Computed tomography (CT) is a diagnostic procedure that uses special x-ray equipment to obtain cross-sectional pictures of the body. Computed tomography (CT) is a diagnostic procedure that uses special x-ray equipment to obtain cross-sectional pictures of the body. Detector Gantry Rotation X-ray Tube X-ray Beam
5
Direct detector 1 Indirect detector 2 Direct detector uses a semiconductor material to convert X-ray photons into an electrical charge Indirect detector uses scintillator to transform the radiation into the visible light, and uses photo detector device for measurement
6
In this paper, the miniature computed tomography system using the indirect X-ray detector panel created from an array of USB cameras coupled with an intensifying screen is presented. In this paper, the miniature computed tomography system using the indirect X-ray detector panel created from an array of USB cameras coupled with an intensifying screen is presented. The aim of this study is carried out to construct the cross sectional images obtained from this system. The aim of this study is carried out to construct the cross sectional images obtained from this system.
7
Miniature CT system consists of 3 parts USB Web Cameras Lead Glass Intensifying Screen Type Gd 2 O 2 S:Tb Object -Image Sensor Type CMOS - Resolution 640 x 480
8
USB cameras aligned in 1x3 array Lead Glass
9
Flow chart described a procedure to achieve the final image Correct an image distortion by a camera calibration Template matching and cross correlation Fuse image by matrix transformation Apply a Lambert-Beer law to the stitched image Image spline by a weighted average technique Achieve the final image Reduce noise by a median filter Capture a projection image
10
Calibration Phantom Acrylic plate Metal ball
11
Adjust to align with the same alignment Center ray
12
Center of X-ray beam (dash line) The projection image of calibration phantom
13
The center ray point must be shifted to the center of an X-ray detector
14
Phantom created for using as the object Cement plaster Air
15
The projection angle is 2 degrees per a projection from 0 to 360 degrees. The projection angle is 2 degrees per a projection from 0 to 360 degrees. The filtered back projection was used to reconstruct cross sectional images. The filtered back projection was used to reconstruct cross sectional images. Phantom 80 kV, 100mA, 0.8s 60 cm
16
The samples of projection data obtained from 0 to 360 degrees The samples of cross sectional image Cement plaster Air Air bubble
17
From the result, the miniature computed tomography is capable of constructing a cross sectional image with an ease and cost-effective technique. From the result, the miniature computed tomography is capable of constructing a cross sectional image with an ease and cost-effective technique. Moreover, 3D model reconstructed from these cross sectional images will be performed in the further study. Moreover, 3D model reconstructed from these cross sectional images will be performed in the further study.
18
LOGO Department of Electronics, Faculty of Engineering King Mongkut’s Institute of Technology Ladkrabang, Thailand
19
LOGO
20
Wavelength 540 nm Green Tone
21
Distance 14 cm Increase distance Close to middle ball
23
Salt & Paper noise
24
Edge of image
25
Overlap
27
X-ray tube Object Enlarge size Shadow Far Similar size Shadow Near 60 cm
28
Overlap
29
Phenomenon Beam Hardening Air bubble