Download presentation
Presentation is loading. Please wait.
Published byBethanie Holt Modified over 9 years ago
1
AdV cryotrap: cryostat surface is partially exposed to the near mirror (input ~ end). Its seismic shaking is amplified by LN2 boiling. The rest of vacuum chamber walls could be baffled out
2
CRYOTRAPS INNER DIAMETER IS TO BE FIXED Present figure of trap inner diameter is 0.86m. It could be enlarged to reduce the view factor or equipped with (metallic) baffles; on the contrary it could be narrow (0.7m for instance) for easier mechanical design, reduced cost and LN2 consumption Step 1, today: calculation method assessment Step 2: level of bubbles induced seism shall be estimated and comapred to the allowed limit calculated above (also the ‘baffles’ could be shaken above the ‘normal ground level’) -
3
Related documents: A plot about the bubbling of the present small trap: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/24753_bubbletest_level2.gif/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/24753_bubbletest_level2.gif/ Seism measurement: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/seism_LARGEmicroseism.png/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/seism_LARGEmicroseism.png/ Last AdV cryotrap drawings: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/last- cryotrap-drawings/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/last- cryotrap-drawings/ Baffles calculation by JYVinet: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/cryox.pdf/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/cryox.pdf/ Coupling factor estimation K ~ 2E-25: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/Kcalc.pdf/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/Kcalc.pdf/ Summary doc about backscattering upconverions by Irene: https://workarea.ego- gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/minidocIrene_AdV_CryoT_BSnoiseProjection.doc/ https://workarea.ego- gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps-11feb2010/minidocIrene_AdV_CryoT_BSnoiseProjection.doc/ Tube shaking test by Stefano: https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/Braccini_DiffusedLight_12022008.ppt/ https://workarea.ego-gw.it/ego2/virgo/advanced-virgo/vac/diffused-light-vs-cryotraps- 11feb2010/Braccini_DiffusedLight_12022008.ppt/
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.