Download presentation
Presentation is loading. Please wait.
Published byJennifer Wood Modified over 9 years ago
1
Mock Logbook This mock logbook was produced at the request of internal verifiers at City of Westminster College. SCST felt it might be useful to publish it on the website. It has been produced by Chris Burke with grateful thanks to Gretta Borthwick and Jo Nemes for their invaluable input.
2
Record of Clinical Practice How to put your RCP together I am grateful to Jo Nemes and Gretta Borthwick who contributed to this document
3
Record of Clinical Practice The RCP is presented to SCST in 2 parts: Part I is presented toward the end of year 2 of the programme Part II is presented toward the end of year 4 of the programme
4
Internal Verification This process provides the monitoring of quality of work-based assessment IVs visit a minimum of twice a year Any documentary evidence of these visits MUST be included in the logbook
5
Part I should contain: Resting ECG Spygmomanometry
6
Part II ETT Ambulatory ECG Ambulatory BP Cardiac Catheterisation Pacing Echo
7
RCP is in 2 sections Assessment logbook Evidence Portfolio
8
Assessment Logbook
9
This section contains the documentation of the work-based assessments
10
Part I
11
Life Support A copy of a current life support certificate This should be a minimum of intermediate life support If only basic life support is available an assessment of defibrillation technique must be included
12
CPR Certificate
13
OR
14
Assessment Plan
15
Performance Criteria
16
Q&A
17
Assessor Feedback
18
ECG Includes Prep equipment, prep patient and evaluate results
19
Prep equipment (ECG)
20
Assessment Plan
21
Performance Criteria
22
ECG
23
Q&A
24
Assessor Feedback
25
Prep patient (ECG)
26
Assessment Plan
27
Performance Criteria
28
ECG
29
Q&A
30
Assessor Feedback
31
Evaluate Results (ECG)
32
Assessment Plan
33
Performance Criteria
34
ECG
35
Q&A
36
Assessor Feedback
37
ECG 3 ECG assessments are carried out in the workplace. For EACH, the following documentation must be provided:
38
Assessment Plan
39
Performance Criteria
40
ECG (with report generated by student)
41
Q&A
42
Assessor Feedback
44
Sphygmomanometry 4 assessments of blood pressure measurements are completed. At least ONE must be manual For each assessment the following documentation must be provided:
45
Assessment Plan
46
Performance Criteria (measured value must be given)
47
Q&A
48
Assessor Feedback
49
Part II
50
Exercise Testing 4 assessments of ETT are completed For each assessment the following documentation must be provided:
51
Assessment Plan
52
Performance Criteria
53
Copy of final report including ECG medians
54
Q&A
55
Assessor Feedback
56
Ambulatory ECG (AECG) 4 assessments of AECG are completed. These are a mixture of continuous and events recorders which reflect the work of the department For each assessment the following documentation must be provided:
57
Assessment Plan
58
Performance Criteria
59
Copy of the report to include ECGs
60
Q&A
61
Assessor Feedback
62
Ambulatory BP (ABP) 4 assessments of ABP are completed. For each assessment the following documentation must be provided
63
Assessment Plan
64
Performance Criteria
65
Copy of printout with your report
66
Q&A
67
Assessor Feedback
68
Cardiac Catheterisation
69
Includes Prep equipment, prep patient and evaluate results
70
Prep equipment (Cath)
71
Assessment Plan
72
Performance Criteria
73
Q&A
74
Assessor Feedback
75
Prep patient (Cath)
76
Assessment Plan
77
Performance Criteria
78
Q&A
79
Assessor Feedback
80
Evaluate Results (Cath)
81
Assessment Plan
82
Performance Criteria
83
Copy of pressures recorded and measurements made
84
Q&A
85
Assessor Feedback
86
Cardiac Catheterisation 4 assessments of cardiac catheterisation are completed (where possible including a right and left study) For each assessment the following documentation must be provided:
87
Assessment Plan
88
Performance Criteria
89
Copy of pressures recorded and measurements made including manual corrections
90
Q&A
91
Assessor Feedback
92
Pacing Implant 4 assessments of pacing implant are completed. For each assessment the following documentation must be provided
93
Assessment Plan
94
Performance Criteria
95
Copy of implant sheet with ECGs (State type of device)
96
Q&A
97
Assessor Feedback
98
Pacemaker Follow-Up 4 assessments of pacemaker follow-Up are completed For each assessment the following documentation must be provided:
99
Assessment Plan
100
Performance Criteria
101
Copy of Follow-Up sheet, ECGs and programmed data (State type of device)
102
Q&A
103
Assessor Feedback
104
Echo 4 assessments of echo are completed. For each assessment the following documentation must be provided
105
Assessment Plan
106
Performance Criteria
107
Copy of echo report to include images preferably hard copy
108
Q&A
109
Assessor Feedback
110
Evidence Portfolio Evidence must be presented for EVERY investigation Patient ID must be removed from ALL evidence (all pages not just front sheet)
111
Resting ECG x150 Put ECG report on the left If possible make report sheet landscape so scrutineer can read report whilst looking at ECG Put ECG on the right
112
Ambulatory ECG x 30 Copy of a final report with ECG examples generated by you
113
Ambulatory BP Copy of printout and your report
114
ETT Copy of final report with ECG medians
115
Cardiac Catheterisation Copy of pressures and haemodynamics with measurements which have been checked by WBA
116
Pacemaker Implant Copy of implant sheet plus relevant tracings
117
Pacemaker Follow-Up Copy of follow-up sheet plus relevant programming details and ECGs
118
Echo Final echo report with example images (Preferably hard copy)
Similar presentations
© 2025 SlidePlayer.com. Inc.