(C) 2006, SUCCESS by DESIGN Surge Values at Each Test Stator surged to fault Indicates decrease in dielectric strength following each test. Applied Surge Voltage Applied Surge Test
2
(C) 2006, SUCCESS by DESIGN MCA of Stator During Experiment 1-21-32-3 Impedance414020 Inductance888 Phase Angle83 I/F-49-50-49 1-21-32-3 Impedance21 39 Inductance887 Phase Angle7776 I/F-47-45-47 Test without Rotor Test with Rotor Before Start Note: The large impedance difference Is a doubling of applied test frequency That appears when a defect is present.
3
(C) 2006, SUCCESS by DESIGN Comparison 1-21-32-3 Impedance21 40 Inductance887 Phase Angle77 I/F-47-45-47 1-21-32-3 Impedance21 39 Inductance887 Phase Angle77 76 I/F-47-43-47 Test after Surge #6 Test following last Surge