Presentation is loading. Please wait.

Presentation is loading. Please wait.

Introduction to AC Motors ChE 462. AC Motors Synchronous motor – constant speed independent of load; compressors Induction motor is a common form of asynchronous.

Similar presentations


Presentation on theme: "Introduction to AC Motors ChE 462. AC Motors Synchronous motor – constant speed independent of load; compressors Induction motor is a common form of asynchronous."— Presentation transcript:

1 Introduction to AC Motors ChE 462

2 AC Motors Synchronous motor – constant speed independent of load; compressors Induction motor is a common form of asynchronous motor and is basically an ac transformer with a rotating secondary. Rotational speed a function of load

3 Induction motor Induction motor derives its name from currents flowing in the secondary member (rotor) that are induced by alternating currents flowing in the primary member (stator). The combined electromagnetic effects of the stator and rotor currents produce the force to create rotation.

4 An Industrial Induction Motor

5

6 Allen-Bradley (Rockwell) Internals of an Induction Motor

7

8 3 Phase Stator Connection of an Induction Motor

9

10

11 http://www.sea.siemens.com/step/templates/lesson.mason?motors:2:6:6#

12 Induction motor Magnetic field rotates is the synchronous speed of the motor and is determined by the number of poles in the stator and the frequency of the power supply: ns = synchronous speed f = frequency p = the number of poles

13 s = slip na = actual speed Induction motor Synchronous speed is the absolute upper limit of motor speed. If the rotor turns exactly as fast as the rotating magnetic field, then no lines of force are cut by the rotor conductors, and torque is zero. When running, the rotor always rotates slower than the magnetic field. The rotor speed is just slow enough to cause the proper amount of rotor current to flow, so that the resulting torque is sufficient to overcome windage and friction losses, and drive the load. The speed difference between the rotor and magnetic field, called slip, is normally referred to as a percentage of synchronous speed:

14

15 Induction Motor Performance Curves