20 x 30 x 6 meter The way of working (step by step) * Draw into the hall layout all units. * Make the System block diagram. * Make the System Calculation with the DCN_NG Calculation tool. * Make the equipment list Design a congress system with DCN for:"> 20 x 30 x 6 meter The way of working (step by step) * Draw into the hall layout all units. * Make the System block diagram. * Make the System Calculation with the DCN_NG Calculation tool. * Make the equipment list Design a congress system with DCN for:">
Download presentation
Presentation is loading. Please wait.
Published byRafe Morris Modified over 9 years ago
2
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 1 DCNW Exercise 16.May.06 DCN Stand Alone System Exercise 1 Hands On !
3
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 2 DCNW Exercise 16.May.06 1.0Microphone Management,Voting and Simultaneous Interpretation with single CCU. 1.1 Single PC Control 1.2 All seat positions around the table with Wireless Table Top Units -Microphone, Loudspeaker & Voting Buttons 1.3 All seat positions around the table with Infra Red receivers 1.4Simultaneous interpretation system with 6 languages -minimal two interpretation-desks in each booth 1.5Central recording of the floor and all translation languages must be possible. 1.6All the central equipment such as Central Control Unit (CCU), Extension Power Supply (EPS) and Audio Expander (AEX) has to be placed in the 19"rack of the technical control room. 1.7 Room Dimensions (L x W x H ) in meters - > 20 x 30 x 6 meter The way of working (step by step) * Draw into the hall layout all units. * Make the System block diagram. * Make the System Calculation with the DCN_NG Calculation tool. * Make the equipment list Design a congress system with DCN for:
4
1 2 3 4 5 6 Int. Booths Int. Booths Technical Room 1 9 10 13 14 22 23 24 25 Chairman 4m 5m 30m
5
1 2 3 4 5 6 Int. Booths Int. Booths Technical Room 1 9 10 13 14 22 23 24 25 Chairman System Calculation
6
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 5 DCNW Exercise 16.May.06 Delegate positions DCN-WDV-D LBB4540/08 LBB3443/00
7
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 6 DCNW Exercise 16.May.06 DCN-WDV-D Wireless Discussion Unit with Voting Dark Delegate positions DCN-MIC S/L Pluggable microphone S= short stem L= long stem Delegate positions: Back Remark : Batteries are not included and should therefore be ordered seperately. LBB 3015/04 High-Quality Dynamic Headphones LBB 3441/10 Under-The-Chin Stereo Headphones LBB 3442/00 Single Earphone Headphones: LBB 3443/00 Lightweight Stereo Headphones LBB4540/08 Digital 8 Channel Pocket Receiver
8
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 7 DCNW Exercise 16.May.06 Chairman position with Wireless Discussion Unit with Voting DCN-WDV-D DCN-DISBCM LBB4540/08 LBB3443/00
9
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 8 DCNW Exercise 16.May.06 DCN-WDV-D Wireless Discussion Unit with Voting Dark Chairman position DCN-MIC S/L Pluggable microphone S= short stem L= long stem Chairman position: Back 10 Sets Of Buttons For Chairman Use Discussion Unit DCN-DISBCM LBB4540/08 Digital 8 Channel Pocket Receiver Remark : Batteries are not included and should therefore be ordered seperately. LBB 3015/04 High-Quality Dynamic Headphones LBB 3441/10 Under-The-Chin Stereo Headphones LBB 3442/00 Single Earphone Headphones: LBB 3443/00 Lightweight Stereo Headphones
10
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 9 DCNW Exercise 16.May.06 Interpreters Booth’s Simple loop-through interconnection Tap-Off Unit (Trunksplitter Protected) for extra system protection * Tap-off outlets with a limitation of 4,5 Watt. * *
11
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 10 DCNW Exercise 16.May.06 2x LBB 9095/30 Interpreter Headphones 2x LBB3015/04 High-Quality Dynamic Headphones 2x LBB 3443/00 Lightweight Stereo Headphones 2x DCN-IDESK Interpreter desk for 32 channels Interpreter booth’s Back 2x DCN-MICS/L Pluggable microphone S= short stem L= long stem Headphones: Interpreter booth: 1x LBB 4515/00 Tap-Off Unit ( Trunksplitter Protected ) For extra system protection:
12
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 11 DCNW Exercise 16.May.06 DCN Stand Alone System Exercise 1 End of Exercise 1 SA Menu
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.