Download presentation
Presentation is loading. Please wait.
Published byNicholas Cross Modified over 9 years ago
1
PAVSYS PAVSYS ™ PAVSYS PAVSYS MODULAR ENGINEERED SUSTAINABLE HABITATS
2
PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS 450 CORE Slide each full length core section into the grooves cut in the flat panel surface...... Place the wall panel face down on a flat surface.....
3
PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS Form window opening by sliding each core section (in sequence) into the grooves cut in the flat panel surface...... 450 CORE 250.15 CORE 600.15 CORE 250.15 CORE 600.15 CORE 450 CORE Place the next wall panel face down on a flat surface.....
4
PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS Place each panel upright on the edge of the concrete floor slab......
5
500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS Place the adjoining panel with the window framing cores already fitted......
6
500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS Continue to place each panel until you complete one section......
7
500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 PAVSYS PAVSYS ™ PAVSYS PAVSYS Insert the steel locking plates to span adjoining panels and fit under the window openings......
8
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS Mount the steel rebar in the gaps between the cores and tie the overlaps......
9
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS Complete all the wall sections, then spray shotcrete over the rebar to create interlocking columns and beams......
10
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS EITHER: Continue to apply shotcrete to form an exterior coating finishing flush with the cores that frame the openings......
11
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS After the shotcrete has cured, remove the full depth cores and install the window and door frames......
12
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS OR: Alternatively fasten the horizontal sheeting to the mounting strips fixed to the concrete columns......
13
PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE PAVSYS EXT12CB24 500 CORE 600.15 CORE 250.15 CORE PAVSYS PAVSYS ™ PAVSYS PAVSYS Remove the full depth cores framing the openings and install the window and door frames......
14
PAVSYS PAVSYS ™ PAVSYS PAVSYS NOTE: To ensure correct core depths, exterior cladding options are selected at time of order...... www.pavilionsystems.com.auwww.pavilionsystems.com.auemail: info@pavilionsystems.com.auTelephone: 1-800-PAVSYS (1-800-728-797)info@pavilionsystems.com.au © COPYRIGHT – PAVILION SYSTEMS AUSTRALIA - 2013
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.