Download presentation
Presentation is loading. Please wait.
Published byDorcas Curtis Modified over 9 years ago
1
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear -ray spectroscopy experiment Missing mass analysis : Magnetic spectrometer (identification of hypernuclear bound states ) Beam K - Scattered - -ray measurement by Ge detector array rays from hypernuclei : Particle- coincidence ( +, K + ) @ KEK, (K -, - ) @ BNL Magnetic spectrometers + Hyperball Upgrade Hyperball-J Missing mass analysis -ray measurement (K -, - ) reaction @ J-PARC Optimized magnetic spectrometer + Hyperball-J SksMinusHyperball-J To analyze 1.4 GeV/c (1.1~1.8 GeV/c) scattered - Large acceptance ~100 msr, 20 degree → Efficient tagging of hypernuclei and angular selectivity Good momentum resolution 2 4 MeV/c (FWHM) Good momentum resolution 2 4 MeV/c (FWHM) → Identification of bound states of hypernuclei (mass resolution ~5 MeV (FWHM) ) (mass resolution ~5 MeV (FWHM) ) Modified SKS (Superconducting Kaon Spectrometer) (K -, - ) reaction @ p K = 1.5 GeV/c SDC1~4 : Momentum analysis STOF : Time-of-flight SAC : - identification SFV : K - beam veto Beam decay background Veto SMF : - from K - → - + SMF : - from K - → - + SP0 : - from K - → - + 0 _ Target ~20 g/cm 2 1 m 2.2T Previous condition SksMinus Beam K - decay products make serious background ⇒ Same kinematical region to (K -, - ) reaction K - → - - + (5.58%) K - →e - 0 (4.87%) K - → - 0 (3.27%) K - → - 0 0 (1.73%) Contribution of three-body decay is relatively small. Simulated performance Acceptance, Momentum resolution and Particle ID Acceptance at 1.4 GeV/c, ~130 msr ~130 msr Enough angular acceptance, ~20 degree ~20 degree Momentum resolution at 1.4 GeV/c ~2.1 MeV/c (FWHM) ~2.1 MeV/c (FWHM) Rejection of K - beam through background SAC ~98% + SFV Reaction ID by BAC and SAC (n=1.03) @ trigger STOF : Time resolution ~150 ps (rms) Large drift chambers Optimized incident beam angle Beam decay background veto counters K - → - (63.4%) Muon Filter _ - (passing through) - (absorbed in the iron) Sufficient performance to reduce the trigger rate and background K - → - 0 (21.1%) PiZero Veto _ _ Wall configuration and simulated efficiency Mechanical cooling by Pulse tube PWO background suppression Waveform readout for pulse shape analysis ~6% photo peak efficiency @ 1 MeV (half picture) Mechanical cooler ⇒ Suppression of the neutron damage effect with Ge crystal below 85 K (LN2 cooling ~90 K) ~2 keV (FWHM) energy resolution and cooling power of less than 85 K are achieved. Ge Cooler Pulse Tube refrigerator PWO CsI PMT Doped PWO crystal Cooling of PWO below 0 ℃ W-type U-type L-type -type The performance of background suppression of the PWO counter by cooling below 0 ℃ is the same as of BGO counter. But, small light yields (PWO/BGO = 1 /10) The PWO crystal has very first decay constant ~6 ns. (~300 ns for BGO) To improve energy resolution and recover rejected events at high counting rates Baseline shift restoration Pileup signals separation Pulse height ADC ⇒ FADC (wave form digitization) (after shaping) In the test experiment, the positron beam is irradiated to Ge detector to make frequent baseline shits by reset signal. ⇒ The restoration of the baseline shits 3.7 keV ⇒ 3.1 keV (FWHM) 2.6 keV w/o beam No baseline restoration Baseline restoration New Ge detector Cooling power Ge crystal temperature less than 85K when biased Low mechanical vibration Minimization of microphonics noise Compact size Realization of the planar arrangement of Ge detectors Hyperball-J ∞-type element PWO counter and Waveform readout for high counting rates Summary J-PARC E13 experiment by the (K -, - ) reaction @ p K =1.5 GeV/c Optimal magnetic spectrometerOptimal magnetic spectrometer New Hyperball system for the high counting rateNew Hyperball system for the high counting rate Magnetic spectrometer, SksMinus and newly constructed array, Hyperball-J SksMinus performance : More than 100 msr acceptance, 20 degree coverage, ~2 MeV/c momentum resolution Hyperball-J : ~6 % efficiency, Mechanical cooling system, PWO counter, Waveform readout The experiment will be performed at 2009. PWO counter types 60 Co 1.3 MeV -ray spectrum Several light hypernuclear -ray spectroscopy experiments are planned. ( 4 He, 7 Li, 10 B, 11 B, 19 F ) SKS for 1.05 GeV/c ( +, K + ) reaction (p K = 0.72 GeV/c) 2.7T Beam K BACSAC Target 20cm Decay Overlap 86% of events detected 14 % non-rejected (stopped in the iron) by offline analysis Totally > 99.9 % Over kill for true π ~2.5% 80% of - 0 events detected 10 sets of 3 mm lead plate and 8 mm scintillation counter layer at 1.5 GeV/c beam. SAC Beam veto (SFV) BAC Muon Filter Neutron damage High counting rate 10 cm 13 cm Ge energy spectrum 1 MeV ray J-PARC
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.