Presentation is loading. Please wait.

Presentation is loading. Please wait.

Basics & principles of mechanical ventilation g.k.kumar.

Similar presentations


Presentation on theme: "Basics & principles of mechanical ventilation g.k.kumar."— Presentation transcript:

1 Basics & principles of mechanical ventilation g.k.kumar

2 Basics & principles of ventilation -What is ventilator -How ventilators work -How to use ?

3 Ventilator: The Machine delivers O2 & removes Co2 with out harming the patient. The Ventilator should have capacity of delivering a consistent tidal volume under all adverse conditions of lung disease.

4 Mechanical Ventilation: The process / method by applying (intermittent) positive airway pressure & supplementation of Inspired O2 to achieve desirable oxygenation.

5 GOALS of Mechanical Ventilation:  Good ventilation (known by pa Co2)  Oxygenation (by pa O2).  Alveolar recruitment by peep  Lowest O2 supplement.  Synchrony between patient & Ventilation. & Safe  No Negative hemodynamic effect No Barotraumas No auto PEEP

6 Classification of Mechanical ventilation: Positive / Negative pressure ventilation. Partial / full ventilation. Invasive / Non invasive ventilation.

7 Components of ventilator 1. Power source-electrical/pneumatic/both 2. Control systems-circuits, control panel 3. Display systems

8 compr essor Insp. limb Exp.limb Pt blender oxy Central unit V V PFio2T Hum& neb

9 PHASES & VARIABLES INITIATION OF INSPIRATION-TRIGGER INSPIRATION-LIMIT MAINTENANCE OF INSPIRATION-CONTROL CHANGING TO EXPIRATION-CYCLE

10 Triggering variable: Triggering is a method of starting the inspiration Types: Pressure Triggering Flow Triggering - No lag time Time Triggering -Less effort

11 Control Variable: Setting that maintained thro ‘out inspiration Type : Volume control. Pressure control.

12 PCV VCV Vt. Variableset PIP SET & lesser variable & more Plateau pressure Set Variable Inspiratory flow decelerating type fixed flow type sinusoidal/square Inspiratory time setset Respiratory rate SetSet Barotrauma Less More Leak compensation +for minor leaknil Patients acceptance good -

13 Limit Variable: Setting that can't be exceeded during inspiration Type : Pressure limit- [psv] volume limit Flow limit

14 Cycle variable: Method of termination of inspiration, I.e. changing over from inspiration to expiration. Types: Volume cycle Pressure cycle Time cycle flow cycle.

15 VtPA range compliance ClCcw PAi PAe Raw Compliance-resistance-volume C=▲V /▲PR=[PIP-Pp] / F

16

17 Normal resistance Un intubated patient ; 0.6 - 2.4 cm H 2 0 / L / Sec,. at 0.5L /sec Intubated patient; 6cm H20 / L / Sec

18 Ventilatory controls-inter relation MV f Vt T Ti I:E Te

19 Ventilator Modes Combination of breath type and phase variable. Conventional modes Recent modes Newer modes CMVMMV VAPS, PAug A/C MV APRV VS, PRVC IMV & SIMVBIPAP AUTOFLOW CPAP & PEEP IRV AUTOMODE VCVDLV PAV,PPS PSV HFJV ASV

20 Controlled mechanical ventilation: -CMV All breaths are delivered by ventilator. No Patient participation. Set Vt. Delivered at set RR Requires sedation & neuromuscular blockade. Time initiated Volume limited Volume cycling

21 CMV Indications Patient with no efforts / complete respiratory failure. When negative inspiratory effort contra indicated. eg.flail chest. During anesthesia. Disadvantages Patient participation not allowed.  Heavy sedation relaxant – need  Long term CMV  Respiratory muscle weakness.  Varying PIP according to lung compliance & patient efforts.

22 Assist / Control Mechanical ventilation: Patient can trigger ventilation at a rate more than set RR All breaths are delivered at set volume, set time & set pressure Triggering  pressure / flow (spontaneous) Time (Mandatory) Limiting  Volume Cycling  Volume Patient can vary RR only but not vt.

23 Indications:  Patient with normal drive but with respiratory weakness  Recovering patient.  To preserve patient efforts  Weaning. Disadvantages  Rapid triggering  Hyperventilation Hypotension  Flow rare should be adjusted according to the need.  If RR < RR  CMV mode. Assist / Control Mechanical Ventilation

24 IMV / SIMV The patient receives the Mandatory set Vt at set RR. The set Mandatory breaths are synchronized with patient efforts. Between the mandatory breaths the patient can breath spontaneously Spontaneous breath vt depends on  Patients respiratory effort  PS  Triggering - Pressure Limiting - Volume Cycling - Time

25 IMV / SIMV Advantages: The mandatory breaths are synchronized with patient’s Spontaneous efforts. Hyperventilation is less More active participation of patient Disadvantages: More WOB

26 A/CMVSIMV Patient decides only RR patient effort decides RR &vt. Less WOB as only more WOB as Initiation by patient patient has to. operate demand. flow system Possibility of hyper ventilation No

27 CPAP: A mode is which positive pressure is applied tho’ out the respiratory cycle using during spontaneous ventilation. (Pr applied in mechanical ventilation :PEEP) No Ventilatory assistance Positive Pressure causes: Prevention of alveolar collapse & alveolar recruitment Î FRC & Atelecasis FlO2 requirement

28  CPAP PEEP Pr applied and base linePr. Applied with Pr elevated when ventilatory some ventilatory Assistance is nil. Assistance present.

29 PEEP Applied when Fio2 requirement is 50% - 60%. Best Peep: PEEP titrated to achieve optimal respiratory system compliance. Optimal Peep :Titration of PEEP until Qs /Qt is < 15 %

30 Volume Control Ventilation: Vt. Delivery is constant according to pressure regardless of changes in airway resistance or respiratory system compliance. VCV is given when constant MV is needed (eg, : patient with Î ICT)

31 Pressure control ventilation: The pressure applied to the airways is constant regardless of airway resistance and compliance. Constant pressure is delivered throughout inspiration at set RR Time initiated pressure limiting time cycling. Vt may vary according to patient lung conditions. PCV avoids over distention in patient with ALI, because PIP can be set. Settings Preset pressure is equal to half of present PIP. PEEP half of present PEEP (if > 8cm H2 O) I: E is 1:2

32 PCV VCV Vt. Variableset PIP SET & lesser variable & more Plateau pressure Set Variable Inspiratory flow decelerating type fixed flow type sinusoidal/square Inspiratory time setset Respiratory rate SetSet Barotrauma Less More Leak compensation +for minor leaknil Patients acceptance good -

33 Pressure – Support Ventilation (Psv) Patients spontaneous activity is assisted by delivery of a preset amount of inspiratory positive pressure. Patient triggers  set pressure is maintained throughout inspiration. Pressure initiated. Pressure limiting. Flow Cycling As flow reaches 25% of peak inspiratory flow /5 litres / min

34 Pressure – Support Ventilation (Psv) Low PSV – to overcome the patients WOB associated with ETT and circuits. PSV max – to achieve Vt of 10 -12 ml / Kg - may require upto 40 -50 cm H2O Can be used alone as full ventilatory support or with SIMV. Can be used as non invasive ventilatory support up to 20cm H2O2 for – transient Ventilatory support ( Narcotic overdose, asthma, acute exacerbation of COPD).

35 Mandatory Minute Ventilation (MMV): Preset MV is selected. The Ventilator calculates the patients spontaneous MV. It patients spontaneous MV < set MV, ventilator assists to achieve set MV Ventilatory assisstance may be - Volume controlled SIMV breaths Î RR /Vt - Î PSV

36 Mandatory Minute Ventilation (MMV): ADVANTAGES: MV guaranteed Useful as weaning mode DISADVANTAGES: RR may cause dead space ventilation even with acceptable MV. Respiratory muscle fatigue may develop (so high RR alarm should be activated.

37 Mandatory Minute Ventilation (MMV): INDICATIONS: During weaning period To aspiratory flow and WOB To overcome ETT/circuit resistance

38 BILEVEL POSITIVE AIRWAY PRESSURE VENTILATION(BIPAP ) A pressure controlled ventilation Allows unrestricted spontaneous breathing at any point of ventilatory cycle Time cycled changes of pressure application. Independent positive airway pressure to inspiration & expiration Inspiratory set pressure is called IAP/T high& Expiratory set pressure is called EAP/T low Usual IAP is 8 cm H 2 O & EAP is 3 cm H 2 O Trigger:flow, Limit:pressure; Cycle:time

39 BILEVEL POSITIVE AIRWAY PRESSURE VENTILATION(BIPAP) IAP causes better ventilation Paco2 EAP causes better oxygenation Pao2 Types --CPAP+PS --Two alternating CPAP level --APRV

40 BILEVEL POSITIVE AIRWAY PRESSURE VENTILATION(BIPAP) ADVANTAGES: Non invasive ventilation Useful in—end stage COPD ---restricted chest wall diseases ---neuromuscular diseases ---nocturnal hypo ventilation A weaning mode.

41 AIRWAY PRESSURE RELEASE VENTILATION(APRV)  A CPAP circuit with release valve at expiratory limb –driven by time device  APRV is a CPAP system causing. alveolar ventilation by briefly interrupting CPAP.

42 APRV…….,  Release valve opens for 1-2sec. Pr drops to lower level-low CPAP(0to-2cmH2O) Lung volume less than FRC in expiration alveolar ventilation & CO2 elimination  Reapplication of CPAP by closing valve- Higher CPAP(10to 12 cm H2O) FRC & oxygenation.

43 APRV……., ADVANTAGES: Lesser PIP,so less hemo dynamic changes. To alveolar ventilation in ALI of mild to moderate. A weaning mode.

44 INVERSE RATIO VENTILATION(IRV) I:E >1 PC-IRV / VC-IRV Ti with set pr opening of stiff alveoli units improved oxygenation Te not allowing alveoli to collapse development of intrinsic PEEP reduction of shunting

45 IRV……, Improve oxygenation by Reducing intra pulmonary shunting Improvement of V/Q matching Decreased dead space ventilation Increased MAP & intrinsic PEEP Useful when high FiO2 & high PEEP to be avoided

46 NEWER MODES 1.Dual modes: VAPS, Paug, - VS, PRVC, Autoflow, VPC 2.Switching modes: Automode 3.Proportional modes: PAV,PPS. 4.Adaptive modes: ASV

47 DUAL MODES Combination of 2modes of ventilation(PCV&VCV) to deliver guaranteed Vt/MV Volume guaranteed pr targeted ventilation Mode changes occur with in a breath-VAPS,Paug over several breaths-VS,PRVC,Auto flow,VPC

48 DUAL MODES - CHANGES WITH IN BREATH VAPS:volume assured pr support-T bird,bird8400st Paug :pr augmented ventilation-bear 1000 Vt guaranteed variable pr limited modes During inspiration,the ventilator monitors Vt if desired Vt delivered before flow drops---PSV if desired Vt not delivered before flow drops— flow continued at set pr support level till adequate Vt delivered.

49 DUAL MODES - CHANGES WITH IN BREATH Trigger – patient patient Limit -- pressure variable pr Cycle -- flow volume PSV Paug VAPS

50 DUAL MODES - CHANGES OVER SEVERAL BREATHS PRVC:Pr regulated VC-siemen300 VS:volume support:servo 300 Auto flow;DragerE4 VS-volume assured PSV PRVC-volume assured PCV Vt measured over several breaths&adequate MV achieved by changing PS/PC mode for remaining breaths.

51 DUAL MODES - CHANGES OVER SEVERAL BREATHS AUTOFLOW: Autoflow alters the function of inspiratory and expiratory valves Allowing patient to receive inspiratory flow demand Auto flow provides better ventilatory tolerance A weaning mode

52 Switching modes Ventilator can switch modes according to monitored information Automode:servo300 Switching between control /support mode depending on patient’s respiratory pattern Monitoring of patient’s respiration over fixed time period – if 2consecutive effort + PSV. -- if no efforts - PCV

53 Proportional modes PAV:proportional assist ventilation-PB840 PPS: proportional PS-Evita-E4 Proportional modes are assisting spontaneous ventilation PPV:a support mode in which pr, flow,volume are set proportional to patient’s inspiratory efforts

54 Proportional modes The more effort pt exerts-the more support the machine provides PAV allows patients to comfortably reach whatever the ventilatory pattern that suit their need.

55 Adaptive modes ASV-Adaptive support ventilation Uses pr targeted breaths to assure a target MV with decreased WOB ASV adapts to the changing capabilities of patient’s lung conditions. More efforts the patient does less - support the machine provides.

56 Adaptive modes ASV calculate the over all MV combination of volume guaranteed PSV(VS) & volume guaranteed PCV(PAVC) ASV can ventilate the patient from acute stage to a weaning stage.

57 Weaning W earing off primary pathology E limination of effects of sedation & relaxants A bsence of sepsis N o metabolic / electrolyte abnormality I nvolvement of patient N utritionally stable G ood & stable CVS


Download ppt "Basics & principles of mechanical ventilation g.k.kumar."