15 March 2001Absorber Review Meeting at NIU1 DAQ for Pressure Test, and later... Michael J. Haney University of Illinois m-haney@uiuc.edu
2
15 March 2001Absorber Review Meeting at NIU2 In Hand at UofI 1 GHz PC, 512M RAM, 20G disk Labview, NI-DAQ 3 National Instruments PCI-MIO-16E-1 –1.25 MS/s, 12 bit ADC –16 SE / 8 Diff analog input channels –100mV - 10V (FS) programmable gain range – 11V max CM; 25V OVP (on)
3
15 March 2001Absorber Review Meeting at NIU3 Enroute to UofI National Instruments PCI-GPIB –and cables for 3 peripherals GPIB software Labview.VI’s (work in progress) –multichannel logger –file reader
4
15 March 2001Absorber Review Meeting at NIU4 Enroute (elsewhere) Keithley 220 current source Keithley 7001 switch Keithley 2001 multimeter –all are GPIB peripherals ?
5
15 March 2001Absorber Review Meeting at NIU5 DAQ Plan for Pressure Test every millisecond –read (up to) 24 stain gauges –via PCI-MIO-16E-1 boards –common-mode permitting... every second –read strain gauges, pressure, flow –all (40) channels –via Multimeter/GPIB
6
15 March 2001Absorber Review Meeting at NIU6 DAQ Plan for Pressure Test (continued) Spool everything to a file –10 GB / (24 * 12 bits * 1 KHz) = 77 hours –“start” and “stop” are moot... Analyze later –find quasi-static measurements between fills –look for vibrations –examine rupture
Similar presentations