Download presentation
Presentation is loading. Please wait.
Published byMargery Dennis Modified over 9 years ago
1
Center for the Arts Towson, Maryland Schematic Lighting Proposal Ben Mitten Architectural Engineering Pennsylvania State University
2
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Location Towson University Center for the Arts 7815 Osler Drive Towson, MD 21252 Towson University Map
3
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Project Data General Information Overall size of the project – 288, 000 square feet Total project budget - $ 42 million Occupants: Dance Program Art Program Music Program Theater Program
4
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Building Layout
5
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Large Work Space Paint Studio Special Purpose Space Dance Studio Circulation Space Main Lobby Outdoor Space North Façade Conceptual Design Spaces
6
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Building Layout Paint Studio
7
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Location 4 th floor of the north-east section of the building Space Characteristics Size- 1668 square feet Major space properties - Projection screen surface mounted - Entire north wall is glazing - Floor easels - Exposed ceiling with height of 14’ – 6”Tasks Painting- Figures, Human Models, objects Presentations/Pin-ups Sketching Paint Studio
8
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Criteria Provide light for correct color appearance and contrast Lighting for facial modeling and objects Distribution of light on easels Manual lighting system and daylight controls Illuminance of 50 fc on the horizontal and 30 fc on the vertical Flinn Mode to achieve- clear Minimize direct glare Power Density Requirements Power density of no more than 1.6 Watts per square foot Paint Studio
9
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Paint Studio
10
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Paint Studio Pictures During Construction Phase
11
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Solution Daylight integration Indirect fixtures Track Spots Automated curtain system for maximum system control by occupants Paint Studio
12
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Luminaire Type to meet Design Solution Fluorescent Indirect fixture with track lighting on the bottom for system flexibility. Paint Studio
13
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Paint Studio
14
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Building Layout Dance Studio
15
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Location 1 st floor of the north-east section of the building Space Characteristics Size- 3000 square feet Size- 3000 square feet Major space properties Major space properties - Special spring floor - Acoustical drapes - Batten system for theater/task lighting located 21’ above the floor Tasks Choreograph dance routines Small dance shows Set-up/Tear down for shows Paper tasks Dance Studio
16
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Dance Studio Pictures During Construction Phase
17
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Dance Studio
18
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Dance Studio
19
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Criteria Provide a minimum illuminance of 40 fc on the floor Provide a visibly pleasing space Allow for a flexible system in order to program different routines Flinn mode to achieve- clear Power Density Requirements Power density of no more than 1.8 Watts per square foot Dance Studio
20
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Solution Down lights for the seating area Luminaire to light up back wall Dance Studio Lighting Before and After a Show
21
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Dance Studio Theatrical Lighting Provided by the University
22
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Luminaire Types to meet Design Solution HID Luminaire to light up back wall CF Luminaire for seating area Dance Studio
23
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Building Layout Lobby
24
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Location 3 rd floor in the center of the building Space Characteristics Size- Approximately 4000 square feet Size- Approximately 4000 square feet Major space properties Major space properties - Finish stone floor in lobby - Cantilevered awning over the entrances of the concert hall and theater - Wood wall finish Main Lobby
25
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Main Lobby Pictures During Construction Phase
26
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Lobby Plan View Main Lobby Main Theater Main Concert Hall Entrance
27
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Lobby
28
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Lobby
29
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Tasks Circulation- access to the main concert hall and main theater Social Gathering Reading Special events (art exhibits) Design Criteria Most important space in the building Provide a visibly pleasing atmosphere Facial modeling is very important in the space with the interaction people in this space Flinn modes to achieve- relaxed, spacious, and public Power Density Requirements Power density of no more than 1.8 Watts per square foot Main Lobby
30
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Solution Down lights through out the main corridor Down lights in the slanted ceilings Up lights illuminating the slanted ceilings Cove light in above the main corridor and the two slanted ceilings Down lights to illuminate important doors in the space Main Lobby
31
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Cove Lighting Down Light Up Light Main Lobby Down Light Lighting During Non-Show Times Lighting During Show Times Main Lobby
32
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Luminaire Types to meet Design Solution Cove Lighting – Fluorescent Strips Down Lighting – CF Down Lights Up Light - HID Spots for light on slanted ceiling - HID In-floor Uplight - Industrial Fluorescent strips on canopies. - Industrial Fluorescent strips on canopies. Main Lobby
33
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Building Layout North Facade
34
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Location North side of the building Space Characteristics Major space properties Major space properties - Round and jagged façade - Walls consist of glazing systems, masonry and different types of siding - This side of the building faces one of the main roads on campus, Osler road Tasks Visibly pleasant A sense of soaring North Facade
35
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts North Facade Pictures During Construction Phase
36
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Criteria Provide 5 fc in the horizontal and 3 fc in the vertical of illuminance A sense of soaring Make the building a landmark of excellence Sharp horizontal lines at the round façade and vertical lines at the jagged façade Power Density Requirements Power density of no more than 0.25 Watts per square foot North Facade
37
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Design Solution North Facade
38
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Luminaire Types to meet Design Goal HID flood light to light upper area of building HID lighting for under canopy North Facade
39
Center for the Arts Schematic Lighting Proposal Ben Mitten Center for the Arts Any Questions ? Questions