Presentation is loading. Please wait.

Presentation is loading. Please wait.

2013 California Statewide Critical Peak Pricing Evaluation Josh L. Bode Candice A. Churchwell DRMEC Spring 2014 Load Impacts Evaluation Workshop San Francisco,

Similar presentations


Presentation on theme: "2013 California Statewide Critical Peak Pricing Evaluation Josh L. Bode Candice A. Churchwell DRMEC Spring 2014 Load Impacts Evaluation Workshop San Francisco,"— Presentation transcript:

1 2013 California Statewide Critical Peak Pricing Evaluation Josh L. Bode Candice A. Churchwell DRMEC Spring 2014 Load Impacts Evaluation Workshop San Francisco, California May 2014

2  Introduction and comparison of rates  PG&E Results  SCE Results  SDG&E Results Appendix: Evaluation methodology 1 Presentation overview

3  PG&E called 8 events  SCE called 10 events  SDG&E called 4 events  Each utility calls event days based on their system conditions  SDG&E’s events last from 11 AM to 6 PM while PG&E’s and SCE’s last from 2 to 6 PM 2 Event days are different across the three utilities  System load patterns across utilities are not always coincidental, particularly for Northern and Southern California  Comparisons in impacts between the utilities should be made with caution  No event day was common to all utilities.

4  PG&E’s average load reduction per customer was 8.6% (22.4 kW).  SCE’s average load reduction per customer was 5.8% (14.2 kW).  SDGE’s average load reduction per customer was 6.9% (18.4 kW). 3 Average event day percent reductions by utility are in a similar range

5 4 2013 reductions were slightly larger than last year’s UtilityYear Number of Events Accts Temp (°F) Reference Load (MW) Load Impact (MW) Percent Impact (%) PG&E 201091,65090.2592233.9% 201191,75088.1473285.9% 201291,62786.5437306.9% 201381,71790.8448388.6% SCE 2010124,10084.71077312.9% 2011123,00084.7615355.7% 2012122,50887.3554335.9% 2013102,49587.3613365.8% SDG&E 201041,35081.3357195.3% 201121,30086.2359195.2% 201271,11780.4268166.0% 201341,09584.1293206.9%  PG&E and SDG&E average event conditions were hotter  PG&E showed the largest jump in reductions from 30 to 38 MW, due to both more participants and larger percent reductions  The customer mix has evolved substantially over time but response has been consistent  Even when enrollments seem similar, customers exit and join, leading to changes

6 PG&E Specific Results 5

7 6 PG&E’s average load reduction was 8.6%, or 38.4 MW, across the 8 events in 2013

8 7 PG&E detailed event load impacts * Unofficial event ** Avg. event estimates do not include the unofficial event

9  Manufacturing; Wholesale & Transport; and Agriculture, Mining, & Construction accounted for 41% of the load and over 75% of impacts  While the Offices, Hotels, Finance, Services sector had the most load, 36%, it accounted for only 16% of program impacts 8 PG&E’s demand reductions were concentrated in two industries

10  On a percentage basis, reductions were similar for large and smaller customers alike 9 Not surprisingly, the largest customers account for a large share of the demand reductions Avg.

11 10 Ex ante estimates relied on available historical data 1. Model loads absent DR as a function of temperature and month 2. Estimate loads absent DR for 1-in-2 and 1-in-10 conditions 5. Combine loads and percent reductions 3. Model historical percent impacts as a function of weather 4. Estimate percent impacts under 1-in-2 and 1-in-10 conditions  There is no robust empirical data about how medium customers will respond when default to CPP  Percent impacts were based on the historical 2012–2013 industry specific percent load reductions as a function of weather.  Medium reference loads were developed by using a representative sample of customers and estimated by LCA and industry.  The industry specific percent load reductions were then applied to medium customer loads.

12 11 Ex ante percent reductions are inline with historical percent reductions  2012 and 2013 events used as basis for ex ante  Estimates were produced by LCA  Comparison is based on:  Historical customers  Same event window and historical events  Assumes percent reductions of new customers in LCA will be similar

13 12 Reference loads align with historical loads  References loads were separately estimated for large and medium customers by LCA  Comparison is based on:  Historical customers  Same event window and historical events  New large customers are assumed to be similar to old ones

14 Weather Year Year AccountsReference Loads (MW)Percent Reductions Aggregate Impacts (MW) 2012 Estimates 2013 Estimates 2012 Estimates 2013 Estimates 2012 Estimates 2013 Estimates 2012 Load Impact (MW) 2013 Load Impact (MW) 1-in-10 20141,7961,673603.6535.97.3%7.7%44.141.5 20151,8152,657609.7847.17.3%8.4%44.670.9 20161,8152,781609.9886.37.3%8.3%44.673.7 2017-20231,8152,783609.9886.97.3%8.3%44.673.7 1-in-2 20141,7961,673622.6515.58.0%7.0%49.736.3 20151,8152,657628.9810.98.0%7.6%50.261.3 20161,8152,781629.0848.88.0%7.5%50.263.8 2017-20231,8152,783629.0849.48.0%7.5%50.263.9 13 Comparison of 2013 ex ante year estimates to prior year estimates  Differences are mostly due to changes in the enrollment forecasts  2014 ex ante impacts align well with the 2013 avg. event response  Over time, customers who reduce demand have tended to remain on CPP, while those less likely to respond have migrated elsewhere

15 Weather Year Year Enrolled Accounts Avg. Reference Load (MW 1 to 6 PM) Avg. Estimated Load w/ DR (MW 1 to 6 PM) Avg. Load impact (MW 1 to 6 PM) % Load Reduction (%) Weighted Temp. (°F) 1-in-10 August System Peak Day 201350644.141.52.65.9%97.6 201450644.141.52.65.9%97.6 201515,084583.7548.834.96.0%97.3 201616,237624.8587.836.95.9%96.8 201727,6551062.01001.061.05.7%95.8 201825,330972.9916.856.05.8%95.9 201921,194812.5766.146.45.7%95.6 1-in-2 August System Peak Day 201350641.238.92.35.5%95.0 201450641.238.92.35.5%95.0 201515,084543.2513.130.15.5%94.9 201616,237582.9551.031.95.5%94.6 201727,655996.7943.852.95.3%94.5 201825,330912.4863.948.65.3%94.5 201921,194763.5723.240.25.3%94.4 14 Due to limited empirical data, ex ante estimates for medium customers have a higher degree of uncertainty

16 SCE Specific Results 15

17 16 SCE’s average load reduction was 5.8%, or 35.5 MW, across the 10 event days in Jul-Sep 2013

18 17 SCE detailed event load impacts

19  Manufacturing accounts for roughly 27% of customers and load but provides 68% of the reductions  Wholesale and transport accounts for 17% of the customers and load but provides 12% of the reductions 18 Two industry groups account for 87% of the demand reductions

20 19 At SCE, larger customers not only have more load but also deliver larger percent reductions Average

21 20 Ex ante percent reductions line up with historical percent reductions  2012 and 2013 events used as basis for ex ante  Estimates were produced by area  Comparison is based on:  Historical customers  Same event window and historical events  Assumes percent reductions of new customers by area will be similar

22 21 Comparison of 2013 ex ante year estimates to prior year estimates  2013 estimates reflect the evolution of SCE’s default CPP customers and more recent historical data  2014 ex ante impacts align well with the 2013 avg. event response, 35.5 MW  Over time, customers who reduce demand have tended to remain on CPP, while those less likely to respond have migrated elsewhere Weather Year Year 2012 Reference Load 2013 Reference Load 2012 Percent Load Impact 2013 Percent Load Impact 2012 Accounts 2013 Accounts 2012 Load Impact (MW) 2013 Load Impact (MW) 1-in-102014222.0263.84.2%5.7%3,0992,51228.837.7 1-in-102015222.0263.84.2%5.7%3,1302,47329.137.1 1-in-102016-2023222.0263.84.2%5.7%3,1412,47329.237.1 1-in-22014217.6257.64.4%5.6%3,0992,51229.636.0 1-in-22015217.6257.64.4%5.6%3,1302,47329.935.5 1-in-22016-2023217.6257.64.4%5.6%3,1412,47330.035.5

23 SDG&E Specific Results 22

24 23 SDG&E’s average weekday load impact was 6.9%, 19.6 MW

25 24 SDG&E detailed event load impacts

26  Offices made up 46% of the load at SDG&E (versus 36% and 23% at PG&E and SCE). They also reduced demand more.  Institutional and Wholesale & Transport segments still performed the best and accounted for a substantial share of impacts. 25 SDG&E had more customers and load in the offices sector

27 26 At SDG&E, larger customers also accounted for a large amount of the demand reductions Average  On a percentage basis, there is no discernable pattern of responsiveness by size

28 27 Ex ante percent reductions are inline with 2012–2013 historical percent reductions  2012 and 2013 events used as basis for ex ante  Comparison is based on:  Historical customers  Same event window and historical events

29 28 Ex ante reference loads align with historical loads

30 29 Comparison of 2013 ex ante year estimates to prior year estimates  Differences are due to small changes in the estimated percent reductions  The 2013 estimates incorporate more historical data (2012 and 2013 events v. 2012 alone) Weather Year Year 2012 Reference Load 2013 Reference Load 2012 Percent Load Impact 2013 Percent Load Impact 2012 Accounts 2013 Accounts 2012 Load Impact (MW) 2013 Load Impact (MW) 1-in-10 2014269.4274.35.9%6.7%1,0971,14617.421.1 2015269.4274.35.9%6.7%1,1141,16417.721.4 2016269.4274.35.9%6.7%1,1281,19317.922.0 1-in-2 2014260.5261.15.9%6.2%1,0971,14616.918.5 2015260.5261.15.9%6.2%1,1141,16417.218.8 2016260.5261.15.9%6.2%1,1281,19317.419.2

31 30 Due to limited empirical data, ex ante estimates for medium customers have a higher degree of uncertainty Weather YearYear Enrolled Accounts Avg. Reference Load Avg. Estimated Load w/ DR Avg. Load Impact % Load Reduction Weighte d Temp. (11 AM - 6 PM MW) (%) (°F) 1-in-10 August System Peak Day 20130----- 20140----- 20159,025448.6428.420.14.5%84.3 20167,387365.0345.619.35.3%84.3 20176,640327.2307.519.76.0%84.3 1-in-2 August System Peak Day 20130----- 20140----- 20159,025428.7410.917.84.2%81.9 20167,387348.9331.917.04.9%81.9 20176,640312.9295.517.35.5%81.9  Impacts are based on large default CPP, but adjusted for differences in the industry mix and size of medium customers

32 For comments or questions, contact: Josh L. Bode, M.P.P. jbode@nexant.com Candice A. Churchwell, M.S. cchurchwell@nexant.com Nexant, Inc. 101 Montgomery St., 15 th Floor San Francisco, CA 94104 415-777-0707

33 Appendix Evaluation Methodology and Validation 32

34  CPP rates introduce two changes:  Higher prices on peaks hours of critical days (CPP adder) designed to encourage customers to reduce demand  Rate discounts during non-event days to offset CPP adder  The impact of the rate discount on non-event days is not estimated for three reasons:  Focus for planning and operations is on the dispatchable demand reductions that can be attained  The pre-enrollment data needed to quantify non-event day impacts is too distant (four or five years prior)  Most non-event day impacts, if any, are now embedded in system load forecasts (and not incremental)  Analyses in 2010 and 2011 did not find statistically significant impacts due to the rate discount 33 The focus on the evaluation was on the dispatchable event day response

35  For industrial customers (and commercial customers without a successful match), impacts were estimated using customer-specific regressions.  Electricity usage patterns on non- event days are used to estimate what customers would have done if an event had not been called (a within- subjects method).  Approach works:  For very large customers (where a valid control group may not be possible)  Customers with low weather sensitivity  When non-event day conditions are similar to event days (often not the case)  For commercial customers, the estimates rely on difference-in- differences panel regressions.  Observe how the control and participant groups behave during both event and non-event days.  Method is less likely to be an artifact of the model selected. It better captures behavior during event days without comparable weather conditions.  Approach works best with:  Ample control group candidates  There are many observable variables  Non-event or pre-enrollment data  A small number of customer does not dominate the load and/or reductions  These use an external control group and non-event day data.  This approach was used for weather-sensitive commercial customers: institutional/governmental industries, offices, hotels, finance, services, and retail stores.  This approach was used for less weather-sensitive industrial customers, and for those commercial customers that could not be matched with a suitable control customer. The ex post evaluation used the best available method for commercial and industrial customers 34

36  PG&E example using raw aggregated data for summer weekdays without any modeling  Some of the noise is explained through day of week, seasonal effects and customer specific weather  Generally customer specific regression are better suited for industrial customers Individual Regressions – some 2013 events lacked comparable non-event days 35

37 36 Difference-in-differences  Difference-in-differences uses information from a control group and information for hot non-event days  Hourly loads for a well-matched control group nearly mirror the loads of the CPP population on event-like days.  These small differences are subtracted from the difference between control and CPP population loads on actual event days – the difference-in-differences.

38 37 The non-event control days were selected to match event conditions as closely as possible  We matched non-event days to historical events based on system loads, temperature, day of week and program year.  Comparable proxy days are not available for some days with very extreme weather.

39 38 The validation tests show that the hybrid method out- performs other alternatives  Impacts are estimated for the proxy event days, using the same models and process used for the ex post evaluation. If a method is accurate, it produces impact estimates for the average event that center on zero and are insignificant because, in fact, there is no event.  The impacts when CPP event day prices were not in effect are near zero and the reference loads estimated via the control group match the CPP participant loads.


Download ppt "2013 California Statewide Critical Peak Pricing Evaluation Josh L. Bode Candice A. Churchwell DRMEC Spring 2014 Load Impacts Evaluation Workshop San Francisco,"

Similar presentations


Ads by Google