Download presentation
Presentation is loading. Please wait.
Published byJennifer Matthews Modified over 9 years ago
1
Andrei Kounine / MIT on behalf of AMS-02 collaboration ICHEP 2004, Beijing Astroparticle physics with AMS-02
2
Goals: Astroparticle Physics: - Search for Cosmic Antimatter - Searches for Dark Matter Cosmic Ray Astrophysics … AMS-02 Experiment A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 Collect ~10 10 Cosmic Particles (p, D, He, C, …,e, ) from ~ GV to few TV.
3
AMS-02 Experiment AMS-02 Experiment Anticoincidence: veto plastic scintillators used in Trigger Time of Flight: 2x2 planes of scintillator hodoscope Resolution T=90-150 ps. Used in Trigger Velocity measurement L/ct1-ct2 / 0.03 dE/dx measurements Tracker : 8 layers of Si strip planes (6 m 2 ). 27.5 / 52 pitch Resolution: = 10 (bending) and 30 (non bending) Rigidity measurements up to ~3TeV dE/dx ~ Z 2 measurement. Conversion of gamma e+e- Magnet: B dipol =0.86 Tesla I~460A NbTi/copper conductor Size: d=1.2m l=0.8 m; Mass 2.3 t E=5.2MJ stored cooled to 1.8K by superfluid He A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
4
AMS-02 Experiment Ring Image Cherenkov Detector: radiators (NaF n=1.336 and Aerogel n=1.035) +PMT's measurement up to 20 GeV/n, / 0.01-0.04% Charge measurements N γ ~Z 2 ( =0.2) up to Z=26 Electromagnetic Calorimeter: 18 planes of Pb+ scintillator fibers Thickness ~16 X o and ~ 0.5 nucl.. Energy resolution: dE/E=0.023+0.10/ E[GeV] Used in gamma trigger e, / h separation ~10 3 E=1-1000 GeV Transition Radiation Detector: 20 layers of 6mm straw tubes filled with Xe/Co2 interleaved with fleece radiator (22 mm). dE/dx measurements. Separation e/h ~10 3 - 10 2 p=1-300 GeV A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
5
AMS-02 Detector Performance A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 Data MC Data ECAL resolution: Energy resolution Angular resolution ΔE/E=0.023+0.10/ E(GeV)
6
AMS-02 Detector Performance A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 MC Data Tracker resolution: Spatial resolutionRigidity resolution
7
Angular Resolution Energy Resolution A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 AMS-02 Detector Performance
8
The Primordial Antimatter content of the Universe is unknown. ~100 MeV flux excludes wide antimatter regions up to 20-100 Mpc Sakharov’s 3 Principles of Baryogenesis : 1. Baryon Number Violation (not confirmed….) 2. C and CP Violation (strong….) 3. Deviation from Thermal Equilibrium … but alternative models predict distant Antimatter local domains ! Single anti-He Cosmic Rays nucleus Strong Evidence for Large Anti-matter Domains in the Universe Search for Antimatter A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
9
Search for Antimatter Model-independent AMS-01 limit A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 AMS-02 will probe antimatter domains to the edge of Universe
10
“Standard Cosmology” Dark Energy – 73 % of critical density Matter – 27 % of critical density Matter breakdown: – 0.5 % Stars – 4.4 % Barions – 22 % CDM We do not know what CDM is: – Super Symmetry: LSP – Low Scale Gravity: KK particles – SuperWIMP: Graviton, Gravitino – … A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
11
SUSY Dark Matter SYSY postulates spin partners for all known particles MSSM best CDM candidate – neutralino : 0 1 – LSP 0 1 0 1 e + e - – suppressed by spin 0 1 0 1 WW, ZZ, – vanishing coupling for Bino Plausible signature – low energy anti-protons and anti-deuterons: 0 1 0 1 bb, W + W -, ZZ, Z , H + H -,... p –,anti-D, e +, , +X High energy electrons and photons is also a possibility. A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
12
Low Scale Quantum Gravity (Extra Dimensions) generically predict Kaluza-Klein bosons with mass n/R. BB e + e - - dominant channel (~20%) A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 Kaluza-Klein Dark Matter Cheng, Feng, Matchev (2002)
13
Graviton/Gravitino Dark Matter A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 Heavy WIMPs exist in early universe only. They decay slowly to non-interacting sWIMPs Signature: photons from decays: WIMP sWIMP Decay time is sensitive to m = m WIMP – m sWIMP Feng, Rajaraman, Takayama (2003) gravitino graviton m sWIMP = 0.1, 0.3, 1 TeV (from below)
14
Dark Matter Searches AMS-02 is a general purpose particle detector: – p - : Excess at Low Energy and spectrum distortion at High Energy – D - : Excess at Low Energy – e + : Structure in Spectra above few GeV – : Energy Spectra differ from “power laws” A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
15
7 models Dark Matter Searches: Antiprotons Background Primary antiprotons from SUSY χ annihilation SUSY χ annihilation A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
16
Dark Matter Searches: Antiprotons After 3 years of running Background rejection: p/p- > 10 6 and e-/p- 10 3 -10 4 A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
17
Dark Matter Searches: Anti-deuteron More promising than antiprotons A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
18
Dark Matter Searches: Positrons e + AMS02-spectrum after 3 years of data taking: p/e+ and e-/e+ background rejection: 10 4 -10 6 Excellent energy resolution.Excellent energy resolution. ~30% stat error at 300 GeV, ~1% stat error at 50 GeV.~30% stat error at 300 GeV, ~1% stat error at 50 GeV. A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
19
Precise data extended to higher energies will be provided by AMS m 130.3 GeV Dark Matter Searches: Positrons m 336 GeV Based on the work of E.A. Balts et al. 99 A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
20
Dark Matter Searches: Photons A.Kounine Dark Matter searches with AMS-02 ICHEP 2004 Diffusion flux Extra-galactic flux MC
21
mSUGRA results: Integrated flux from GC as a function of m in the Focus Point scenario (large m 0 values), for two NFW halo profile parameterizations. R 0 = 8.0 kpc, r 0 = 0.3 GeV/cm 3, a = 20 kpcR 0 = 8.5 kpc, r 0 = 0.4 GeV/cm 3, a = 4 kpc Dark Matter Searches: Photons A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
22
AMS prospects Launch ready – September 2007 as of now AMS launch is foreseen for end of 2007 - beginning 2008 AMS-02 will collect data for 3-5 years on ISS: – Antimatter search with a sensitivity 10 -9 – Dark Matter content in various channels (p-, D-, e+, ) – High statistics cosmic ray measurements – -Astrophysics – Exotics, … A.Kounine Dark Matter searches with AMS-02 ICHEP 2004
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.