RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER TO PHOTONS IN THE ENERGY RANGE 10 – 120 MeV Stockholm.

Similar presentations


Presentation on theme: "RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER TO PHOTONS IN THE ENERGY RANGE 10 – 120 MeV Stockholm."— Presentation transcript:

1 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER TO PHOTONS IN THE ENERGY RANGE 10 – 120 MeV Stockholm University, Uppsala University, Lund University (Klas Marcks von Würtemberg) Status report, PAC Nuclear Physics, Lund, November 9, 2010

2 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER  PANDA (@FAIR)  Aim of project  Review  Experimental set-up, analysis  Results and current situation  Future Outline Tord Johansson Erik Thomé Kjell Fransson Pawel Marciniewski Magnus Wolke Bent Schröder Kurt Hansen Magnus Lundin Jason Brudvik Lennart Isaksson Klas Marcks von Würtemberg Linda Gerén Per-Erik Tegnér Christoph Bargholtz Pia Thörngren Engblom Olle Lundberg

3 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER PANDA (@FAIR)  Study of gluonic excitations and the physics of strange and charm quarks  Demands on calorimeter: High resolution and low energy threshold  Calorimeter material: Scintillating PWO-crystals cooled to -25 ° C

4 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Aim  Determine the energy resolution and spatial resolution of a realistic set-up of a 5x5 matrix of PWO-crystals.  VPT (vacuum photo triods) as light converters  Flash-ADC read-out system  Support structure: Carbon fibre alveoli  Pre-shaped wrapping  Crystal shape (slightly tapered)

5 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Review 2007  3x3 matrix, straight crystals  PM-tubes, Peak sensing ADCs Today 2010  5x5 matrix, tapered crystals  Carbon fibre alveoli  Provisional support structure  PM-tubes, Peak sensing ADCs / Flash-ADC

6 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Tomorrow (2011)  VPTs will be used. A complete setup can be tested.  Adjustable support structure planned Current setup representative of central part of forward end-cap Peripheral part of forward end-cap

7 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER  5x5 PWO crystals  Climate chamber -25 °C  PM-tubes (anode signal)  Preamplifiers Cave  2x16 chn shapers 0.8 μs  Peak-sensing ADC DAQ Radiator CaveDaq e-e- e-e- γ B Focal plane  62 detectors  δE ~ 1 MeV (std 0.29 MeV)  Covers 13 – 64 MeV Schematic view of experiment 164.7 MeV

8 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Data and calibration Novosibirsk function 2nd degree polynomial fit

9 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Results Threshold 0.5 MeV Beam: central crystal Tagger plane not in focus PWO 5x5

10 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Independent measurement of focal plane resolution with CATS  500 kg NaI in 7 segments  Calibrated by 15.11 MeV line of Carbon Revealed features  Decreased resolution of focal plane below 35 MeV  Nominal energies of focal plane detectors scaled by a factor 1.075

11 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Independent measurement of tagged photon energies with CATS Fitting region Tagger detector 61 Tagger detector 8 E_CATS=0.18+0.94*E_Nominal

12 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Contribution from focal plane summed quadratically to contribution from CATS Contribution from CATS NaI - CATS

13 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Threshold: 0.5 MeV Results after deconvolution PWO 5x5

14 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Threshold: 0.5 MeV Beam off centre Beam position PWO 5x5

15 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Position of a photon striking the detector estimated by weighted average of energy depositions (non- linear weights) Fine structures of estimated position when deposited energy is spread over few crystals. Spatial resolution 13 - 30 MeV 40 - 63 MeV

16 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Spatial profile of beam measured with ccd-camera Total width: 14 mm Standard deviation: 2.9 mm Contribution from beam width to measured spatial resolution small if quadratical summing assumed :

17 RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER Future  Next experiment: March 2011  New light converters: Vacuum triods Thank you for your attention!  Increased energy resolution of focal plane below 35 MeV would be valuable. From the projects point of view:


Download ppt "RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER RESPONSE OF THE PANDA ELECTROMAGNETIC CALORIMETER TO PHOTONS IN THE ENERGY RANGE 10 – 120 MeV Stockholm."