Presentation is loading. Please wait.

Presentation is loading. Please wait.

Energy and Carbon Performance of Housing: Upgrade Analysis, Energy Labelling and National Policy Development Joe Clarke, Cameron Johnstone, Jae-min Kim,

Similar presentations


Presentation on theme: "Energy and Carbon Performance of Housing: Upgrade Analysis, Energy Labelling and National Policy Development Joe Clarke, Cameron Johnstone, Jae-min Kim,"— Presentation transcript:

1 Energy and Carbon Performance of Housing: Upgrade Analysis, Energy Labelling and National Policy Development Joe Clarke, Cameron Johnstone, Jae-min Kim, Paul Tuohy Energy Systems Research Unit, University of Strathclyde

2 Simulation has the potential to underpin future legislative requirements of the EPBD. Scottish Building Standards Agency funded work to investigate national domestic stock upgrades and individual dwelling certification.

3 1.Stock: 2,278,000 dwellings with a high refurbishment requirement. 2.Dwelling types: detached, semi-detached, terraced, tenement (flats with shared access), four-in-a-block, tower block, conversions. 4.Construction system: cavity wall (72%), solid wall (28%). 3.Materials: brick/block (67%), sandstone (18%), whin/granite (4%), non-traditional (10%). 5.External finish: rendered (71%), stone (18%), brick (5%), non- traditional (5%). 6.Energy: dwellings comprise a high proportion of overall energy consumption  14.5 TWh/yr (5.5 MT CO 2 ) for heating against a total demand of 85 TWh/yr. Project context: Scotland

4 2. General  mean National Home Energy Rating is 4.1 (0 poor - 10 good)  need for energy efficiency improvements  fuel poverty, hypothermia, condensation and mould growth are concerns 1. Insulation and heating systems  80% have loft insulation (only 12% meet the 1991 building standards)  92% have hot water tank insulation (5% to an unacceptable level)  74% have pipe insulation (13% to an unacceptable level)  70% have gas central heating (14% are partial installations) Stock performance

5 Legislative questions  what upgrades offer best value?  what deployment combinations are suited to the different house/construction types?  how should the deployments be phased over time?  can simulation be used to answer such questions? Relevant upgrades  wall, floor, loft, tank and pipe insulation  draught-proofing  heating system and control improvements  double/advanced glazing  low energy lights and appliances  solar thermal/electric  wind energy  recovered heat EDEM model constructed by applying the ESP-r system to the national housing stock

6  Problematic because of the many permutations of house types, constructional systems and upgrade measures.  Easy to identify dwelling types from an architecture and construction (A/C) viewpoint, but …. dwellings belonging to the same A/C group may have different energy consumption (/m 2 ) due to dissimilar energy efficiency measures having been applied; dwellings corresponding to different A/C groups may have the same consumption because the governing design parameters are essentially the same.  => operate in terms of TCs not A/C types. EDEM: stock modelling

7  Assume thermodynamic classes (TC) where different A/C types may belong to the same TC.  There are 6,480 TCs each representing unique combination of 7 fabric and 6 system design parameters that may exist at several levels.  Determine the normalised energy performance of each TCs by simulation.  Relate existing or proposed dwellings to a TC via the present level of its governing design parameters.  Should any design parameters be changed as part of an upgrade then that house is deemed to have moved to another TC.  TCs therefore represent all possibilities now and in the future. Project method Dwelling model:  comprises living, eating and sleeping areas  has typical usage patterns, exposures and control set-points  has TC specific design parameters applied  is subjected to long term representative climate Simulation context may be varied to represent future scenarios (e.g. climate change or improved living standards).

8 universe of possible dwellings poor insulation low mass small windows leaky … well insulated high internal mass large windows well sealed … discrete designs 6,480 simulated models inherited behaviour TCs are unique combinations of construction parameters: insulation level (6) capacity level (2) capacity position (3) air permeability (3) window size (3) exposure (5) wall-to-floor ratio (2) and systems parameters: fuel type (5) plant type (8) plant efficiency (3) DHW (3) RES type (3) RES scale (3) giving 2 x 3,240 combinations representing the universe of possibilities.

9 Insulation: Infiltration : Glazed area: Capacity: Gains: Operation: Exposure: Hot water use: Heating system efficiency: poor ave high eco leaky ave tight Climate: Low carbon heating: std large low high low med frugal ave profl high std future high no med profl frugal ave high low med h-m UKCIP m-lavelow super Energy performance characterised by the appropriate combination of key parameters Energy efficiency lights: Appliances: Low carbon electricity: high no med all no med high low med high low med high low med Water heat sys efficiency: Emissions factors: EDEM: performance rating individual dwelling statement

10 Fabric loss (exp, ins): Infiltration: Glazed area: Capacity: Gains: Operation: Hot water use: Energy efficiency lights: Appliances: Low carbon electricity: Heating system efficiency: v.high high ave low leaky ave tight Climate: Low carbon heating: std large low std high no med high no med std all no med high low med std high low med Water heat sys efficiency: v.low Emissions factors: EDEM: performance rating, SAP emulation individual dwelling statement Options may be restricted to align with SAP 2005 assumptions

11 TC Parameters Regression equation coefficients a b c d e f g h i j k 1 1/0/2/2/0 -1.003 -0.008 -0.115 0.0097 0.0008 0.0052 -0.110 0 0.0009 0.0130 22.7 2 0/0/2/2/0 0.181 -0.015 -0.157 0.2350 -0.0020 0.0013 -0.190 0.00010 0.0030 0.0204 17.4 3 1/0/1/1/1 -0.946 -0.005 -0.106 -0.0080 0.0009 0.0044 -0.107 0 0.0006 0.0128 21.5 4 0/0/0/0/0 -0.755 -0.007 -0.100 -0.0940 0.0028 0.0012 -0.121 0 -0.0020 0.0171 22.9 5 0/0/0/1/0 -0.969 -0.009 -0.112 0.0387 0.0009 0.0052 -0.105 0 0.0010 0.0127 21.6 6 0/0/1/2/0 -0.889 -0.007 -0.098 0.0155 0.0007 0.0046 -0.096 0 0.0009 0.0130 19.7 7 1/1/1/0/0 -0.857 -0.011 -0.113 0.0048 0.0010 0.0054 -0.102 0 0.0007 0.0127 19.2 8 1/1/0/1/0 -0.854 -0.011 -0.112 0.0060 0.0010 0.0053 -0.102 0 0.0007 0.0127 19.1 9 1/0/0/0/2 -0.855 -0.011 -0.113 0.0064 0.0010 0.0054 -0.103 0 0.0007 0.0128 19.1 10 1/0/0/1/2 -0.856 -0.011 -0.114 0.0078 0.0010 0.0055 -0.104 0 0.0008 0.0129 19.2 11 1/0/1/2/2 -0.800 -0.010 -0.100 0.0093 0.0011 0.0048 -0.100 0 0.0008 0.0123 17.7 12 1/0/2/1/2 0.915 -0.013 -0.229 0.0491 -0.0060 0.0047 -0.220 0.00040 0.0081 0.0194 12.3 13 0/0/2/0/2 -0.685 -0.003 -0.086 0.0552 0.0007 0.0038 -0.083 0 0.0002 0.0105 14.5 14 0/0/1/1/2 -0.742 -0.005 -0.105 0.0579 0.0007 0.0053 -0.083 0 0.0007 0.0103 15.2 15 1/1/2/0/1 0.001 0.007 -0.113 -0.0240 -0.0020 0.0014 -0.072 0.00020 0 0.0096 11.0 16 1/2/2/2/0 -0.610 -0.003 -0.087 0.0602 0.0007 0.0043 -0.076 0 0.0008 0.0091 12.4 17 0/1/1/0/1 -0.610 -0.003 -0.087 0.0604 0.0007 0.0043 -0.076 0 0.0008 0.0091 12.4 18 0/1/1/2/1 -0.523 -0.009 -0.097 0.0134 0.0002 0.0051 -0.072 0 0.0006 0.0090 11.6 19 0/1/2/2/1 -0.557 -0.009 -0.096 0.0489 0.0005 0.0053 -0.071 0 0.0007 0.0090 11.5 20 1/1/1/1/2 -0.555 -0.009 -0.096 0.0487 0.0005 0.0052 -0.071 0 0.0007 0.0090 11.4 21 1/1/2/2/2 -0.196 -0.006 -0.092 -0.0190 -0.0010 0.0034 -0.063 0.00003 0.0013 0.0073 10.0 22 0/1/1/0/2 -0.469 -0.006 -0.084 0.0527 0.0005 0.0045 -0.070 0 0.0009 0.0085 9.7 23 1/2/1/2/0 -0.465 -0.009 -0.102 0.0130 0.0002 0.0053 -0.071 0 0.0006 0.0091 10.5 24 0/2/1/0/1 -0.396 -0.005 -0.088 0.0425 0.0001 0.0047 -0.068 0 0.0010 0.0080 8.7 25 0/1/0/1/2 -0.425 -0.007 -0.076 0.0547 0.0005 0.0042 -0.065 0 0.0094 0.0078 8.6 26 0/2/0/2/1 -0.389 -0.005 -0.086 0.0396 0.0001 0.0046 -0.066 0 0.0091 0.0078 8.6 27 1/2/0/2/2 -0.237 -0.009 -0.074 -0.0050 0 0.0040 -0.046 0.00004 0.0002 0.0063 6.0 28 1/2/1/0/2 -0.228 -0.009 -0.069 -0.0060 0 0.0038 -0.042 0.00004 0.0001 0.0058 5.6 29 0/2/0/0/2 -0.159 -0.005 -0.053 0.0079 0 0.0032 -0.036 0.00002 0.0004 0.0043 3.9 30 0/2/1/2/2 -0.157 -0.005 -0.052 0.0077 0 0.0031 -0.035 0.00002 0.0004 0.0043 3.9 E = a θ + b R d + c R f + dV + e θ R d + f θ R f + g θ V + h R d R f + i R d V + j R f V + k large windows, poor insulation, high capacity (externally located), high infiltration, …

12 Dwelling Type Detached Semi-detached Terrace Tenement flat 4-in-a-block As built As As As As built #1 built #1 built #2 built #1 Heating demand 43 71 43 87 41 81 34 66 30 (kWh m -2 y -1 ) TC model 13 30 18 28 13 29 21 11 26 TC heating 46 76 46 91 46 87 34 67 26 (kWh m -2 y -1 ) % difference 7 7 7 5 12 7 3 2 -13 #1: with double glazing, cavity and loft insulation and draught proofing. #2: with double glazing, internal insulation and draught proofing. EDEM validation (v. measured and full scale simulation)

13 EDEM validation (v. published NHER ratings)

14 Certificate and improvement advice Individual dwelling statement EDEM: application scale Individual dwelling EPBD rating and action plan generation EDEM Stock rating and upgrade strategy appraisal Scottish house condition survey CONTEXT policy, climate, fuel, demographics, economics

15 EDEM in use

16 EDEM in use: emissions label high insulation level:tight air leakage:new heating system:

17 current rating improved rating ENERGY CERTIFICATE improvement advice EDEM in use: energy certificate household questionnaire

18 EDEM application: national scale Date Type Pre 1919-65 (64%)1965-82 (25%)1982-02 (11%) CavitySolidNon-trad. Cavity | Solid CavitySolidNon-trad. Cavity | Solid Cavity Timber | Trad. Houses Detached4%5% 4% 0.5% 2% 2% 18% Semi-detached8%5% 4% 0.5% 1.5%1.5 21% Terraced8.5%3.5%0.50.5%6% 1.5% 1% 24% Flats Tenement6%9%1% 3% 0.5% 1% 23% Four-in-a-block6%2% 0.5% 10% Tower block1% 0.5% 1.5% 3% Conversion 2% Total (2.1 M)33.5% 26.5%2.5% 2% 17.5% 4.5%3.5%5.5% 100%0% 62% 38% Totals

19 TC assignment Date Type Pre 1919-65 (64%)1965-82 (25%)1982-02 (11%) CavitySolidNon-trad. Cavity | Solid CavitySolidNon-trad. Cavity | Solid Cavity Timber | Trad. Houses Detached62,1 6,7,17, 18 6, 182, 1926 17, 18 18% Semi-detached62, 1 6,7,17, 18 6, 182, 1926 17, 18 21% Terraced61, 2162 6,7,17, 18 6, 182, 1926 17, 18 24% Flats Tenement62, 162 6,7,17, 18 6, 182, 1926 17, 18 23% Four-in-a-block61, 262 6,7,17, 18 2, 19 10% Tower block6 6 6, 18 3% Conversion 1, 2 2% Total (2.1 M)33.5% 26.5%2.5% 2% 17.5% 4.5%3.5%5.5% 100%0% 62% 38% Totals

20 EDEM application: national scale Date Type Pre 1919-65 (64%)1965-82 (25%)1982-02 (11%) CavitySolidNon-trad. Cavity | Solid CavitySolidNon-trad. Cavity | Solid Cavity Timber | Trad. Houses Detached4%5% 4% 0.5% 2% 2% 18% Semi-detached8%5% 4% 0.5% 1.5%1.5 21% Terraced8.5%3.5%0.50.5%6% 1.5% 1% 24% Flats Tenement6%9%1% 3% 0.5% 1% 23% Four-in-a-block6%2% 0.5% 10% Tower block1% 0.5% 1.5% 3% Conversion 2% Total (2.1 M)33.5% 26.5%2.5% 2% 17.5% 4.5%3.5%5.5% 100%0% 62% 38% Totals

21 TC assignment Date Type Pre 1919-65 (64%)1965-82 (25%)1982-02 (11%) CavitySolidNon-trad. Cavity | Solid CavitySolidNon-trad. Cavity | Solid Cavity Timber | Trad. Houses Detached62,1 6,7,17, 18 6, 182, 1926 17, 18 18% Semi-detached62, 1 6,7,17, 18 6, 182, 1926 17, 18 21% Terraced61, 2162 6,7,17, 18 6, 182, 1926 17, 18 24% Flats Tenement62, 162 6,7,17, 18 6, 182, 1926 17, 18 23% Four-in-a-block61, 262 6,7,17, 18 2, 19 10% Tower block6 6 6, 18 3% Conversion 1, 2 2% Total (2.1 M)33.5% 26.5%2.5% 2% 17.5% 4.5%3.5%5.5% 100%0% 62% 38% Totals

22 EDEM in use

23 Current stock maps to 8 TCs: - TC6 - TC2 - TC1 - TC7 - TC17 - TC18 - TC19 TCDescription% of stockNumber of dwellings Floor area (m 2 ) Annual heating demand (kWh/m 2 ) 1 Solid wall, high thermal mass, large windows, poor insulation and large air change rate 11.5261,97022,461,00090 2 Solid wall, high thermal mass, standard windows, poor insulation and large air change rate 16.5375,87031,778,00087 6 Cavity wall, outer thermal mass, standard windows, poor insulation and large air change rate 42956,76083,283,00075 7 Cavity wall, inner thermal mass, large windows, standard insulation and large air change rate 7.25165,15515,934,00073 17 Cavity wall, inner thermal mass, standard windows, standard insulation and standard air change rate 8.25187,93518,087,00047 18 Cavity wall, outer thermal mass, standard windows, standard insulation and standard air change rate 11250,58023,810,00047 19 Solid wall, standard thermal mass, standard windows, standard insulation and standard air change rate 2.556,9505,159,00046 26 Timber wall, outer thermal mass, standard windows, high insulation and standard air change rate 122,7802,596,00026 Upgrade strategy

24 Existing TC % of stock % of annual heating demand ImprovementNew TC National heating demand reduction (TWh) (%) TC6 TC11 4243Air tightness to high standards TC110.674.6 Insulation to standard levels TC182.215.5 TC216.519Standard levels of draught proofing and insulation TC191.39 TC111.514High levels of draught proofing; standard levels of insulation TC211.28.7 TC77.258High levels of draught proofing and insulation TC2817 TC17 & TC18 19.2513.5High levels of draught proofing TC220.75 High levels of insulation TC240.96 High levels of draught proofing and insulation TC301.611 TC192.51.5High levels of draught proofing; standard levels of insulation TC210.060.4 TC upgrades may be phased: - TC6 to TC11 then to TC18 - TC18 to TC22/ TC24 then to TC30  12 TC relocations examined: 1 to 16 and 21 2 to 19 6 to 11, 18 and 30 7 to 28 17 to 22 and 24 18 to 30 19 to 21  5 relocations gave highest potential for space heating energy savings: 1 to 21 (62%) 2 to 19 (48%) 6 to 30 (90%) 7 to 28 (86%) 18 to 30 (80%) Upgrade strategy

25 Space heating impact, detached houses

26 Overall outcome: TC 6 to 30 for detached house

27 improvement advice EDEM application: regional scale

28  ESP-r system used to formulate EDEM for domestic sector upgrade appraisal.  The approach is widely applicable because the underlying TCs cover all possibilities, present and future.  EDEM is available under an Open Source license.  EDEM has been applied at national and regional levels. In the former case (i.e. for Scotland 14.5 TWh/y): Conclusions Phase 1 (TC6, TC2 & TC1) -4.7 TWh/y (32.4%) & 1.8 MT CO 2 + Phase 2 (TC7) - 5.7 TWh/y (39.3%) & 2.2 MT CO 2 + Phase 3 (TC17 & TC18) -7.3 TWh/y (50.3%) & 2.8 MT CO 2 + End of programme (TC19) -7.6 TWh/y (52.4%) & 2.8 MT CO 2