RADIOLOGIC IMAGING EQUIPMENT 1
2
THE X-RAY ROOM 2
3
PROCESSING ROOM 3
4
THE X-RAY ROOM 4
5
X-RAY TUBE CONTROL PANEL ANCILLARY EQUIPMENT 5
6
6
7
THE X-RAY TUBE Electromagnetic Energy Spectrum 7
8
THE X-RAY TUBE Electromagnetic Radiation Bits of energy that passes thru matter Travels at the speed of light Not always ionizing!!!! photon 8
9
THE X-RAY TUBE REVIEW OF X-RAY DISCOVERY CROOKE’S TUBE WILHELM ROENTGEN’S OBSERVATIONS November 8, 1895 BERTHA ROENTGEN’S HAND 9
10
THE X-RAY TUBE What do you need to produce ionizing radiation? 10
11
THE X-RAY TUBE A source of electronsA force to move them quickly Something to stop them very suddenly 11
12
THE X-RAY TUBE Remember the light bulb!! 12
13
THE X-RAY TUBE 13 The source of electrons
14
THE X-RAY TUBE 14 The Law of Attraction
15
THE X-RAY TUBE Simple car battery 15
16
THE X-RAY TUBE 16
17
17 Let’s make this terminal very negative Let’s make This terminal Very positive
18
18
19
THE X-RAY TUBE 19
20
THE X-RAY TUBE anodecathode Glass envelope Tube housing X-ray tube 20
21
THE X-RAY TUBE 21
22
THE X-RAY TUBE 22
23
THE X-RAY TUBE Cathode filament Focusing cup Milliamps Anode Target/focal track rotor kilovolts 23
24
THE X-RAY TUBE CATHODE ANODE VACUUM GLASS ENVELOPE CURRENT 24
25
THE X-RAY TUBE 25
26
THE X-RAY TUBE 26
27
THE X-RAY TUBE 27
28
THE X-RAY TUBE anodecathode Glass envelope Tube housing X-ray tube 28
29
THE X-RAY TUBE Glass Envelope vacuum Pyrex glass Surrounds anode and cathode Tube Housing Lead and steel Port for exit beam Surrounds glass envelope 29
30
THE X-RAY TUBE 30
31
THE X-RAY TUBE steel casing Glass envelope Port/window oil Lead casing anode cathode Which end of tube is the positive end? Which end is the negative end? Is this a stationery or rotating anode? 31
32
THE X-RAY TUBE What is electromagnetic spectrum? What are photons? What is radiation? What is ionizing radiation? What is x-ray? What are roentgen rays What are photons? 32
33
33
34
34
35
35
36
THE X-RAY TUBE The amount of electrons burned off TThe amount of time charged is applied The strength of the positive charge 36
37
THE X-RAY TUBE The amount of electrons burned off Milli-amperage Electron cloud Thermionic Emission Focusing cup ??amount of electrons??? ? How many mA are applied? 37
38
THE X-RAY TUBE The amount of time charged is applied The longer the the milli-amps are applied, the more electrons are burned off. How many seconds are applied? 38
39
THE X-RAY TUBE The strength of the positive charge The stronger the force of the positive charge, the faster the electrons rush toward anode, The more x-rays are generated. The force of the charge is measured by kilovoltage (kV) applied to the anode 39
40
THE X-RAY TUBE milli-Amperage (mA) Time-(in fractions of seconds) kilo-Voltage (kV)(kVp) technique 40
41
CONTROL PANEL Where the technologist controls the x-ray machine Where technique selection occurs Always located outside the x-ray room 41
42
CONTROL PANEL 42
43
CONTR0L PANEL kVp controls Strength of beam kVp more penetrating 50-110 kVp in diagnostic x-ray Controls contrast and density on image 43
44
CONTROL PANEL mA controls the amount of electrons Time controls how long the electrons are sent to anode Frequently used as a single unit of measure mAs Controls the density of the image 44
45
ANCILLARY EQUIPMENT Image Receptors Table Tube supports Grids Collimators Misc Equipment 45
46
IMAGE RECEPTORS Film cassettes CR cassettes Direct imaging Bucky tray(grid) Wall Bucky tray(grid) 46
47
IMAGE RECEPTORS Film Cassettes are light tight, with intensifying screens. They serve to hold the film safe from any damage. CR cassettes look almost identical but contain a PSP plate that is used to create the image. 47
48
IMAGE RECEPTORS 48
49
TABLE 49
50
TABLE 50
51
TABLE 51
52
TUBE SUPPORTS Tube Suspension systems are available in 5 versions. Be sure to check the book for configurations. 52
53
TUBE SUPPORTS Designed to help technologists with various tube locations for creative imaging. 53
54
TUBE SUPPORTS Tube Movement Longitudinal Transverse Vertical Angling or Rolling Rotating Telescoping 54
55
COLLIMATORS Limits the X-ray field Limits the transverse and longitudinal field Positive beam limitation 55
56
COLLIMATORS 56
57
COLLIMATORS Always collimate smaller than the image receptor 57
58
GRIDS Device used to “clean up” the x-ray image by reducing the amount of scatter radiation reaching the image receptor Used on larger, thicker parts Built with parallel lead strips to absorb the scatter radiation 58
59
GRIDS ??? Primary beam + - Exit Radiation 59
60
GRIDS No gridgrid 60
61
GRIDS 61
62
MISCELLANEOUS EQUIPMENT Positioning sponges Tape Lead aprons Lead blockers Markers Sand bags linens 62
63
MISCELLANEOUS EQUIPMENT 63
64
MISCELLANEOUS EQUIPMENT 64
65
X-RAY TUBE CONTROL PANEL ANCILLARY EQUIPMENT 65
66
THE X-RAY ROOM 66
67
PROCESSING ROOM 67
68
PROCESSING ROOM Film Screen Image Production Digital Image Production 68
69
PROCESSING ROOM-IMAGE PRODUCTION ??? Primary beam + - Exit Radiation 69
70
PROCESSING ROOM-IMAGE PRODUCTION RADIOGRAPH- PERMANENT RECORD OF IMAGE, BY FILM OR BY COMPUTER STORAGE 70
71
DARK ROOM 71
72
DARK ROOM 72
73
DARK ROOM Pass Box Lockable from inside, contains cassettes Clean, dry, dustless countertop Work space be free of clutter Safe light 15 watt bulb 3 feet from film, countertop Orange or amber filter/light bulb, depends on film emulsion type Cassettes, empty and full Film bin Must be light tight Sometimes locks with door Processor Needs water supply, Must be clean Chemicals Store safely 73
74
DARK ROOM 74
75
DARK ROOM 75
76
CR READER CR - Computed Radiography Computed Radiography is an indirect type of imaging system. The receptor used within a CR cassette is called a photostimulable imaging plate (PSP) and it absorbs the radiation exiting the patient. The exposed plate is processed in a CR reader, where the absorbed energy is extracted. The information stored in the CR imaging plate must be processed before viewing can occur. The resultant latent image data is converted from an analog to a digital signal and a digital image is created. Computed Radiography x-ray systems predominantly use conventional x- ray tube systems. 76
77
CR READER 77
78
REVIEW 78
79
REVIEW 79
80
REVIEW 80
81
REVIEW A source of electronsA force to move them quickly Something to stop them very suddenly 81
82
THE X-RAY TUBE 82
83
1 2 33 4 5 6 7. Describe Tube Travel 8. Describe tube travel 9. Describe how the tube would travel in order to direct x- ray output at #1?? 83