Download presentation
Presentation is loading. Please wait.
Published byAbner Gilbert Modified over 9 years ago
1
Welding over aluminium: a potential issue? X-rays show no inacceptable defect on both samples. Further developments in collaboration with EN-MME (Welding, Material and NDT): Monitoring of the temperature during welding on several locations Metallographic section and EDS analysis (Energy Dispersive X Rays Spectrometer) to determine the presence of Aluminium, Manganese or other gaseous deposition on the weld or shell surfaces Tensile tests to confirm no mechanical degradation. Leak tests on the root pass Welding trials using existing procedure qualification records have be performed using a stainless steel backing strip and a longitudinal groove for gaseous protection machined in the aluminium support.
2
Radiographic Testing Report over the first sample (EDMS 1460432)
3
DMOS EST-MF_02-10 (EDMS 523561) To be revised in order to achieve an azimuthal pre-stress between 50 and 100MPa
4
Next step Temperature profile over length and time during welding using data loggers. 30 thermocouples distributed inside the groove, near the contact edge between aluminium and stainless steel and 10mm away. Measurement period: 5 sec Parameters variation within the allowed tolerances: Maximum beveller angle31° Minimum root face width0.7mm Maximum gap0.7mm
5
Stainless steel plates Technical Specification N° 1004 - Ed. 6 (EDMS No: 790767)