HBD HV Control and Monitoring System NOW @ PHENIX Manuel Proissl HBD Meeting 12/09/2008
2
OUTLINE Installation in PHENIX The completed procedure Mainframe Initialization OUR HV Control Time To Talk: “What Do We Want?” Forward/Reverse Bias Trip (Peak) Current for GEMs & Mesh P/T Correction Layers / Tables Coming Up Voltage / Current Calibration Relay Boards, Cabling, MF testing, … HVCV2.0 Distribution Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008 HBD HV Control & Monitoring System Manuel Proissl Page 2 of 6
3
INSTALLATION IN PHENIX December 8 th, 2008 – 4PM EST :: HBD HV Control & Monitoring System successfully installed in PHENIX Due to the HBD Simulation Project, the installation process without big complications! TS5 has been powered up and connected to the HBD mainframe on the bridge. The mainframe rack which is shared with the RXNP guys, has been powered up. ALL 6 Run9-modified 1471Ns, which have been crash tested and prepared for installation since last Thursday continuously day & night, were installed in the 1458HP mainframe. ALL 40 channels (GEMs & Mesh chn) have been ramped up and measured via Fluke by controlling them one by one through the HV Control System, which was run on a laptop connected to the PHENIX wireless. The installation channel check procedure automatically ramped & disabled channel by channel after measurement. The channel check has been completely successful!!! Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008 HBD HV Control & Monitoring System Manuel Proissl Page 3 of 6
4
INSTALLATION IN PHENIX Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008 Channel Check on the Bridge View onto the HBD from HV Bridge HBD HV Control & Monitoring System Manuel Proissl Page 4 of 6
5
OUR HV CONTROL :: FAQ! How do we want the HBD to operate? Operational & Standby Voltages Forward & Reverse Bias: dV is set manually by user for key voltages Trip Settings: GEMs (~165mkA?) and Mesh (~20mkA?) HV Control will be connected to the P/T database (update every 2min) and can so adjust operational/standby voltages based on layers WE need to set automatically! Questions? Ideas? Comments? Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008 HBD HV Control & Monitoring System Manuel Proissl Page 5 of 6
6
COMING UP Correction Curves for 1471N Calibration: this week! Relay Board Trip tests in the hall Simulating the HBD with load channel by channel Distribution / Installation Files for Linux & XP/Vista Platform independence Final installation files with Installation Wizard Expected Date Online: January 2 nd, 2009 HBD HV Control & Monitoring System Manuel Proissl Page 6 of 6 Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008