1
MassDEP1 Emission Limits Wood Fired Electric Generating Units EBC Seminar October 28, 2005 Recovering Renewable Energy from Construction and Demolition Debris Wood
2
MassDEP2 Current MassDEP requirement for Emission Limits Case-by-case determination BACT LAER Limits in regulations (PM, NOx, opacity)
3
MassDEP3 Review of Impacts Will not exceed NAAQSs Will not exceed AALs/TELs Will not cause a condition of Air Pollution (e.g. noise, odor, dust)
4
MassDEP4 AALs/TELs for C&D wood burning POLLUTANTTEL (24 hour std) (ug/cm) AAL (annual std) (ug/cm) Antimony2.01.0 Arsenic0.00050.0002 Cadmium0.0030.001 Chromium (metal)1.360.68 Chromium (VI) compounds0.0030.0001 Copper0.54 Lead0.140.07 Mercury (elemental)0.140.07 Nickel0.270.18
5
MassDEP5 AALs/TELs for C&D wood burning (Continued) POLLUTANTTEL (24 hour std) (ug/cm) AAL (annual std) (ug/cm) Selenium0.54 Vanadium0.27 HCl77 PCDD/PCDF (Teq)5.4E-08
6
MassDEP6 Notice of Inquiry Emission Limits (from permits) Name plate capacity>25 MW SO20.025 #/MMBtu NOx0.075 #/MMBtu Ammonia13 ppm @ 3%O2 CO0.1 #/MMBtu PM100.011 #/MMBtu VOC0.01 #/MMBtu ToxicsAALs/TELs Opacity10%
7
MassDEP7 Notice of Inquiry Emission Limits (achievable) Name plate capacity>25 MW SO20.02 #/MMBtu NOx0.015 #/MMBtu Ammonia2 ppm @ 3%O2 CO0.01 #/MMBtu PM100.011 #/MMBtu VOC0.01#/MMBtu Opacity5% Metals99.9% removal and AALs/TELs HCl50 ppm @ 3%O2
8
MassDEP8 Next Steps Should the standards be input or output standards. Decide on standards, averaging time, testing and monitoring.