Presentation is loading. Please wait.

Presentation is loading. Please wait.

Haluk Örs Mikro Inverter Ve Optimizer Nerede Gerekli?

Similar presentations


Presentation on theme: "Haluk Örs Mikro Inverter Ve Optimizer Nerede Gerekli?"— Presentation transcript:

1 Haluk Örs Mikro Inverter Ve Optimizer Nerede Gerekli?

2 DC Optimizasyonlu İnverter Çözümü Inverter Monitoring Portal Power Optimizer Power Optimizer 2:1 configuration 04/05/2015

3 String İnverterlar ile Farkı Klasik İ nverter MPPT per entire string Power losses due to module mismatch Optimizasyonlu MPPT per module Maximum power from each module individually String level MPPT – All modules receive the same current, regardless of their individual MPP String level MPPT – All modules receive the same current, regardless of their individual MPP Module-level MPPT – Current & voltage adjusted per module Module-level MPPT – Current & voltage adjusted per module 04/05/2015

4 Nerelerde İhtiyaç Duyulur? Tolerance MismatchPartial ShadingSoiling Thermal MismatchInstallation angleAging Mismatch 04/05/2015

5 Yararları Best-in-class Safety Reduced BoS Costs More Energy Asset Management 04/05/2015

6 Yararları PV Asset Management Protect your asset with full visibility of system performance & remote troubleshooting 04/05/2015

7 Yararları PV Asset Management Monitoring at the module level – free for lifetime Fault detection pinpointed on a virtual site map Automatic alerts on system issues 04/05/2015

8 Yararları Longer strings for Reduced BoS cost Fewer strings  Less wiring, combiner boxes, fuses, etc.  Up to 50% reduction in BoS cost 04/05/2015

9 Yararları More energy - MPPT per module Maximum power from each module individually Issues with individual modules isolated from impacting string 04/05/2015

10 Yararları More energy - MPPT per module Mitigates unpredictable environmental changes Detects defective modules, improve up-time 04/05/2015

11 Yararları Best-in-class safety Automatic module DC shutdown when inverter is not operating No high V DC during installation or maintenance 04/05/2015

12 Inverters account for only ~10% of the system cost but, Inverters influence ~30% of system cost Inverters manage 100% of system production Inverters control O&M expenses through PV asset management solutions 04/05/2015

13 İzmir 500 kWp DC optimizasyonlu İnverter Uygulaması Capacity: 500 kWp Location: Izmir, İ zmir Ataturk Industrial Zone (IAOSB), Turkey Inverters: 26 X SolarEdge SE17kW Power Optimizers: 962 X SolarEdge P600 Installed by: RENKO ENERJ İ, İ stanbul

14 Teşekkürler.. 04/05/2015


Download ppt "Haluk Örs Mikro Inverter Ve Optimizer Nerede Gerekli?"

Similar presentations


Ads by Google