Presentation is loading. Please wait.

Presentation is loading. Please wait.

Www.natinst.com Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer.

Similar presentations


Presentation on theme: "Www.natinst.com Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer."— Presentation transcript:

1 www.natinst.com Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A)

2 www.natinst.com Presentation Outline  Design considerations  Hardware and software selection  Demo of sample measurement systems  Factors affecting accuracy  Parting thoughts  Design considerations  Hardware and software selection  Demo of sample measurement systems  Factors affecting accuracy  Parting thoughts

3 www.natinst.com Design Considerations  Define system requirements Classify application based on signal types (AI/AO/DIO/CTR or combination) Number of I/O channels Speed/accuracy Signal conditioning requirements Portability Scalability Backward compatibility with existing systems  Define system requirements Classify application based on signal types (AI/AO/DIO/CTR or combination) Number of I/O channels Speed/accuracy Signal conditioning requirements Portability Scalability Backward compatibility with existing systems

4 www.natinst.com Measurement System Components Physical phenomena (Temperature, pressure, etc.) Transducer Voltage current, resistance Signal conditioning PC with data acquisition Device + Measurement software wiring

5 www.natinst.com Signal Types and Conditioning Requirements

6 www.natinst.com Defining Requirements (cont’d.)  Number of I/O channels Low – DAQ board Medium –Higher channel DAQ board –Multiple DAQ boards High –SCXI-based system  Number of I/O channels Low – DAQ board Medium –Higher channel DAQ board –Multiple DAQ boards High –SCXI-based system

7 www.natinst.com Requirements (cont’d.) PC-4350 PCI-603x PC-611x PCI-5112 Speed vs. Accuracy

8 www.natinst.com Additional Considerations  Multifunction DAQ board vs. computer-based instrument  Does your system need portability? PCMCIA, PCI, AT, PXI, USB, FireWire, serial, parallel  Multifunction DAQ board vs. computer-based instrument  Does your system need portability? PCMCIA, PCI, AT, PXI, USB, FireWire, serial, parallel

9 www.natinst.com Software/Programming Interface  Interactive interface (ready to run) VirtualBench  Programmatic interface  LabVIEW LabWindows/CVI C++/Visual Basic/Delphi ActiveX controls  Interactive interface (ready to run) VirtualBench  Programmatic interface  LabVIEW LabWindows/CVI C++/Visual Basic/Delphi ActiveX controls

10 www.natinst.com DAQ Designer 99  Online system configuration tool www.natinst.com/daq/ddonline.htm  Online system configuration tool www.natinst.com/daq/ddonline.htm

11 www.natinst.com Demo VirtualBench and LabVIEW Interface

12 www.natinst.com Making Accurate Measurements  Signal resolution  Grounding issues  Line noise  Environmental factors  Calibration  Source impedance  Signal resolution  Grounding issues  Line noise  Environmental factors  Calibration  Source impedance

13 www.natinst.com Accuracy Issues (cont’d.)  Signal resolution Type of A/D Converter – 12-bit vs. 16-bit Gain setting  Grounding issues Differential Reference single ended Non-Referenced single ended  Signal resolution Type of A/D Converter – 12-bit vs. 16-bit Gain setting  Grounding issues Differential Reference single ended Non-Referenced single ended

14 www.natinst.com Accuracy Issues (cont’d.)  Line noise Use filtering to eliminate 50-60 Hz line noise  Environmental factors Use shielded cables Distance system from noise sources  Calibration Perform regular calibration  Source impedance High impedance sources can cause problems  Line noise Use filtering to eliminate 50-60 Hz line noise  Environmental factors Use shielded cables Distance system from noise sources  Calibration Perform regular calibration  Source impedance High impedance sources can cause problems

15 www.natinst.com Demo – Temperature Measurement

16 www.natinst.com Demo – Frequency Measurement

17 www.natinst.com Deploy the System  Stand-alone systems  “Executable” versions for clients  Part of networked DAQ system DataSocket RDA VI Server  Stand-alone systems  “Executable” versions for clients  Part of networked DAQ system DataSocket RDA VI Server

18 www.natinst.com Measure Anything / Automate Everything  PC-based measurement systems offer: Superior performance Lower cost Better integration Faster development cycles Distributed measurement capabilities  PC-based measurement systems offer: Superior performance Lower cost Better integration Faster development cycles Distributed measurement capabilities


Download ppt "Www.natinst.com Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer."

Similar presentations


Ads by Google