Presentation is loading. Please wait.

Presentation is loading. Please wait.

Survey Toolbox & Plume Detection Toolbox

Similar presentations


Presentation on theme: "Survey Toolbox & Plume Detection Toolbox"— Presentation transcript:

1 Survey Toolbox & Plume Detection Toolbox
ViSea-DAS Survey Toolbox & Plume Detection Toolbox (Introduction) Jeroen Aardoom Aqua Vision BV

2 Theoretical introduction Practical data acquisition & calibration

3 ADCP measures: water velocity

4 ADCP measures: water velocity

5 ADCP measures: water velocity

6

7 ADCP measures: Relative Backscatter (echo strength)

8 ADCP measures: Relative Backscatter Provides: spatial overview

9

10 ADCP measures: Relative Backscatter Provides: spatial overview

11 ADCP measures: Relative Backscatter Provides: spatial overview 3-D

12 ADCP measures: Relative Backscatter Provides: spatial 3D overview Disadvantage: qualitative, no SSC (mg/l)

13 The Challenge: Quantify SSC, in Real-Time Correct for signal losses: range&instrument normalization water absorption sediment absorption

14 The working equation (Deines)
Sv normalized backscatter [dB] C constant [dB] TT temperature of the transducer [°K] R slant range along the beam [m] L transmit pulse length [m] PT transmit power [W] aw water absorption [dB/m] as particle attenuation [dB/m] Kc RSSI scale factor [dB/count] E echo intensity [count] Er received noise [count]

15 VISEA-DAS Survey & Plume Detection Toolbox

16 Survey & Plume Detection Toolbox
VISEA-DAS Survey & Plume Detection Toolbox Converts backscatter to SSC Acquires the data Real Time All data within 1 format & timestamp

17 Survey & Plume Detection Toolbox
VISEA-DAS Survey & Plume Detection Toolbox ViSea-DAS

18 Survey & Plume Detection Toolbox
VISEA-DAS Survey & Plume Detection Toolbox Survey & Plume Detection Toolbox

19 Correlation / calibration
OBS Raw data : Volt/Ampere Is converted -> NTU water samples calibration -> SSC mg/l ADCP Raw data : Relative Backscatter Is converted -> Absolute Backscatter

20 Correlation / calibration
Onboard vessel / Real Time OBS (NTU) ADCP (IdB) Calibration

21 Calibration Sensor Setup

22

23

24

25 Typical sample/measuring scheme
3 Profile/calibration measurements Cross section/Transects measurements

26 Typical sample/measuring scheme
3 Profile/calibration measurements

27

28 Typical sample/measuring scheme
3 Profile/calibration measurements

29 Correlation / calibration
Onboard vessel / Real Time OBS (NTU) ADCP (IdB) Calibration

30 Typical sample/measuring scheme
Every hour  3 Profile/calibration measurements

31

32

33 Typical sample/measuring scheme
3 Profile/calibration measurements

34 Correlation / calibration
Post processing / analysis Samples (mg/l) Calibration Calibration OBS (NTU) ADCP (IdB) Cross validation

35 Every hour  3 Profile measurements

36

37

38

39

40

41

42

43

44 Estuary - hourly calibration
Every hour  3 Profile measurements Transect measurements

45


Download ppt "Survey Toolbox & Plume Detection Toolbox"

Similar presentations


Ads by Google