1
Particle Detectors for Colliders Calorimeters Robert S. Orr University of Toronto
2
R.S. Orr 2009 TRIUMF Summer Institute Layers of Detector Systems around Collision Point Generic Detector
3
Scintillators charged particle photons Charged particle passing through matter distorts atom molecule lattice Relaxation of distortion – light emitted Emitted photon may – excite another molecule Successive excitation & emission – different λ photons each step whole chain Very fast – good timing resolution
4
R.S. Orr 2009 TRIUMF Summer Institute Can be extremely efficient ~ 100 photoelectrons per cm. Spatial resolution ~ size of scintillator ~10s cm Scintillating fibres
5
R.S. Orr 2009 TRIUMF Summer Institute Why are scintillators transparent to emitted light? Stokes shift
6
R.S. Orr 2009 TRIUMF Summer Institute Wavelength Shifting
7
R.S. Orr 2009 TRIUMF Summer Institute number of stages Fast Low noise High gain Photomultiplier
8
R.S. Orr 2009 TRIUMF Summer Institute PM Sensitivity
9
R.S. Orr 2009 TRIUMF Summer Institute Modern Photodetectors Micro-channel plates Multi-anode pm Hybrid pm Visible light photon counters
10
R.S. Orr 2009 TRIUMF Summer Institute Electromagnetic Showers incident Converts to 2 electrons Each electrons will have emitted a brems photon of energy Now have 4 particles energy Number of particles after Average energy At the critical energy assume this is max depth shower grows as ln E linear energy measurement resolution improves with energy
11
R.S. Orr 2009 TRIUMF Summer Institute Monte Carlo Simulation of an EM Shower Calc Put b=0.5 Get a from
12
R.S. Orr 2009 TRIUMF Summer Institute “b” is sort of material independent
13
R.S. Orr 2009 TRIUMF Summer Institute Transverse Shower Profile Shower Broadens as it develops Pair Brems Compton Multiple Coulomb Moliére Radius Like radiation length, Moliére radius scales for different materials In terms of Moliére radius, shower width is roughly independent of material - 90% of energy in Shower Broadens as it develops dense central core spreading with depth
14
R.S. Orr 2009 TRIUMF Summer Institute Comparison of Hadronic & Electromagnetic Showers
15
R.S. Orr 2009 TRIUMF Summer Institute Hadronic Calorimeters Strong (nuclear) interaction cascade Similar to EM shower hadronic interaction length Shower length hadronic calorimeter nearly always sampling calorimeters Energy Resolution leakage of energy shower fluctuations invisible energy loss mechanisms
16
R.S. Orr 2009 TRIUMF Summer Institute Sampling Calorimeter
17
R.S. Orr 2009 TRIUMF Summer Institute Hadronic Lateral Shower Profile Fe Hadronic shower much broader than EM Mean hadronic versus MCS Fe
18
R.S. Orr 2009 TRIUMF Summer Institute Hadronic Shower Longitudinal Development ZEUS Uranium/Scint
19
R.S. Orr 2009 TRIUMF Summer Institute Lateral Scaling with Material 90% containment does not scale core scales
20
R.S. Orr 2009 TRIUMF Summer Institute Calorimeter Energy Resolution sampling and shower fluctuations number of samples energy energy deposited in a sampling step stochastic term
21
R.S. Orr 2009 TRIUMF Summer Institute Calorimeter Energy Resolution counting statics in sensor system this term is usually negligible e.g. # of photo-electrons in PM, ion pairs in liquid argon mean # of photo-electrons in PM per unit of incident energy shower leakage fluctuations – make calorimeter as deep as $$ allow
22
R.S. Orr 2009 TRIUMF Summer Institute Calorimeter Energy Resolution noise - detector or electronics increases with number of channels summed over -important for low level signal -liquid argon electronics -detector capacitance N channels with some intrinsic noise noise (energy) deposited energy behaviour
23
R.S. Orr 2009 TRIUMF Summer Institute Calorimeter Energy Resolution inter - calibration uncertainty of channels constant -constant in E spatial in-homogeneity of detector energy response fractional channel to channel gain uncertainty dead space temperature variation radiation damage all these influence spatial variation of effective energy response
24
R.S. Orr 2009 TRIUMF Summer Institute Calorimeter non-uniformity
25
R.S. Orr 2009 TRIUMF Summer Institute Layers of Detector Systems around Collision Point Generic Detector
26
R.S. Orr 2009 TRIUMF Summer Institute Semi-empirical model of hadron shower development radiation length hadronic part electromagnetic part interaction length - significant amount of material in front of calorimeter (magnet coil etc.)
27
R.S. Orr 2009 TRIUMF Summer Institute More Rules of Thumb for the Hobbyist Shower maximum 95% Longitudinal containment 95% Lateral containment Mixtures in sampling calorimeters active + passive material
28
R.S. Orr 2009 TRIUMF Summer Institute Typical Calorimeter Resolutions Homogeneous EM (crystal, glass) CLEO, Crystal Ball, Belle, CMS..... Sampling EM (Pb/Scint, Pb/LAr) CDF, ZEUS, ALEPH, ATLAS..... Non-compensating HAD (Fe/Scint, Fe/LAr) CDF,ATLAS,H1, LEP = everyone Compensating HAD (DU/Scint) ZEUS, HELIOS
29
R.S. Orr 2009 TRIUMF Summer Institute Invisible Energy in Hadronic Showers
30
R.S. Orr 2009 TRIUMF Summer Institute Difference in Response to Electrons and Hadrons
31
R.S. Orr 2009 TRIUMF Summer Institute Effect of e/h on Energy Resolution Fe/Scint DU/Scint Resolution tail
32
R.S. Orr 2009 TRIUMF Summer Institute Effect of e/h on Linearity DU/Scint Fe/Scint
33
R.S. Orr 2009 TRIUMF Summer Institute
34
Weighting to Correct for e/h Energy resolution does not improve Weight down EM part of shower tune
35
R.S. Orr 2009 TRIUMF Summer Institute Jet Energy Resolution Fluctuations between EM and Hadronic component in jets will degrade the energy resolution for jets Jet-jet Mass Resolution Effects other than e/h dominate the 2- jet mass resoluton
36
R.S. Orr 2009 TRIUMF Summer Institute Jet-Jet Mass Resolutions
37
R.S. Orr 2009 TRIUMF Summer Institute Conceptual Readout Schemes
38
R.S. Orr 2009 TRIUMF Summer Institute ZEUS Forward Calorimeter
39
R.S. Orr 2009 TRIUMF Summer Institute
40
Layers of Detector Systems around Collision Point Generic Detector
41
LAr Calorimetry SM Higgs Discovery Potential Five different detector technologies Calorimetry coverage to EM Calorimeter WW Fusion Tag jets in Forward Cal EM Calorimeter Hadronic & Forward Calorimeters
42
Design Goals Technology EM Calorimeters ( ) and Presampler ( ) Hadronic Endcap ( ) Forward Calorimeter ( ) LAr Calorimeter Technology Overview Lead/Copper-Kapton/Liquid Argon Accordion Structure Copper/Copper-Kapton/Liquid Argon Plate Structure Tungsten/Copper/Liquid Argon Paraxial Rod Structure
43
LAr and Tile Calorimeters Tile barrelTile extended barrel LAr forward calorimeter (FCAL) LAr hadronic end-cap (HEC) LAr EM end-cap (EMEC) LAr EM barrel
44
R.S. Orr 2009 TRIUMF Summer Institute Electromagnetic Barrel Barrel Module Schematic with presampler 64 gaps /module 2.1 mm gap 2x3100 mm long Half Barrel Assembly 2x16 modules I.R/O.R 1470/2000 mm 22 - 33 3 longitudinal samples presampler
45
R.S. Orr 2009 TRIUMF Summer Institute Electromagnetic Endcap 96 gaps /module outer wheel 32 gaps/module inner wheel 2.8 - 0.9 mm gap outer 3.1-1.8 mm inner 2x8 modules Diam. 4000 mm 22 - 37 3 longitudinal samples Front sampling of 6 for, - strips.
46
R.S. Orr 2009 TRIUMF Summer Institute Accordion Structure Pb Absorber Honeycomb spacer & Cu/Kapton electrode
47
R.S. Orr 2009 TRIUMF Summer Institute Prototype of EM endcap Detail of Kaptons
48
R.S. Orr 2009 TRIUMF Summer Institute ATLAS FCAL
49
Pictures of assembly process
50
LAr Forward Calorimeters FCAL C assembly into tube – Fall 2003
51
R.S. Orr 2009 TRIUMF Summer Institute ATLAS HEC Structure
52
Hadronic Endcap Calorimeter (HEC) Composed of 2 wheels per end Front wheel: 67 t 25 mm Cu plates Back wheel: 90 t 50 mm Cu plates Rear Wheel Wheel Assembly Front Wheel
53
Oct 2002
55
Electromagnetic Endcap
56
Hadronic Endcap
57
HEC – FCAL Assembly
58
Lar Endcap Installed in ATLAS