Presentation is loading. Please wait.

Presentation is loading. Please wait.

RGA Global Headquarters Lateral System Analysis Study

Similar presentations


Presentation on theme: "RGA Global Headquarters Lateral System Analysis Study"— Presentation transcript:

1 RGA Global Headquarters Lateral System Analysis Study
Chesterfield, MO Natasha Beck | Structural

2 Area Considered Seismic expansion joints create four separate structural buildings E.J.= 2 ½”

3 Lateral Elements Modeled
Two Stage Analysis procedure Office: brace frames Parking garage: shear & foundation walls

4 Modeling Process Braced Frames Shear Walls Two-Stage Analysis
Period Reactions Shear Walls Two-Stage Analysis ASCE Combination Factor Combined Model Braced Frame Reactions Converted by Two-Stage Analysis Applied to top of shear walls

5 Modeling Considerations
Base conditions Brace frames-pinned base Shear walls-pinned base Rigid Diaphragms Office-composite concrete T=6 ½” Parking-slabs 7 ½” to 9 ½” Irregularities Non-parallel systems irregularity in parking garage

6 Force Distribution Weight at the Level 01 interface
Penthouse story forces

7 Animations

8 Moment Diagrams Braced frame controlling case: 0.9D+1.0E Seismic Y-5%X
Critical Braced Frame Braced frame controlling case: 0.9D+1.0E Seismic Y-5%X

9 Member Utilization Ratios
Critical Braced Frame Critical Shear Wall Braced frame controlling case: 0.9D+1.0E, Seismic Y-5%X Shear wall controlling case: 0.9D+1.0W, Wind Case 1-Y

10 Is the System Acceptable?
System and components are adequate for strength Foundation is acceptable Serviceability-Drift Wind: Meets both H/400 and H/600 drift limits found in ASCE 7 commentary Seismic: Meets allowable story drift standards Max. concrete building drift= < ½*EJ=1.25” System is acceptable