Packaged Rooftop Air Conditioning Unit Presents the
2
Packaged Rooftop The Eco2 is a packaged rooftop air conditioner available in 10 models ranging size from 50-65 tons (12,000-27,000 cfm). The packaged rooftop is a self-contained packaged air conditioning unit consisting of an outdoor air handling section including DX cooling coils, filters, supply and exhaust fans, motors, controls, and a condensing section including scroll compressors, air-cooled condenser and all interconnecting piping. This product is positioned to serve the commercial rooftop market - 1-4 story office buildings, retail stores, schools, warehouses and manufacturing.
3
Name Event Date Name Event Date 3 Standard Features HFC-407C refrigerant ASHRAE 90.1 level energy efficiencies Scroll compressors Double-wall construction Hinged access doors on both sides of the unit Double-sloped stainless steel drain pan Class II centrifugal-type forward-curved fan with 4” ESP capable Single-point power ETL listed Rated in accordance with ARI 360 Hot gas bypass on VAV units Terminal strip for field control connections 1” supply fan spring isolation 2” throwaway filters in an angled filter rack Bottom supply & return openings Painted exterior capable of withstanding a minimum of 500 hours of salt spray testing
4
Name Event Date Name Event Date 4 Control Features OptiLogic TM rooftop unit controller 4 line x 20 character clear language display System alarm LED Operating data, configuration, setpoints, service, setup and history accessible through keypad. Factory-tested and configured with automated run tester OptiLogic TM Control Center OPERATION DATA UNIT STATUS CONFIGURATION UNIT SETUP SERVICESETPOINTS HISTORY *** UNIT STATUS *** Supply Fan System Fan Status = ON Cntrl Output = 78% CANCEL BACK NEXT CHANGE ENTER SYSTEM ALARM
5
Name Event Date Name Event Date 5 Control Features (cont’d) Battery backed time clock 108 user defined parameters that can be displayed or set through display Five smoke purge modes (with power exhaust) Occupied/unoccupied switching Modem card for remote monitoring Expandable IO Self diagnostics Anti-short cycle delays for compressors and fan motors Energy saver delay Emergency stop input
6
Name Event Date Name Event Date 6 Standard Accessories Standard 14” full perimeter roof curb Standard 14” open condenser roof curb Compressor sound blankets Display remote mounting kit
7
Name Event Date Name Event Date 7 Factory-Installed Control Options Control Options Terminal strip (default) Zone sensor Thermostat analog input Standalone BACNet interface Master-slave configuration LON (in development)
8
Name Event Date Name Event Date 8 Factory-Installed Air Flow Options Air Flow Options Constant volume (default) VAV units - VFD VFD manual bypass 2” fan spring isolation Seismic restraints for supply fan Select horizontal supply and return air openings
9
Name Event Date Name Event Date 9 Factory-Installed Power Wiring Options Power Wiring Options Single-point power supply with manual disconnect switch Dual-point power supply GFCI convenience outlet
10
Name Event Date Name Event Date 10 Factory-Installed Coil Options Coil Options Pre-coated fins Post-coated coils Copper fins Left or right-hand drain pan connection
11
Name Event Date Name Event Date 11 Factory-Installed IAQ Options IAQ Options Dry bulb, single or comparative enthalpy economizer Air flow measurement CO2 demand ventilation Modulating damper Two-position damper Manual fixed damper Filter maintenance alarm
12
Name Event Date Name Event Date 12 Factory-Installed Filter Options Filter Options 2” pleated high efficiency 2” cleanable 2” carbon filters 12” rigid 65% efficiency, 2” prefilters 12” rigid 95% efficiency, 2” prefilters Rigid filter rack, no media for field-supplied filters
13
Name Event Date Name Event Date 13 Factory-Installed Refrigerant System Options Refrigerant System Options Hot gas bypass Replaceable core driers Shutoff valves Suction and discharge pressure transducers Low ambient operation High ambient operation (with pressure transducer package)
14
Name Event Date Name Event Date 14 Factory-Installed Motor Options Motor Options Multiple motor sizes Standard efficiency ODP High efficiency ODP Standard efficiency TEFC High efficiency TEFC
15
Name Event Date Name Event Date 15 Factory-Installed Relief Options Building Relief Options Barometric Powered exhaust on/off OA damper control Building pressure control Modulating exhaust Discharge damper VFD
16
Name Event Date Name Event Date 16 Unit Configuration Condensing Section Evaporator Filter Economizer Relief Hood Supply Fan Section Outside Air Hood Discharge Plenum Power Exhaust
17
Name Event Date Name Event Date 17 Competitive Comparisons 25-130 tons
18
Name Event Date Name Event Date 18 Capacities
19
Name Event Date Name Event Date 19 Weights
20
Name Event Date Name Event Date 20 Footprint
21
Name Event Date Name Event Date 21 Face Velocities
22
Name Event Date Name Event Date 22 The YORK Advantage Higher energy efficiency Alternative refrigerant HFC-407C IAQ capabilities Double-wall construction Factory packaged controls