Attentuators & Outlets Attentuators & Outlets
2
Outlet Connections ESP-3642 5190 4706 2385 606 3806 5935 2748 9910 > <
3
Quik-Connect
4
Balancing Orifices Works with all plenums 15, 35, 50% Easy to re-balance system
5
Rough In Kits Supports Tubing Metal construction Designates where outlets will go before dry wall is put up
6
Sound Attenuator 3 foot standard section Pre-assembled connectors Reduces velocity noise End of every run
7
Absorber Type Attenuators: Performance is based on diameter, length and materials used. Used only for higher frequency sounds. Are ineffective at frequencies less than 500Hz. Length is determined by the wavelength to be attenuated.
8
High Velocity Air Generates High Frequency Noise. Wavelengths 8kHz = 1.69” 4kHz = 3.39” 2kHz = 6.78” 1kHz = 13.56” 500Hz = 27.12”
9
Standard Outlet Flex Seals to Ceiling
10
Cutting Nozzles Stay about 6” from wall Vertical or Horizontal work just as well 90 degree wire probe Use “Salad Bowl” cutter
11
Fits into Tight Spaces without Major Remodeling Maximizes Living Space
12
Easily Hidden Runs inside closets Inside walls Below floors Over ceilings
13
90 Degree Wall Elbow Allows for installation in tight 2x4 wall cavities Pre-insulated Has Kwik Connect lugs AC-KCWE
14
Decorative Outlets
15
More Outlet Choices