End Station Personal Safety Shutter TSC Design Presentation.

Similar presentations


Presentation on theme: "End Station Personal Safety Shutter TSC Design Presentation."— Presentation transcript:

1 End Station Personal Safety Shutter TSC Design Presentation

2 ES PSS Assembly Safety Requirements: Established OP 02-30

3 History - LBL Engineering note #10450 Different Versions: Proto Original Current - Rev. A (6mm.) - Rev. 1 (22mm.) - Rev. E (0.125”)

4 ES PSS Assembly Design Primary design details: Critical dimensions remain same Design is retro-fitable New switches New switch actuation design New switch access design Meets OP 02-30 procedure criteria

5 New Switch Specification Switch Details: “924CE1-S3” Safety Rated High Cycle life Reputable Manufacturer Available

6 ISO Views

7 Upper and Lower Switch Actuation

8 Back Side Access and Top View

9 General Design Changes Changes to address Tracking issues: 1) Documentation via an engineering notes #10450 - MDC Specific #10457 - General PSS Assys at ALS 2) New part number assigned, Old versions obsolete 3) Shutters need tag for exterior indication - Name (LBL ALS ES PSS Assy) - Part number (200863-2002) - Serial number (unique for ever unit) 4) Print details - Fabrication/ Assembly Procedure - Bill of material / wire diagram - Reference LBL Engineering note #10450

10 Specific Mechanical Improvements Changes to address fabrication and reliability issues: 1)Bellows leaks -> Usage 30K cycles vs. 100K cycles design - MDC design changes to increase number of cycles 2)Limit Switch failures -> New switches and actuation design 3)Access to switches -> New door style access 4)Paddle thickness -> Specified as 0.125” minimum - Changes design requires new assembly 5)Assembly inconsistencies -> MDC Procedure requirement added 6)Operational issues -> MDC Testing required. - Electrical circuit verification. - Cycle test – at least 100 cycles. - Paddle thickness measured. - Documentation to be provided.

11 Misc. views of assembly

12 Front Access View

13 Old Switch Design Old design / issues: Switch not safety rated Low cycle life Improper actuation No adjustability Wire damage

14 ES PSS Assembly Checklist To be completed after fabrication and delivered with each PSS assembly.