1 Responsibilities & Planning DCS WS 13.06.05 L.Jirdén.

Similar presentations


Presentation on theme: "1 Responsibilities & Planning DCS WS 13.06.05 L.Jirdén."— Presentation transcript:

1 1 Responsibilities & Planning DCS WS 13.06.05 L.Jirdén

2 2 Responsibilities u ACC (and its CERN partners) will provide u DCS H/W Infrastructure u Back-End System u Common Services u Interface to TRG, DAQ, HLT, LHC via ECS u S/W Infrastructure for Detector Applications u Detectors will provide u Detector Sub-System Devices and Cabling u Detector Specific Networking (Ethernet switches) u Detector Applications for each Sub-System u Detector Specific Services u Integration of all Detector Sub-Systems to a full Detector Control System u Interface to the Alice Detector Control System layer

3 3 ACC will provide: DCS H/W infrastructure u DCS Racks in CR3 u 1 for Back-end PC’s u 1 for ELMB power u 6 for Front-end (detector) PC’s u Network u DCS network ports in all racks with DCS computers & devices u detectors to specify requirements: “rack content meetings” u Computers u Back-end: prototype installation exists u Front-end: detectors to specify requirements: ACC will propose u PCI interfaces: detectors to specify requirements: ACC will propose u Peripherals u Printers, displays, etc

4 4 Firewall Terminal Server IP Reach for KVM Domain Controller DB Server (Config.) DB Server (Archive) File Server Network and Security FSM Alarms General DCS Electricity & Racks Gas & Cooling Environment General services LHC & Access Alignment Information Server CERN System Management DCS Operator DCS Status Safety Status ConsolesRemote AccessBackend Servers Worker Nodes Detector Front-end PC’s ACR Consoles DB Server (Archive) Infrastructure, network Racks, network, cabling KVM switches controlled power plugs Hot swap spare servers Disks & memories Spares DCS network DCS H/W infrastructure

5 5 [FED] Chambers ISEG PCI-CAN ISEG OPCserver PVSS II Chambers Wiener PCI-CAN Wiener OPCserver Ethernet User interface Database(s) RCU OPC client DIM client 1082881..31..22? PVSS II Chambers, detector ELMB 1..18~400? PVSS II RS232 HVrod Heinzinger 1118?3221216 High Voltage Low VoltageFEETemp. MonitorVery High Voltage PVSS II OPC client PVSS II OPC client PCI-CAN ELMB OPCserver PVSS II OPC client TPC (1) CC HVLV EC HV S [FSM?] Control room (ACR) 108? 26/11/04 Eth. Switch ?? E E LV monitor DIMsrv DIMcl DDL PVSS II DIMclient HVrod ELMB ?1?2 VHV Curr. Monitor PCI-CAN ELMB OPCserver PVSS II OPC client C Front-End OPC client ACC WILL PROVIDE: SOFTWARE INFRASTRUCTURE FOR F-END’s WXP/Linux PCI OPCserver PVSS II FW LIBRARIES Detectors to specify requirements: ACC will propose

6 6 [FED] Chambers ISEG PCI-CAN ISEG OPCserver PVSS II Chambers Wiener PCI-CAN Wiener OPCserver Ethernet User interface Database(s) RCU OPC client DIM client 1082881..31..22? PVSS II Chambers, detector ELMB 1..18~400? PVSS II RS232 HVrod Heinzinger 1118?3221216 High Voltage Low VoltageFEETemp. MonitorVery High Voltage PVSS II OPC client PVSS II OPC client PCI-CAN ELMB OPCserver PVSS II OPC client TPC (1) CC HVLV EC HV S [FSM?] Control room (ACR) 108? 26/11/04 Eth. Switch ?? E E LV monitor DIMsrv DIMcl DDL PVSS II DIMclient HVrod ELMB ?1?2 VHV Curr. Monitor PCI-CAN ELMB OPCserver PVSS II OPC client C DETECTORS will provide * SUB-SYSTEM DEVICES; HVPS, LVPS, etc * ELMB’s and ELMB + CAN power by ACC * CABLES; CAN and Interlock cables by ACC * SPECIFIC NETWORKING; switch to RCU, etc. * DETECTOR SPECIFIC SERVICES (GAS, COOLING)

7 7 PVSS CONNECTION: OPC, DIM, DIP FW CORE FRAMEWORK DEVICE COMPONENTS APPLICATIONS ALARM CONFIGURAT ACCESS ARCHIVAL TRENDING TOOLS JCOP ARCHIVAL PVSS CONFIG ALICE STANDARDS: - ALICE DCS State Diagrams (HV, LV, FEE, Detector DCS, ALICE DCS) - Guidelines & Conventions for ALICE PVSSII Control Software - ALICE DCS Computing Rules FEE CONFIG CONDITION ACC DETECTOR APPLICATIONS DETECTORS PVSS applications

8 8 ACC will provide * integration of services * interface to ECS sub-sys 1 device a Control Units Device Units To physical devices det B sub-sys 2 device b … … gas DCS ECS power det Edet D … … … racks sub-sys 1sub-sys 2 device e … Detectors will provide * Integration of subsystems * Interface to DCS

9 9 Installation schedule HMPID TOF / TRD PHOS TPC/ITS Vacuum FMD/V0/T0 RB26 Muon spectrometer FMD/V0/T0 RB24 PMD Stage2 Vacuum L3 doors Shielding Final Installation PHASE 1 PHASE 2 PHASE 3 PHASE 4 April 2007Jan 06Aug 06Mar 2007 TPC HMPID INFRASTRUCTURE Pre-Installation Nov 05

10 10 TPC pre-installation example July Nov June Feb Jan Aug TPC CHAMBER MOUNTTPC FEETPC COMMISSIONING DecMar Apr Sep Oct July 20052006 May June GCS B-END DSS NETWORK RACKS TPC DCS INTEGRATION GOOFIE PULSER LASER ALICE DCS INTEGRATION ECS – DAQ INTEGRATION PC and PLC H/W RODC VHV FEE TMON LV HV

11 11 CR4 SX2SGSXL2 CR3 F-end comp TPC TPC GAS SYSTEM DSS HMPID B-end comp F-end comp DSS NETWORK MAY 05 Plans for 2005 OCT 05 F-END OCT 05 F-END JUL 05 DSS JUL 05 B-END JUL 05 DSS SEP 05 TPC GAS u TPC and HMPID Pre-installation at P2

12 12 PURCH REQ GUIDE TEST Final Installation Muon spectrometer FMD/V0/T0 RB24 PMD Stage2 Vacuum L3 doors Shield B-END F-END: HMPID TOF TRD PHOS MTG MTK F-END: TPC ITS FMD/V0/T0 PMD PHASE 1 PHASE 2 PHASE 3 PHASE 4 April 2007Jan 06Aug 06Mar 2007Jan 05 HMPID TOF / TRD PHOS TPC/ITS Vacuum FMD/V0/T0 RB26 INSTALLATION AND VALIDATION DETECTOR APPLICATIONS SOFTWARE Detector groups: Central Team: TOF TRD