Presentation is loading. Please wait.

Presentation is loading. Please wait.

Derek A. Skolnik Robert L. Nigbor and John W. Wallace Specifications For Building Instrumentation.

Similar presentations


Presentation on theme: "Derek A. Skolnik Robert L. Nigbor and John W. Wallace Specifications For Building Instrumentation."— Presentation transcript:

1 Derek A. Skolnik Robert L. Nigbor and John W. Wallace Specifications For Building Instrumentation

2 2 OBJECTIVE Determine minimum requirements for specifications of sample rate, resolution, and time synchronization STRATEGY Quantify the sensitivities of ground motion intensity measures and engineering response quantities to DAQ APPROACH 1. Understand how engineers use strong-motion data 2. Simulate the noisy DAQ process 3. Perform sensitivity analyses

3 3  Introduction  DAS Specifications  DAQ Simulation  Sensitivity Studies  Conclusions OUTLINE

4 (Goel & Chopra 1997) Engineering use of Strong-Motion Response Data  Traditional – validate modeling assumptions and develop code provisions: fundamental period approximation formulas  Modern – tall building issues, structural health monitoring (SHM) INTRODUCTION 4

5 5  Alternative designs citing Chap 16 of ASCE 7  NDA of 3D FEM w/ suite of motions & peer review  Exposed fundamental issues: ground motion selection, modeling guidelines, acceptance criteria  LA-TBSDC publish document for LA-DBS (2008) INTRODUCTION StoriesChannels 10 – 2015 20 – 3021 30 – 5024 > 5030  Since 1965 LA requires accelerographs at base, mid-level, and roof One Rincon Hill - MKA Tall Building Construction  UCLA, LA-DBS & CSMIP update requirements  Deployment approval by peer review panel

6 6 INTRODUCTION Arabdrill 19, UAE Structural Health Monitoring (SHM)  Assess health of instrumented structures from measurements  Detect damage before reaching critical state and allow for rapid post-event assessment –Potentially replacing expensive visual inspection which is impractical for wide spread damage in urban areas Steel Joint Damage 1994 Northridge I-35W Bridge 2007

7 7 INTRODUCTION Strong Motion Instrumentation Programs (SMIP)  CSMIP (CGS), ANSS & NSMP (USGS), K-net/KiK-net (Japan), Taiwan Seismology Center (CWB)  Provide real-time ShakeMaps and data for engineers and scientists to improve hazard mitigation  Since early 20 th century with focus on ground monitoring  Uniform structural instrumentation specifications are lacking 650 ground 170 buildings 92 ground 51 buildings 762 ground 133 buildings

8 Intensity Measures (IM)  PGA – Peak Ground Acceleration  PGV – Peak Ground Velocity  PSA – Peak Response Spectral Pseudo-Acceleration  MMI – Modified Mercalli Intensity INTRODUCTION Engineering Demand Parameters (EDP)  PFA – Peak Floor Acceleration  PID – Peak Interstory Drift Advanced Engineering Analyses  SID – System Identification, Model Updating  SHM – Structural Health Monitoring  PGA – Peak Ground Acceleration  PGV – Peak Ground Velocity  PSA – Peak Response Spectral Pseudo-Acceleration  PFA – Peak Floor Acceleration  PID – Peak Interstory Drift 8

9 9  Introduction  DAS Specifications  DAQ Simulation  Sensitivity Studies  Conclusions OUTLINE

10 10 Recommended Specification ANSS (USGS 2005) CSMIP (CGS 2007) Sensor Range ADC Resolution Sample Rate ±4g 16bits 200sps ± 4g 18bits 200sps Sample Sync Reference Time Clock Stability 1%  t 1.0ms 0.1ppm 0.2ms 0.5ms 1min/month DAS SPECIFICATIONS R (bits/g) S (sps) T se (ms) SMIP Specifications  Recommended specifications for civil structures (buildings)  Based on qualitative assessment and experience Guideline for ANSS Seismic Monitoring of Engineered Civil Systems, USGS Report 2005-1039 Integrated Tri-Axial Accelerograph, CGS/DGS SYSREQ 2007-TR

11 11 Data Acquisition Systems (DAS)  Sampling – sample rate ( sps = 1 /  t )  Quantization – resolution ( LSB = Range / 2 Bits )  Time stamp for synchronization of multiple channels Sampling Quantization.......110001001010 Reference Time Sensor DAS SPECIFICATIONS

12 12 Data Acquisition Errors  Sampling – initial sampling instant and clock jitter  Quantization – Differential Non-Linearity (DNL) Jitter DNL analog discrete digital Sampling Instant DAS SPECIFICATIONS

13 13  Introduction  DAS Specifications  DAQ Simulation  Sensitivity Studies  Conclusions OUTLINE

14 14 Baseline Earthquake Record Set  30 EQ records downloaded from PEER, NCESMD, K-Net, KiK-Net, COSMOS  Selected to capture broad nature of earthquakes  Digitally enhanced to increase resolution: resample to 2kHz, zero-pads for filtering, band-pass filter 0.1-50Hz DAQ SIMULATION

15 15 DAQ Simulation Baseline Signal SR ADC Sinusoids Earthquake ground motions Structural responses Jitter and initial sampling instant Digital Signal Analysis Sensitivity Analysis IM: PGA, PGV, PSA EDP: PFA, PID SNR and Peak value DAQ SIMULATION

16 Sinusoidal Signal Sampled Signal Clock Jitter  Independent of sample rate  Can be neglected Jittery Sampled Signal 16 DAQ SIMULATION 100sps

17 Initial Sampling Instant  Depends on sample rate  Biased error – always negative analog sampled EpEp analog sampled EpEp 20Hz 40Hz 17 DAQ SIMULATION E p (%) Error in peak value ( E p ) 100sps 10Hz

18  S = [50-500] sps   t=1/ S  R = [6-24] bits/g  res=g /2 R 200sps 12b/g 1.t 0 ~ U (0,  t) 2.t i = t 0 + i ·  t 3.x i = interp(X @ t i ) 4.x i =round(x i / res)·res X = EQ record 40dB50dB3020 18 DAQ SIMULATION SNR

19 19  Introduction  DAS Specifications  DAQ Simulation  Sensitivity Analysis  Conclusions OUTLINE

20 Intensity Measures  PGA – 100sps, 6bits/g for error less than 5%  PGV – 50sps, 8bits/g for error less than 5%  PSA – 200sps, 8bits/g for error less than 5% 14 bits/g 16 R = 6 200sps 500sps 100sps 12 10 8 100sps 500sps 200sps 50sps SENSITIVITY ANALYSIS 20

21 21 Baseline Building Response Set  Simulate responses to baseline EQ record set by superimposed first few modal responses  Assumptions: bounded by flexural & shear idealizations, uniform mass and stiffness,  n = 5% H  RC SW  Steel EBF  Dual System  Steel MRF . RC MRF  Flexural Bldg Shear Bldg SENSITIVITY ANALYSIS

22 22 (Goel and Chopra 1997-98, Naeim 1998) Fundamental Period  Depends on building structure and height... sort of  Based on real data from instrumented buildings  Empirical conventions in code (ASCE 7) are lower bounds ASCE 7-05 S12.8.2.1 Steel MRF SENSITIVITY ANALYSIS

23 23 SimulationDigitizingProcessing Structure Type: Flexural/Shear SR N ADC AA AgAg N: No of Stories S: Sample Rate R: Resolution A g : Ground Acceleration AA : Absolute Acceleration RA : Relative Acceleration RD : Relative Displacement LEGEND High-pass Filter Double Integrate FcFc SNR RD RA = AA – A g RD SENSITIVITY ANALYSIS Newmark Integration

24 Displacement (in) No correction SNR = -31dB Detrend SNR = -16.3dB F c = 0.01Hz SNR = -8.9dB F c = 0.1Hz SNR = 20.5dB F c = 1.0Hz SNR = 1.25dB SENSITIVITY ANALYSIS 24

25 Optimizing Frequency Cutoff  High-pass 4 th order acausal digital Butterworth filter  A single floor of a 10-story bldg to one earthquake  Resolution is important which corroborates Boore’s (2003) findings of ADC quantization being a source of numerical drifts 100sps 200sps 500sps 8b/g 12b/g 14b/g 18b/g 100sps 200sps 500sps 8b/g 12b/g 14b/g 18b/g Shear: f n = [1.5, 9.3, 26] Hz Flexural: f n = [0.4, 1.2, 1.9] Hz SENSITIVITY ANALYSIS 25

26 26 Engineering Demand Parameters  PFA – 100sps, 8b/g for error less than 5%  PID – 100sps, 14b/g for error less than 5% 8 201816141210 bits/g Flexural Shear SENSITIVITY ANALYSIS 200sps 500sps 100sps

27 27 Time Synchronization Error  Sync errors are additional to digitizing error  PID – 200sps, 16b/g and sync to 1.0ms for total error < 5% 10ms 1.0ms 0.1ms SENSITIVITY ANALYSIS 10ms 1.0ms 0.1ms

28 28  Introduction  DAS Specifications  DAQ Simulation  Sensitivity Analysis  Conclusions OUTLINE

29 29 Specification ANSS (USGS 2005) CSMIP (CGS 2007) Recommend (Skolnik 2009) Range ADC Resolution Sample Rate ±4g 16bits 200Hz ±4g 18bits 200Hz ±4g 20bits 200Hz Sample Sync Reference Time 0.05ms 1.0ms 0.2ms 0.5ms 1.0ms Potential Improvements  Other specifications – frequency response, dynamic range, cross-axis sensitivity, sensor layout  Improved simulations – non-uniform stiffness; vary damping ratios, combo flex-shear shapes, non-linear responses  Other engineering analyses – system identification CONCLUSIONS

30 30 Support provided by NSF CENS and nees@UCLA Future Publications BSSA: A quantitative basis for strong-motion instrumentation (12/09) EQS: A quantitative basis for building instrumentation


Download ppt "Derek A. Skolnik Robert L. Nigbor and John W. Wallace Specifications For Building Instrumentation."

Similar presentations


Ads by Google