Waveguide for Station 5 M. Yoshida (Osaka Univ.)."— Presentation transcript:

1 Waveguide for Station 5 M. Yoshida (Osaka Univ.)

2 Test assembly –450cm-long –Select better fiber canes External waveguide –290cm Internal waveguide –140cm Quality assessment has been done in Osaka Univ.

3 Fiber preparation - Population of measured fiber brightness - Cut fibers into 450cm canes Glue fibers on test cookies Photo of flash reflection LED trasmission 12 bad fibers rejected

4 Connector parts of waveguide for station 5 Bulkhead/Lead connector (1A / 2A) –1.10 mm drilling with countersunk hole on the back end (by G-Tech) 22-way connector (3A) –1.08 mm holes by 1.067 mm drill (AC precision) D0 connector –1.067 mm drilling (Fermilab) Flexible conduit –Adaptaflex PAFS21 and PAFS28 Heat shrink tube

5 External waveguide

6 Internal Waveguide 1400mm 1-20 21-42 43-64 65-86 87-108 109-128 1A1A1A1A 3A 3B 1 2 3 4 5 6 1-128

7 1 A Surface 1 - 20 1 - 22 1 - 20 3A Surface 1-1 1-2 1-3 1-4 1-5 1-6 Internal Connector ( 1 A, 3 A)

8 External Connector ( D0, 2 A) 1 2 3 4 5 6 7 8 121 122 123 124 125 126 127 128 2 A Surface D0 Surface

9 Mechanical strength of the external waveguide D0 connector boot and flexible conduit can be detached by pulling by hand Found that heat shrink tube at the connection does not have enough strength Epoxy glue at the connections, and then covered by heat shrink tube Also, we will find better heat shrink tube –Glue paint on inner wall of the tube

10 Flash light reflection - External waveguide - No fiber has reflection at D0 connector One fiber has reflection at lead connector end –Incomplete optical cement / Air bobble (?) –Damage of larger diameter fiber (?) –Need more careful treatment and feedback

11 Flash light reflection - Internal waveguide - All the fiber have no reflection light Slight damage on cladding layer of the 5 th 22-way connector The problem seems to be just on the surface Could be recovered by final polishing at Fermilab

12 Channel Assignment Inject light from a clear fiber to connector surface Scan injection point by hand Take movie Perfect assignment on all the connectors! camera waveguide fiber scan handy flash

13 LED transmission test - External waveguide - All the fiber have good transmission within 10% 10% #16 13170

14 LED transmission test - Internal waveguide - 10% All the fiber have good transmission within 10% 11914 (#87)

15 Summary The first production of external/internal waveguide show good transmission in all the channels. 3 bundle with test cookies have been delivered (675 fibers in total) –450 cm long Check bad fibers by Takatomi and Hideyuki, and send them back to G-Tech in this week. G-Tech will ship 5 sets of waveguides to Fermilab in the end of Feb. The fabrication process will be improved by: –Fixation by glue at the conduit connections –Better heat shrink tube with glue painted inside –More careful gluing on the connector surface –Strict rejection of larger diameter fiber