Presentation is loading. Please wait.

Presentation is loading. Please wait.

COCHRAN EMC-20H w/Helium

Similar presentations


Presentation on theme: "COCHRAN EMC-20H w/Helium"— Presentation transcript:

1 COCHRAN EMC-20H w/Helium
CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H w/Helium DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright All rights reserved, Protected under one or more Patents, Patents Pending, or Trademarks.

2 PLEASE SELECT THE PRESENTATION
YOU WOULD LIKE TO VIEW FROM THE BUTTONS BELOW. 1-BLEND TRIMIX 3-BLEND TRIMIX 1-PO2 W/TRIMIX DILUENT 2-PO2 W/TRIMIX DILUENT EXIT

3 PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

4 Locate the three side contacts.
TURN ME ON SIDE CONTACTS: Locate the three side contacts. Contact #3 Contact #2 Contact #1

5 TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER.
SIDE CONTACTS: Contact #3 Contact #2 Contact #1

6 THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. SIDE CONTACTS: Contact #3 Contact #2 Contact #1

7 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. Contact #2 Contact #1 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

8 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”
ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-TEST WHEN SUCCESSFULLY COMPLETED.

9 ALTITUDE APPEARS IN ASCENT BAR GRAPH
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 2 bars = ) ALTITUDE APPEARS IN ASCENT BAR GRAPH

10 THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. MAIN SCREEN THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. ALTERNATE SCREEN

11 (Repetitive Dive Number)
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Maximum Depth (of the last dive)

12 ALTERNATE SURFACE INTERVAL SCREEN WITH
RESIDUAL NITROGEN O2% (of Default Blend) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

13 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

14 LET’S GO DIVING

15 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

16 CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

17 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY
TO READ DISPLAY.

18 MAIN SCREEN VISIBLE DURING A DIVE
Note NDC Legend Ascent Rate (4 bars = fpm) NDC Time Remain (Time you can stay at current depth without Decompression) Water Temperature Bottom Time (so far this dive) Current PO2 Current Depth

19 ALTERNATE SCREEN THAT MAY BE
VIEWED DURING A DIVE O2% (of Current Blend) Helium Indicator CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

20 THE REMAIN TIME NUMBERS FLASH
A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES WRONG SLIDE AN AUDIBLE ALARM WILL BE ISSUED

21 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

22 DECOMPRESSION MODE COCHRAN DOES NOT INTEND FOR THIS
UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS.

23 DECOMPRESSION MODE WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE.

24 DECOMPRESSION MODE THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

25 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.
NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Note NDC Legend Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Decompression Time Note DEC Legend

26 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.
Water Temperature Note TEMP Legend Deco Ceiling Note CEIL Legend Don’t go above this depth for optimum Decompression

27 IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES.
NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Deco Ceiling

28 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION
(Of current Blend) Water Temperature CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

29 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.
THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.

30 DISPLAYED DATA (Post Dive Interval and Surface Interval) Dive of “Day”
(Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last Dive) Surface Time (Amount of time since last Dive) Maximum Depth (of the last Dive)

31 NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT PROGRAMMING IS DISABLED.

32 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES.
THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

33 TOUCH CONTACT PROGRAMMING MODE
CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

34 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H.
IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SEVEN PROGRAMMING MENUS.

35 THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

36 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

37 THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.
(Depth Alarm set to 124 feet)

38 THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU.
Conservatism set to 15%

39 THE FIFTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING BLEND #1 O2%.
O2 set to 16.0%

40 THE SIXTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING BLEND #1 HELIUM %.
Helium set to 70.0%

41 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU.
On Time set to 10 seconds

42 THE EIGHTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

43 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

44 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

45 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

46 (Based on Default Blend Set Point)
THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. Predict NDC Time (Time you can Stay at predict Depth Without Decompression) Calculated PO2 (Based on Default Blend Set Point) Predict Depth AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

47 BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.
PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

48 BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN.
Mode Blend Indicator (F1 = 1 FO2) CNS Oxygen Toxicity in % Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

49 TAPPING ON THE UNIT’S FACE ACCESSES THE ALTERNATE DISPLAY
Oxygen % of Default Blend Helium % of Default Blend Nitrogen % of Default Blend THE ALTERNATE INFORMATION SCREEN GIVES DATA REGARDING OXYGEN, HELIUM AND NITROGEN PERCENTAGES OF THE DEFAULT BLEND.

50 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.
The Digit being Programmed will Flash Until it is set and you Move on to the next Digit. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

51 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.
The Digit being Programmed will Flash

52 A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

53 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

54 SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS….. IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

55 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%

56 A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE O2% IN BLEND #1.

57 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN THE BLEND #1 FROM 5.0 TO 99.9%.
O2% set to 16.0%

58 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM % OF BLEND #1.

59 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN BLEND #1 FROM 0.0 TO 95.0%.
Helium set to 70.0%

60 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

61 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

62 A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. On Time set to 10 seconds A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

63 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.
Logbook Dive Number THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 1024 DIVES.

64 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. Hour 00 to 24 Minutes 00 to 59 Day Month Year THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

65 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

66 MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

67 PRIMARY LOGBOOK SCREEN
FOR A NORMAL DIVE NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) Water Temperature (Minimum recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

68 ALTERNATE LOGBOOK SCREEN
FOR A NORMAL DIVE O2% (Default Blend) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

69 PRIMARY LOGBOOK SCREEN
FOR A DECO DIVE DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) Deepest Deco Ceiling (Recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

70 ALTERNATE LOGBOOK SCREEN
FOR A DECO DIVE O2% (Default Blend) Water Temperature (Minimum recorded during the dive) CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

71 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

72 A COMPLETE COPY OF THE OWNER’S MANUAL
CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”

73 VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE
COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.

74 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!
Click on the door to go back to the main selection screen or click on the stop sign to exit.

75 PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE THREE GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

76 Locate the three side contacts.
TURN ME ON SIDE CONTACTS: Locate the three side contacts. Contact #3 Contact #2 Contact #1

77 TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER.
SIDE CONTACTS: Contact #3 Contact #2 Contact #1

78 THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. SIDE CONTACTS: Contact #3 Contact #2 Contact #1

79 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. Contact #2 Contact #1 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

80 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”
ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-TEST WHEN SUCCESSFULLY COMPLETED.

81 ALTITUDE APPEARS IN ASCENT BAR GRAPH
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 2 bars = ) ALTITUDE APPEARS IN ASCENT BAR GRAPH

82 THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. MAIN SCREEN THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. ALTERNATE SCREEN

83 (Repetitive Dive Number)
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Maximum Depth (of the last dive)

84 ALTERNATE SURFACE INTERVAL SCREEN WITH
RESIDUAL NITROGEN O2% (of Default Blend) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

85 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

86 LET’S GO DIVING

87 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

88 CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

89 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY
TO READ DISPLAY.

90 MAIN SCREEN VISIBLE DURING A DIVE
Note NDC Legend Ascent Rate (4 bars = fpm) NDC Time Remain (Time you can stay At current depth without Decompression) Water Temperature Bottom Time (so far this dive) Current PO2 Current Depth

91 ALTERNATE SCREEN THAT MAY BE
VIEWED DURING A DIVE O2% (of Current Blend) Helium Indicator CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

92 THE REMAIN TIME NUMBERS FLASH
A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES WRONG SLIDE AN AUDIBLE ALARM WILL BE ISSUED

93 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

94 DECOMPRESSION MODE COCHRAN DOES NOT INTEND FOR THIS
UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS.

95 DECOMPRESSION MODE WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE.

96 DECOMPRESSION MODE THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

97 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.
NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Note NDC Legend Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Decompression Time Note DEC Legend

98 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.
Water Temperature Note TEMP Legend Deco Ceiling Note CEIL Legend Don’t go above this depth for optimum Decompression

99 IN THIS EXAMPLE, THE DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES.
NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Deco Ceiling

100 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION
(of current Blend) Water Temperature CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

101 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.
THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.

102 DISPLAYED DATA (Post Dive Interval and Surface Interval) Dive of “Day”
(Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last Dive) Surface Time (Amount of time since last Dive) Maximum Depth (of the last Dive)

103 NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT PROGRAMMING IS DISABLED.

104 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES.
THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

105 TOUCH CONTACT PROGRAMMING MODE
CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

106 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H.
IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.

107 THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.
WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

108 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

109 THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.
(Depth Alarm set to 124 feet)

110 THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%

111 THE FIFTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING BLEND #1 O2%.
O2 set to 16.0%

112 THE SIXTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING BLEND #1 Helium %.
Helium set to 70.0%

113 THE SEVENTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING BLEND #2 O2%.
Blend #2 set to 36.0% O2

114 THE EIGHTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING BLEND #2 Helium %.
set to 30.0%

115 THE NINTH TOUCH BRINGS UP THE dEC b, BLEND #2 TIME BENCHMARK MENU.
Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?

116 THE NEXT TOUCH BRINGS UP THE dEC d, BLEND #2 DEPTH BENCHMARK MENU.
Benchmark set to 20 feet SO WHAT IS A BENCHMARK ?

117 THE NEXT TOUCH BRINGS UP THE O2 3 MENU FOR SETTING BLEND #3 O2%.
Blend #3 set to 86.0% O2

118 THE NEXT TOUCH BRINGS UP THE HE 3 MENU FOR SETTING BLEND #3 Helium %.
set to 30.0%

119 THE NEXT TOUCH BRINGS UP THE dEC d3, BLEND #3 DEPTH BENCHMARK MENU.
Deco Blend Depth Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?

120 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU.
On Time set to 10 seconds

121 THE NEXT TOUCH BRINGS THE LOG LOGBOOK MENU.

122 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

123 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

124 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

125 (Based on Default Blend Set Point)
THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. Predict NDC Time (Time you can stay At predict depth without Decompression) Calculated PO2 (Based on Default Blend Set Point) Predict Depth AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

126 BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.
PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

127 BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN.
Mode Blend Indicator (F2 = 2 FO2) CNS Oxygen Toxicity in % Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

128 TAPPING ON THE UNIT’S FACE ACCESSES THE ALTERNATE DISPLAY
Oxygen % of Default Blend Helium % of Default Blend Nitrogen % of Default Blend THE ALTERNATE INFORMATION SCREEN GIVES DATA REGARDING OXYGEN, HELIUM AND NITROGEN PERCENTAGES OF THE DEFAULT BLEND.

129 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.
The Digit being Programmed will Flash Until it is set and you Move on to the next Digit. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

130 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.
The Digit being Programmed will Flash

131 A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

132 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.

133 SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS….. IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

134 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%

135 A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE O2% IN BLEND #1.

136 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN BLEND #1 FROM 5.0 TO 99.9%.
O2 set to 16.0%

137 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM % OF BLEND #1.

138 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN BLEND #1 FROM 0.0 TO 95.0%.
Helium set to 70.0%

139 THE NEXT 1 & 2 COIN TOUCH WILL END BLEND #1 O2% SETTING AND BRING UP THE O2 2 MENU WHERE YOU SET THE O2% FOR BLEND #2.

140 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN BLEND #2 FROM 5.0 TO 99.9%.
Blend #2 set to 36.0%

141 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 2.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM % OF THE DECO BLEND.

142 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN BLEND #2 FROM 0.0 TO 95.0%.
Blend #2 Helium set to 30.0%

143 WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET BLEND #2 TIME BENCHMARK FROM 0 TO 999 MINUTES Blend #2 Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?

144 THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE BLEND #2 DEPTH BENCHMARK.

145 FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE BLEND #2 DEPTH BENCHMARK FROM 0 TO 320 FEET.
set to 20 feet SO WHAT IS A BENCHMARK ?

146 THE NEXT 1 & 2 COIN TOUCH WILL END BRING UP THE O2 3 MENU WHERE YOU SET THE O2% FOR THE BLEND #3.

147 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN BLEND #3 FROM 5.0 TO 99.9%.
Blend #3 set to 86.0%

148 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 3.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM % OF BLEND #3.

149 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN BLEND #3 FROM 0.0 TO 95.0%.
Blend #3 Helium set to 30.0%

150 THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d3 MENU WHERE YOU WILL BE ABLE TO CHANGE BLEND #3 DEPTH BENCHMARK.

151 FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE BLEND #3 DEPTH BENCHMARK FROM 0 TO 320 FEET.
set to 20 feet SO WHAT IS A BENCHMARK ?

152 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

153 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

154 A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. On Time set to 10 seconds A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

155 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.
Logbook Dive Number THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES.

156 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. Hour 00 to 24 Minutes 00 to 59 Day Month Year THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

157 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

158 MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

159 PRIMARY LOGBOOK SCREEN
FOR A NORMAL DIVE NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) Water Temperature (Minimum recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

160 ALTERNATE LOGBOOK SCREEN
FOR A NORMAL DIVE O2% (Default Blend) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

161 PRIMARY LOGBOOK SCREEN
FOR A DECO DIVE DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) Deepest Deco Ceiling (Recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

162 ALTERNATE LOGBOOK SCREEN
FOR A DECO DIVE O2% (Default Blend) Water Temperature (Minimum recorded during the dive) CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

163 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

164 A COMPLETE COPY OF THE OWNER’S MANUAL
CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”

165 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!
Click on the door to go back to the main selection screen or click on the stop sign to exit.

166 WHAT ARE BENCHMARKS? BENCHMARKS ARE CONDITIONS THAT MUST BE SATISFIED BEFORE THE GAS SWITCH FROM THE DEFAULT BLEND TO THE DECO BLEND WILL OCCUR. THE “Dec b” BENCHMARK IS THE BOTTOM TIME OF THE DIVE AFTER WHICH THE GAS SWITCHING WILL BE ENABLED. ONCE THE PROGRAMMED TIME HAS BEEN SATISFIED, THE GAS SWITCH WILL BE CONTROLLED BY DEPTH THE “Dec d” BENCHMARK IS THE DEPTH OF THE GAS SWITCH. ONCE THE DIVER ASCENDS ABOVE THE PROGRAMMED DEPTH, THE GAS SWITCH FROM THE DEFAULT BLEND TO THE DECO BLEND WILL OCCUR. IF BENCHMARK “Dec b” IS NOT SATISFIED THERE WILL NOT BE A GAS SWITCH. Click here to return to Touch Contact Programming Return

167 PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

168 Locate the three side contacts.
TURN ME ON SIDE CONTACTS: Locate the three side contacts. Contact #3 Contact #2 Contact #1

169 TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER.
SIDE CONTACTS: Contact #3 Contact #2 Contact #1

170 THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. SIDE CONTACTS: Contact #3 Contact #2 Contact #1

171 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. Contact #2 Contact #1 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

172 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”
ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-TEST WHEN SUCCESSFULLY COMPLETED.

173 ALTITUDE APPEARS IN ASCENT BAR GRAPH
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 2 bars = ) ALTITUDE APPEARS IN ASCENT BAR GRAPH

174 THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. MAIN SCREEN THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. ALTERNATE SCREEN

175 (Repetitive Dive Number)
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Maximum Depth (of the last dive)

176 ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN
PO2 in ATA (Default Blend Set Point) CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

177 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

178 LET’S GO DIVING

179 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

180 CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

181 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY
TO READ DISPLAY.

182 MAIN SCREEN VISIBLE DURING A DIVE
Note NDC Legend Ascent Rate (1 bar = fpm) NDC Time Remain (Time you can stay At current depth without Decompression) Water Temperature Bottom Time (so far this dive) Current FO2 Current Depth

183 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE
PO2 in ATA (of current Blend Set Point) CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

184 THE REMAIN TIME NUMBERS FLASH
A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES WRONG SLIDE AN AUDIBLE ALARM WILL BE ISSUED

185 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

186 DECOMPRESSION MODE COCHRAN DOES NOT INTEND FOR THIS
UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS.

187 DECOMPRESSION MODE WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE.

188 DECOMPRESSION MODE THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

189 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.
NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Note NDC Legend Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Decompression Time Note DEC Legend

190 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.
Water Temperature Note TEMP Legend Deco Ceiling Note CEIL Legend Don’t go above this depth for optimum Decompression

191 IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES.
NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Deco Ceiling

192 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION
PO2 in ATA (of current Blend Set Point) Water Temperature CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

193 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.
THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.

194 DISPLAYED DATA (Post Dive Interval and Surface Interval) Dive of “Day”
(Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last Dive) Surface Time (Amount of time since last Dive) Maximum Depth (of the last Dive)

195 NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT PROGRAMMING IS DISABLED.

196 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES.
THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

197 TOUCH CONTACT PROGRAMMING MODE
CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

198 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H.
IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE EIGHT PROGRAMMING MENUS.

199 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN.
FO2 SCREEN PO2 SCREEN THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE.

200 TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.
THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

201 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

202 THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.
(Depth Alarm set to 124 feet)

203 THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU.
Conservatism set to 15%

204 THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2.
Blend #1 set to 0.70 ATA

205 THE SEVENTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING THE DEFAULT BLEND O2%.
O2 set to 16.0%

206 THE EIGHTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING THE DEFAULT BLEND Helium %.
Helium set to 70.0%

207 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU.
On Time set to 10 seconds

208 THE TENTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

209 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

210 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

211 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

212 THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. Predict NDC Time (Time you can Stay at predict Depth Without Decompression) PO2 Set Point Predict Depth AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

213 BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.
PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

214 BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN.
Mode Blend Indicator (P1 = 1 PO2) CNS Oxygen Toxicity in % Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

215 TAPPING ON THE UNIT’S FACE ACCESSES THE ALTERNATE DISPLAY
Oxygen % of Default Blend Helium % of Default Blend Nitrogen % of Default Blend THE ALTERNATE INFORMATION SCREEN GIVES DATA REGARDING OXYGEN, HELIUM AND NITROGEN PERCENTAGES OF THE DEFAULT BLEND.

216 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.
The Digit being Programmed will Flash Until it is set and you Move on to the next Digit. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

217 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.
The Digit being Programmed will Flash

218 A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

219 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

220 SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS….. IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

221 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%

222 A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1
A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 IN THE DEFAULT BLEND.

223 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE PO2 OF THE DEFAULT BLEND FROM TO ATA. PO2 set to 0.70 ATA

224 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE OXYGEN PERCENTAGE OF THE DEFAULT BLEND DILUENT.

225 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN THE DEFAULT BLEND DILUENT FROM TO 99.9%. O2 set to 16.0%

226 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM PERCENTAGE OF THE DEFAULT BLEND DILUENT.

227 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN THE DEFAULT BLEND DILUENT FROM TO 95.0%. Helium set to 70.0%

228 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

229 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

230 A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. On Time set to 10 seconds A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

231 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.
Logbook Dive Number THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES.

232 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. Hour 00 to 24 Minutes 00 to 59 Day Month Year THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

233 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

234 MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

235 PRIMARY LOGBOOK SCREEN
FOR A NORMAL DIVE NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) Water Temperature (Minimum recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

236 ALTERNATE LOGBOOK SCREEN FOR A NORMAL DIVE
PO2 in ATA (Default Blend Set Point) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

237 PRIMARY LOGBOOK SCREEN
FOR A DECO DIVE DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) Deepest Deco Ceiling (Recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

238 ALTERNATE LOGBOOK SCREEN FOR A DECO DIVE
PO2 in ATA (Default Blend Set Point) Water Temperature (Minimum recorded during the dive) CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

239 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

240 A COMPLETE COPY OF THE OWNER’S MANUAL
CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”

241 VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE
COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.

242 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!
Click on the door to go back to the main selection screen or click on the stop sign to exit.

243 PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.
THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE TWO PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

244 Locate the three side contacts.
TURN ME ON SIDE CONTACTS: Locate the three side contacts. Contact #3 Contact #2 Contact #1

245 TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER.
SIDE CONTACTS: Contact #3 Contact #2 Contact #1

246 THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. SIDE CONTACTS: Contact #3 Contact #2 Contact #1

247 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.
SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. Contact #2 Contact #1 A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

248 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”
ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-TEST WHEN SUCCESSFULLY COMPLETED.

249 ALTITUDE APPEARS IN ASCENT BAR GRAPH
AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 2 bars = ) ALTITUDE APPEARS IN ASCENT BAR GRAPH

250 THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.
UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. MAIN SCREEN THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. ALTERNATE SCREEN

251 (Repetitive Dive Number)
IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Maximum Depth (of the last dive)

252 ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN
PO2 in ATA (Default Blend Set Point) CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Battery Voltage (2.9 Volts)

253 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

254 LET’S GO DIVING

255 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

256 CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.
IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

257 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY
TO READ DISPLAY.

258 MAIN SCREEN VISIBLE DURING A DIVE
Note NDC Legend Ascent Rate (1 bar = fpm) NDC Time Remain (Time you can stay At current depth without Decompression) Water Temperature Bottom Time (so far this dive) Current FO2 Current Depth

259 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE
PO2 in ATA (of Current Blend Set Point) CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

260 THE REMAIN TIME NUMBERS FLASH
A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES WRONG SLIDE AN AUDIBLE ALARM WILL BE ISSUED

261 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

262 DECOMPRESSION MODE COCHRAN DOES NOT INTEND FOR THIS
UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS.

263 DECOMPRESSION MODE WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE.

264 DECOMPRESSION MODE THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

265 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.
NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Note NDC Legend Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Decompression Time Note DEC Legend

266 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.
Water Temperature Note TEMP Legend Deco Ceiling Note CEIL Legend Don’t go above this depth for optimum Decompression

267 IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES.
NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop) Deco Ceiling

268 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION
PO2 in ATA (of current Blend Set Point) Water Temperature CNS Oxygen Toxicity in % OTU Oxygen Toxicity in % Max Depth (of current dive)

269 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.
THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.

270 DISPLAYED DATA (Post Dive Interval and Surface Interval) Dive of “Day”
(Repetitive Dive Number) Time to Fly (Hours before safely flying) Air Temperature Bottom Time (of the last Dive) Surface Time (Amount of time since last Dive) Maximum Depth (of the last Dive)

271 NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT
SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT PROGRAMMING IS DISABLED.

272 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES.
THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

273 TOUCH CONTACT PROGRAMMING MODE
CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

274 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H.
IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.

275 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN.
FO2 SCREEN PO2 SCREEN THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE.

276 TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.
THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

277 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

278 THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.
(Depth Alarm set to 124 feet)

279 THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%

280 THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING DEFAULT BLEND PO2.
PO2 set to 0.70 ATA

281 THE SEVENTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING THE DEFAULT BLEND DILUENT O2%.
O2 set to 16.0%

282 THE EIGHTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING THE DEFAULT BLEND Helium %.
Helium set to 70.0%

283 THE NEXT TOUCH BRINGS UP THE PO2 2, DECO BLEND PO2 MENU.
Deco Blend set to 1.30 ATA

284 THE TENTH TOUCH BRINGS UP THE O2 1 MENU FOR SETTING DECO BLEND DILUENT O2%.
O2 set to 36.0%

285 THE ELEVENTH TOUCH BRINGS UP THE HE 1 MENU FOR SETTING DECO BLEND HELIUM %.
Helium set to 30.0%

286 THE TWELTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU.
Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?

287 THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU.
Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?

288 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU.
On Time set to 10 seconds

289 THE FIFTENTH TOUCH BRINGS THE LOG LOGBOOK MENU.

290 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

291 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.
EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

292 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

293 THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. Predict NDC Time (Time you can Stay at predict Depth Without Decompression) PO2 Set Point Predict Depth AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

294 BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.
PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

295 BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN.
Mode Blend Indicator (P2 = 2 PO2) CNS Oxygen Toxicity in % Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

296 TAPPING ON THE UNIT’S FACE ACCESSES THE ALTERNATE DISPLAY
Oxygen % of Default Blend Helium % of Default Blend Nitrogen % of Default Blend THE ALTERNATE INFORMATION SCREEN GIVES DATA REGARDING OXYGEN, HELIUM AND NITROGEN PERCENTAGES OF THE DEFAULT BLEND.

297 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.
The Digit being Programmed will Flash Until it is set and you Move on to the next Digit. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

298 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.
The Digit being Programmed will Flash

299 A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.
THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

300 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.

301 SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS….. IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

302 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%

303 A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 .
A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND 2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF ADDITIONAL CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 . A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 VALUE OF THE DEFAULT BLEND.

304 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE PO2 OF THE DEFAULT BLEND FROM 0.50 TO 1.50 ATA. PO2 set to 0.70 ATA

305 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, O2 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE OXYGEN PERCENTAGE OF THE DEFAULT BLEND DILUENT.

306 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN THE DEFAULT BLEND DILUENT FROM TO 99.9%. O2 set to 16.0%

307 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 1.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM PERCENTAGE OF THE DEFAULT BLEND DILUENT.

308 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN THE DEFAULT BLEND DILUENT FROM TO 95.0%. Helium set to 70.0%

309 THE NEXT 1 & 2 COIN TOUCH WILL END THE DEFAULT BLEND PO2 SETTING AND BRING UP THE PO2 2 MENU WHERE YOU SET THE PO2 FOR THE DECO BLEND.

310 SET YOUR DECO BLEND PO2 IN ATA ANYWHERE FROM 0.50 TO 1.50.
Deco Blend set to 1.30 ATA ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE O2 2 MENU WHERE YOU SET THE DECO DILUENT OXYGEN %.

311 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN THE DECO DILUENT FROM 5.0 TO 99.9%.
Deco Diluent O2 set to 36.0%

312 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, HE 2.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE HELIUM % OF THE DECO DILUENT.

313 FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE HELIUM % IN DECO DILUENT FROM 0.0 TO 95.0%.
Deco Diluent Helium set to 30.0%

314 WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET THE DECO BLEND TIME BENCHMARK FROM 0 TO 999 MINUTES Deco Blend Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?

315 THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND DEPTH BENCHMARK.

316 FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND DEPTH BENCHMARK FROM 0 TO 99 FEET.
set to 20 feet SO WHAT IS A BENCHMARK ?

317 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.
A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

318 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER
THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

319 A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.
THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. On Time set to 10 seconds A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

320 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.
Logbook Dive Number THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES.

321 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001
TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. Hour 00 to 24 Minutes 00 to 59 Day Month Year THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

322 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

323 MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE
OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

324 PRIMARY LOGBOOK SCREEN
FOR A NORMAL DIVE NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive fpm) Water Temperature (Minimum recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

325 ALTERNATE LOGBOOK SCREEN FOR A NORMAL DIVE
PO2 in ATA (Default Blend Set Point) Helium Indicator CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

326 PRIMARY LOGBOOK SCREEN
FOR A DECO DIVE DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive fpm) Deepest Deco Ceiling (Recorded during the dive) Bottom Time (of the dive) Surface Time (Amount of time since last dive) Maximum Depth (of the dive)

327 ALTERNATE LOGBOOK SCREEN FOR A DECO DIVE
PO2 in ATA (Default Blend Set Point) Water Temperature (Minimum recorded during the dive) CNS Oxygen Toxicity in % Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in %

328 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

329 A COMPLETE COPY OF THE OWNER’S MANUAL
CAN BE OBTAINED FROM OUR WEBSITE. VISIT FIRST CLICK ON “PRODUCT MANUALS.”

330 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!
Click on the door to go back to the main selection screen or click on the stop sign to exit.


Download ppt "COCHRAN EMC-20H w/Helium"

Similar presentations


Ads by Google