1
Adaptive Power Shifting in Server Systems Ming Chen Xue Li
2
Introduction Power is one of the most important resources in data centers. CPU and main memory are two of the largest power gluttons. 85.4% 92.2% CPU & memCPU : mem 1.21 0.69
3
Motivation Power is a limited and precious resource for a server. CPU is NEITHER the only, NOR the largest consumer. Power needs to be controlled within a budget. Workload is varying in data centers. Over-provisioning may cause unnecessary cost. Power needs to be optimally allocated among server components, i.e., CPU and main memory. Goal: 1. Power control in the server-level. 2. Optimized allocation between CPU and main memory.
4
State of The Art Power control for CPU [Wang] in ISCA’09, main memory [Diniz] in ISCA’07 − Single component; Power control for servers [Lefurgy] in ICAC’07 − Assuming CPU is the major consumer Power shifting in server-level [Felter] in ICS’05 − Power is not controlled at the budget. − Performance is not optimal. Power control for racks [Wang] in HPCA’08, data centers [Wang] in PACT’09 − Complimentary to that work − Compose a complete power management scheme for data centers.
5
Who is Waiting? CPU mem CPU mem CPU mem CPU mem CPU mem CPU mem CPU is waiting.Memory is waiting.Coordinated. CPU: DVFS Memory: active memory size -> bandwidth
6
CPU-intensive workload Power should be shifted to CPU as much as possible. f opt = f max Memory-intensive workload Power should be shifted to memory as much as possible. f opt = f min Memory-intensive workload. f opt = ? What is the optimal allocation? For any piece of codes, it belongs to one of the following cases:
7
Proposed Solution − Ratio of the two weights: Memory Access Rate (MAR) − Optimization Weights the # of dispatched instructions in each control period the # of memory access requests in each control period Intuition − The more the # of activities is, the more power is required. Problems − MAR can guarantee the optimal allocation? − The weight ratio should be a function of MAR? Solution: − Power is controlled at the budget.
8
Schedules Idea verification (by the end of Sept) − Simulators integration; −Preliminary experiments to show the idea works; Controller design and tuning (by Oct 20) − Refinement of the idea − Refinement of sleeping scheme − Experiment plan Experiments and paper writing (until middle of Nov)