Presentation is loading. Please wait.

Presentation is loading. Please wait.

Submarine Cable System

Similar presentations


Presentation on theme: "Submarine Cable System"— Presentation transcript:

1 Submarine Cable System
- Focusing on the Link between China & Korea - Noriyuki Takeda and Junji Matsuda KDDI Submarine Cable Systems Inc. (KDDI-SCS) May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

2 Submarine Cable Systems between Korea and China
Beijing Seoul CKC Taean 0.56Gbit/s x 1WDM x 2FP Qingdao Pusan APCN2 10Gbit/s x 64WDM x 4FP Chongming C2C 10Gbit/s x 96WDM x 8FP As you may know, many submarine cable systems have already instolled all over the world, of course including the link between Korea and China. These days, most submarine cable systems are used for data transmission than voice communication. And some of you are interested in thesubmarine cable system itself. So today, I would like to talk about key technologies to realize the cable system between K&C. KJCN 10Gbit/s x 24WDM x 12FP May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

3 Use Pursuant to Company Instructions
Outline 1. Introduction 2. Configuration of Submarine Cable System 3. Transmission Technologies - Experimental Results 4. How to realize the cable system between Korea and China ? - Network configuration - Cost 5. Conclusion May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

4 Use Pursuant to Company Instructions
Outline 1. Introduction 2. Configuration of Submarine Cable System 3. Transmission Technologies - Experimental Results 4. How to realize the cable system between Korea and China ? - Network configuration - Cost 5. Conclusion May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

5 Repeaterless system and Repeater system
SLTE SLTE Cable MC MC Repeaterless System SLTE : Submarine Line Terminating Equipment MC : Maintenance Controller LME : Line Monitoring Equipment PFE : Power Feeding Equipment SLTE SLTE Repeater There are two kinds of submarine cable system. One is Repeaterless system, the other is Repeater system. As you can see in this figure, the configuration of Repeaterless system is very simple. Repeaterless system consists of SLTE and MC. On the other hand LME PFE Cable PFE LME MC MC Repeater System May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

6 Use Pursuant to Company Instructions
What is “WDM” ? Wavelength Division Multiplexing Total capacity 10Gbit/s x n WDM Wavelength Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Optical Fiber Multiplexer Demultiplexer May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

7 Advantage of WDM : Upgrade
- Small initial investment - Increase the system capacity when you need without changing the wet plant - After upgrade - Initial Cable capacity : 10Gbit/s x N Trans-mitter Recei-ver Repeater Trans-mitter Recei-ver Trans-mitter Recei-ver May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

8 Use Pursuant to Company Instructions
What is Maximum Number of Wavelength? 10Gbit/s per wavelength Maximum Number of Wavelength Repeater System KJCN Repeaterless System System Length [km] May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

9 Use Pursuant to Company Instructions
Why is the Number of l Limited in Repeaterless System? Repeater Trans-mitter Recei-ver Optical Fiber Trans-mitter Recei-ver Trans-mitter Recei-ver Loss (0.2dB/km) Power Transmitter Receiver Threshold of receiver distance May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

10 Use Pursuant to Company Instructions
Upgrade Strategy - Repeater system - Repeaterless system Cable l Increasing the # FP (Use the dark fibers) Increasing the # wavelength > 3T bit/s / cable May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

11 Use Pursuant to Company Instructions
Outline 1. Introduction 2. Configuration of Submarine Cable System 3. Transmission Technologies - Experimental Results 4. How to realize the cable system between Korea and China ? - Network configuration - Cost 5. Conclusion May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

12 Key Technologies for Repeaterless System
Number of wavelengths : ~16 (Capacity : ~160Gbit/s /fiber) 1~2 (Capacity : 10~20Gbit/s /fiber) - Optical Booster and Preamplifier Optical Booster Optical Pre-amplifier - Raman Amplifier - Remote EDFA Amplifier Remote Pump Source FEC - FEC (Forward Error Correction) Trans-mitter Recei-ver May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

13 Use Pursuant to Company Instructions
Repeaterless System - 10Gbit/s x 100WDM, 200km - Trans-mitter Recei-ver Optical Fiber Multiplexer Demultiplexer 100WDM 200km BER : 10-9 Spectrum after 200km transmission Transmission characteristics May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

14 Use Pursuant to Company Instructions
Key Technologies for Repeater System Repeater Fiber (~100km) FEC Recei-ver Trans-mitter How to transmit a large number of wavelength…….. 1. By making the signal bandwidth wider 2. By making the wavelength spacing narrower May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

15 Use Pursuant to Company Instructions
Repeater System - 10Gbit/s x 200WDM, 9200km - 200WDM 9,200km Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Trans-mitter Recei-ver Repeater Fiber (~45km) BER BER : with super FEC Output of Transmitter After 9,200km Transmission May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

16 Use Pursuant to Company Instructions
Outline 1. Introduction 2. Configuration of Submarine Cable System 3. Transmission Technologies - Experimental Results 4. How to realize the cable system between Korea and China ? - Network configuration - Cost 5. Conclusion May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

17 Key Factors to Realize the System
- Demand - Feasibility of transmission technologies - Location of cable landing station - Network configuration - Cost May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

18 Comparison of New and Existing Cable Landing Station
Using the Existing Stations is preferable ! May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

19 Network Configuration
Plan the optical cable system between Korea and China using the Existing cable landing stations. Taean (泰安) - Qingdao (青島) Distance : ~ 560km Taean : Exist. Qingdao : Exist. 560km 3 options of Network configuration May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

20 Network Configuration
Repeater System Option 1 Repeaterless System Option 2 New Station Taean : Exist. Repeaterless System + Backhaul System Option 3 Qingdao : Exist. May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

21 Use Pursuant to Company Instructions
Conditions for Cost Estimation Initial After Upgrade Note: 5 Repeaters are assumed in Repeater system (Option 1). May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

22 Cost for Initial Investment
Price(M$) Initial May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

23 Use Pursuant to Company Instructions
Cost for Upgrade Price(M$) After Upgrade (Ultimate) Initial May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

24 Terminal Equipment Bay
Repeaterless System EDF for remote amplification LTU with FEC for undersea cable system WTU Up-stream Remote EDF Pump Source Down-stream 1FP LTU : Line Terminating Unit WTU : Wavelength Terminating Unit Repeater System LTU (compatible with terrestrial LTU) WTU Down-stream 1FP Up-stream Repeater May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

25 The Number of Terminal Bay
Repeater System LTU Bay Cable Qingdao Taean Repeaterless System Twice ! Quigdao Taean New Station May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

26 Use Pursuant to Company Instructions
Conclusion - Configuration for Repeater system and Repeaterless system were presented. - The three options of system between Korea and China were shown. - From the standpoint of the cable capacity and cost, Repeater system is more attractive for the system between Korea and China. May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions

27 Use Pursuant to Company Instructions
Please visit out web site! KDDI-SCS Home page : http// N.Takeda (Technical) : J.Matsuda (Commercial) : Thank you! May 25, 2002 KDDI-SCS Proprietary Use Pursuant to Company Instructions


Download ppt "Submarine Cable System"

Similar presentations


Ads by Google