1 Switch Mode Power Supplies Use of Transformers for Electrical (DC) Isolation Safety – Isolate output voltages from Electrical Grid Multiple Reference ( “ground”) Potentials Voltage Matching – Large difference between voltage levels of power source and converter outputs. Feedback must traverse isolation boundary 1.Separate winding for feedback 2.Optical isolation Gate Drive V dd

2 Transformer Converter Types: Flyback Converter – Derived from Buck-Boost Forward Converter - Derived from Buck Full Bridge – Derived from Buck

3 Flyback Converter  (t) i p (t) i s (t)  i p (t) + V in - + V out - i L (t) Buck-Boost Converter  (t) i s (t) (Assume CMM) (Assume CCM)

4 Flyback Converter (cont) Same as Buck-Boost

5 Flyback Converter (cont) Same as Buck-Boost

6 + V in - + V out -

7 + V out,1 > 0 - + V out,2 < 0 - Feedback Multiple Secondaries