PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter.

Similar presentations


Presentation on theme: "PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter."— Presentation transcript:

1 PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter Mask Supplied Air Job Hazards Y es Job Hazards Y es Access and EgressMoving Parts Activities of OthersNoise Adverse WeatherRail Movement Chemical ExposureSharp Edges ElectricitySlips, Trips, and Falls FatigueStatic Electricity Fire and ExplosionTrip Injuries Ground ContaminationTrapped Pressure Manual HandlingWorking at Height Other: References / Documents  ASTM D5188 AreaUnitOperating Procedure #Certified byRevision #DatePage 3LabOPS-LB-PT-00510.11.20111 of 2 Automatic Determination of the Vapor-Liquid Ratio Temperature of Gasoline by Grabner MiniVol LVR EnvironmentalSpecial Instructions Automatic Determination of the Vapor-Liquid Ratio Temperature of Gasoline by Grabner MiniVol LVR 1 Place sample container (must be 1 liter) in chiller for at least 30 minutes prior to beginning test. IMPORTANT: Test must be performed on first test specimen withdrawn from the sample container. 2Remove sample from bath and wipe container dry. 3 Verify that the container is 70-80% full: 4Remove sample cap momentarily, reseal and return to chiller. 5With sample again at 32-34°F (0-1°C), remove container from cold bath and wipe dry. 6Remove cap, reseal and shake sample vigorously before returning to chiller for a minimum of 2 minutes. 7Press RUN on the analyzer to start heating sample chamber to 167°F. 8Turn on vacuum pump to evacuate sample chamber (pump has no power switch – plug in to start). 9Verify chamber pressure is ≤ 0.1 kPa (0.01 psi). 10 Remove chilled syringe and n-pentane bottle from cold bath. NOTE: Time between opening sample container and securing syringe into analyzer must not exceed 1 minute. 11Dry container and insert chilled syringe into sample drawing a 4 ml bubble free aliquot into syringe barrell. EquipmentMaterials and Reagents  Grabner MiniVol LVR Analyzer  TECA AHP-1200CPV Solid State Cold Plate (32° - 34°F)  Vacuum Pump  Syringe – Kloehn, Part # 17584  Pentane (≥ 99% purity) Scope / Objective This procedure covers the determination of the temperature at which the vapor formed from a known volume of air-saturated gasoline produces a pressure of 1 atm in an evacuated chamber of fixed volume. Note: This procedure is only valid at the time of printing. The control version can be found on the Meraux Refinery intranet. Completed Date:Prepared By:Approved By:

2 AreaUnitOperating Procedure #Certified byRevision #DatePage 3LabOPS-LB-PT-00510.11.20112 of 2 Automatic Determination of the Vapor-Liquid Ratio Temperature of Gasoline by Grabner MiniVol LVR Cont. 12Insert syringe tip into Luer bore on right side of instrument turning slightly to lock into place. 13Start measurement by pressing RUN. 14 Measuring chamber will be automatically flushed with sample prior to injecting exact amount of sample for testing – once testing is completed result data is displayed. 15Ensure result for pentane is within limits (95.9–97.9°F). 16Repeat Steps 7-13 for gasoline sample. 17Once sample analysis is complete, record result to 1 decimal place. 18Unplug vacuum pump. 19Remove syringe from analyzer, place in plastic bag and return to chiller. Note: This procedure is only valid at the time of printing. The control version can be found on the Meraux Refinery intranet. Completed Date:Prepared By:Approved By:


Download ppt "PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter."