Download presentation
Presentation is loading. Please wait.
Published byAnnabelle Gibbs Modified over 9 years ago
1
Formula SAE Flow Testing Device Team members: Keith LundquistLong DangAdam Barka Vu NguyenJasper Wong Industrial Advisor:Academic Advisor: Evan Waymire, PEChien Wern, PhD
2
Table of Contents I.Mission Statement II.Milestone III.Product Design Specification IV.External Search V.Internal Search VI.Concept Design
3
Mission Statement Design and build a device capable of measuring Flow coefficient for the intake and exhaust valves Mass flow for throttle body, and engine head To get VMS team into the top place finish.
4
Milestone DONE PDS External/Internal Search Final Concept Evaluation Initial Design Product delivered to Customer May 28 th, 2012 Final Report June 6 th, 2012 TARGET DONE
5
Product Design Specification Key design criteria Capacity: 0 to 150 cfm at 28 in H 2 O Repeatability: %5 repeatable Noise < 85dB Footprint < 50in x 50in Maintenance: parts are easy to inspect and replace Cost: <$3500
6
External Search Pros Cheap (2000$) Small, portable Cons Low reliability Single direction flow Not enough functionality Test piece DAQ Home build device
7
External Search Pros Able to measure wide range of volume (600cfm) High accuracy Reliable Cons Too expensive (>$5000) Need to be modified Unable to add more functions Industry device
8
Internal Search OrificeNozzle FLOW METHOD
9
Internal Search Laminar Flow Element Ventury
10
Internal Search Axial Fan 124 CFM 35$ Air Pump Centrifugal Blower 2000 CFM 965$ Vacuum Motor 155 CFM 99$
11
Internal Search ADLink Built into PC 16-channels $600 DAQ Data Logger Stand-alone 8-channels $1000 NI Connected to PC 16-channels $500
12
Concept Design