E-165 (FLASH) Experiment Status Report Johnny S.T. Ng SLAC EPAC Meeting, Nov. 15, 2003
2
Fluorescence from Air in Showers (FLASH) J. Belz 1, Z. Cao 2, F.Y. Chang 4, P. Chen 3*, C.C. Chen 4, C.W. Chen 4, C. Field 3, P. Huentemeyer 2, W-Y. P. Hwang 4, R. Iverson 3, C.C.H. Jui 2, G.-L. Lin 4, E.C. Loh 2, K. Martens 2, J.N. Matthews 2, J.S.T. Ng 3, A. Odian 3, K. Reil 3, J.D. Smith 2, P. Sokolsky 2*, R.W. Springer 2, S.B. Thomas 2, G.B. Thomson 5, D. Walz 3 1 University of Montana, Missoula, Montana 2 University of Utah, Salt Lake City, Utah 3 Stanford Linear Accelerator Center, Stanford University, CA 4 Center for Cosmology and Particle Astrophysics (CosPA), Taiwan 5 Rutgers University, Piscataway, New Jersey * Collaboration Spokespersons SLAC E-165 Experiment
3
Outline Introduction: Motivation and Goals Report on the Sep.2003 Run –Thin-target results –Spectrograph results Plans and outlook –Thick-target stage
4
Motivation Recent observations of ultra-high energy cosmic ray events extend out to 10 20 eV However, there is apparent discrepancy between AGASA and HiRes > ~10 19 eV
5
Cosmic Rays have been observed with energies beyond 10 20 eV The flux (events per unit area per unit time) follows roughly a power law: ~E -3 Changes of power-law index at “knee” and “ankle”. Onset of different origins/compositions? Where does the spectrum stop? Ultra High Energy Cosmic Rays
6
AGASA HiRes Discrepancy Between Two UHECR Experiments
7
Motivation (cont.) Recent observations of ultra-high energy cosmic ray events extend out to 10 20 eV However, there is apparent discrepancy between AGASA and HiRes > ~10 19 eV Systematics in energy measurement being investigated by both experiments. One possible contribution to the discrepancy is the air fluorescence yield.
8
Current Understanding of the Air Fluorescence Spectrum Bunner (1967), Kakimoto et al. (1995), Nagano et al. ( 2002) indicates ~15% systematic errors in overall yield and larger errors in individual spectral lines. Ground based experiments – non-linear effects possible due to λ -4 dependence of atmospheric attenuation. At 30 km, event energy can change by 25% if 390 nm line intensity changes by 40%.
9
Experimental Program The T-461 Test (June 2002) showed that we can measure the pressure dependence and fluorescence lifetime integrated over 300-400 nm with FFTB beams Spectrally resolved pressure and lifetime measurements Energy dependence over realistic shower energies The E-165 program: Thin target Thick target T-461
10
Objectives Of E-165 Spectrally resolved measurement of fluorescence yield to better than 10%. Study effects of atmospheric impurities. Observe showering of electron pulses in air equivalent substance (Al 2 O 3 ) with energy equivalents around 10 18 eV. Investigate dependence on electron energy.
11
Sep. 2003 Run: Thin Target FFTB Beam: 28.5 GeV, 5E8 – 2E9 e/pulse Main target vessel: –Dry air, N2, “SLAC Air”, 10-760 Torr –Narrow-band filters (10nm BW, 300-420 nm) –Calibrated HiRes PMTs Spectrograph system –Dry air, N2, “SLAC Air”, 15-760 Torr –Hamamatsu linear-array MPMT’s –Grating spectrograph system: 6 nm and 4 nm per pixel
12
Thin-Target Run: Main Vessel Layout e Pressure vessel NB Filter wheel Calibration LED housing e Filter wheel PMT Pressure vessel
13
OTR Beam Spot Monitor e Monitor beam spot size and position Provide energy profile diagnostics as well Wonderful contribution from the CosPA (Taiwan) group 45-deg OTR foil
14
E-165: Air Fluorescence Spectrum Narrow Band filters Dry-Air 750 Torr Arbitrary normalization N1A: Corrected for filter transmission and quantum efficiency Preliminary Bunner
15
Air Fluorescence vs. Pressure E-165 Preliminary
16
Effects of Contaminants “SLAC Air”: H 2 O, and traces of CO 2 and Ar Possible slight difference, but within our present measurement accuracy. E-165 Preliminary
17
Beam-related Background Various measurements as cross-checks: “Black”-filter, “Blind”-PMT, and Ethylene (non-fluorescent) gas.
18
Narrow-Band Data Analysis Data have been corrected for Filter transmission efficiency PMT Quantum efficiency Background contribution Further systematic issues (some examples): Absolute calibration: PMT + Mirror + Filter Absolute calibration of low-current toroid Stability (gain variation over time, etc.) Uncertainty in background subtraction Detector acceptance (ray-tracing + modeling)
19
Grating Spectrograph e Light pipe and mirror Grating Spectrograph
20
Spectrograph Measurement: Air E-165 Preliminary!
21
Spectrograph: Fluorescence vs. Pressure E-165 Preliminary At low pressure (<100 Torr): Fluorescence mechanisms extremely complex! Sensitive to non-linear effects. Above ~150 Torr (for HiRes,eg): Small pressure variation Allows altitude spectral correction
22
Spectrograph Data Analysis Data have been corrected for: PMT quantum efficiency vs wavelength Anode - anode difference in response Wavelength dependence of transmission to PMT Spectral dispersion at the PMT face (measured using a mercury lamp with 4 useful lines.) Further systematic issues (some examples): Independently measure transmission and associated uncertainties. Calibrate dispersion for the wider-range grating set-up Quantify the non-linear effects seen at higher beam intensities and low pressures.
23
Summary on Thin-Target Run Over-all successful thin-target run Measured spectrally resolved fluorescence for various pressures and gas mixtures Took reference data at low beam charge (1E7 e/pulse) for the thick-target stage Beam-related background (most likely soft photons from shower) was a major problem Detailed data analysis underway – plan to present results at the upcoming “International Workshop on Air Fluorescence – Air Light 03” in December 2003.
24
The Next Step: Thick-Target For a 10 18 eV cosmic-ray proton, or a 30 GeV electron, the cascade consists of electrons with energies between 100 keV and a few GeV at shower-max. Pass electron beam through varying amounts of approx. air equivalent showering material (Al 2 O 3 ). Measure light yield as a function of depth in the shower –Is fluorescence proportional to dE/dx? –What are the contributions of low-energy (<1 MeV) electrons? –Can existing shower models (EGS, GEANT, CORSIKA) correctly predict fluorescence light?
25
Thick Target Requirements Low beam intensity ~ 10 7 e/pulse –Beam monitor and control Showering beam spreads out at target exit – Careful calculation/measurement of optical acceptance necessary. Need shower profile measurements to constraint Monte Carlo simulations Beam-related background issue –Beam test scheduled for Jan. 5-7, 2004 to optimize layout and shielding
26
Thick Target Setup Design to be finalized pending beam test and further simulation studies.
27
Summary E-165 is an experiment with the aim to contribute and support astrophysics investigations using high energy beams. We’re making good progress thanks to the strong support from SLAC.