High Pressure Motor Valve
2
High Pressure: 1” & 2” Screwed connection rated to 4000 psi standard. Can be rated up to 6000 psi. Motor: One that imparts motion.
3
High Pressure Motor Valve FIELD REVERSIBLE TOPWORKS OPEN YOKE STUFFING BOX No adjustment No lubrication Teflon – low friction POSITION INDICATOR BALL AND CONE SEAT
4
High Pressure Motor Valve
5
Field Reversible Topworks
6
High Pressure Motor Valve
7
High Pressure Motor Valves
8
65 Topworks 65 sq. in. diaphragm P. O. service Extends 1” HPMV with ½” inner valve to 4000# W.P. Extends SMS valve to 4000# W.P. Available for 1”, 2” and non-freeze HPMV Wide spring adjustment range
9
Manual Valve Positioner Used as a limit for valve stem travel Used to manually open the valve on unit start-up Each revolution of the handle moves the stem 1/16” ¾” max. stem travel
10
Pneumatic Valve Positioner Maintains stem position through changes in force on stem Provides repeatable stem placement
12
Soft Seat 15/16” port in 1” valve 1-1/2” port in 2” valve Maximum pressure drop: 300 psi On / Off service only
13
Improving Service of HPMV’s Size Valve Properly. Valve should operate between 50% and 80% of its capacity Use quick opening trim in erosive service. Use Carbide or Zirconia trim in highly erosive service. Use Equal Percentage trim for controlling pressure or flow rate.
14
SNAP NOMINAL =%AGE Trim Characteristics
15
Ceramic Trim Carbide Zirconia
16
Maximum Pressure Drop 1” Motor Valves 2” Motor Valves I.V. Throttle Relief 1/2” 3/8” 1800 2700 3600 5400 1” 3/4” 900 2000 1800 4000
17
Piston Balanced High Pressure Motor Valve Full line size port Balanced plug Soft seat with metal to metal backup Field reversible topworks Equal Percentage Trim Bubble tight shut-off Sizes available: 2”, 3,” 4” & 6”
18
Maximum Working Pressure: Connection W. P. 2” Screwed 4000 psi. 2” Flanged ANSI 1500 (3705 psi*) 3” Flanged ANSI 600 (1480 psi*) 4” Flanged ANSI 600 (1480 psi*) 6” Flanged ANSI 600 (1480 psi*) * For working pressure vs. working temperature of these flanges see ANSI B16.2. Piston Balanced High Pressure Motor Valve
19
1” Non-Freeze Dump Valve Inner valve located to utilize vessel heat to prevent freezing 1” NPT inlet & outlet 2” NPT vessel mounting Up to 4000 psi W.P. 1/8” –1/2” inner valves available
20
Non-Freeze Dump Valve Vertical Separator
21
Horizontal Separator “Stinger” Non-Freeze Dump Valve
22
Metering Valve Calibrated in 1/64” equivalent orifice diameter Available in 1”& 2” standard HPMV Also available in 2” & 3” piston balanced HPMV
23
Piston Balanced Metering Valve
24
Optional Vee Packing Glass filled Teflon Virgin Teflon Carbon filled Teflon Glass filled Teflon Max. Temperature: 500 o F