Supervisor: Mr. Shahar Porat Written by: Oren Hemo Hadar Zrihan High Speed Digital System Lab Spring semester 2014 Final Presentation
2
Motivation Project’s goals Project’s specifications Technology comparison (inductive VS inductive resonance) Circuit topology and architecture ◦ Oscillator ◦ TX driver ◦ Power delivery component: Coil design and resonance tuning ◦ Rectifier ◦ Loop calibration method (using Galileo) Results
3
With the market growth of handheld devices and wearable devices, a wireless charging technology becomes very important to bring good user experience for the end users.
4
Inductive resonance seems to be the next generation technology that will bring spatial freedom to user when applying wireless charging.
5
Develop a power delivery system based on Magnetic resonance technology, with a compensation loop to reach peak power delivery at resonance frequency.
6
Achieving transfer of maximum efficiency more than 50% at resonance frequency. planning a board: ◦ Understanding each component use and ability ◦ placing each component’s inputs and outputs on the board
7
Charger’s model The designed model as electrical lumped circuit
8
D1 D2 z Primary Secondary I1I1 I 2(t) H 0.1110 Eff % 10 100 1 D2 = D1 D2 = D1/10 I 1 (t) z/D1
10
Oscillator DriverLC Galileo LC Diode Bridge Load
11
Location: TX unit Freq. range 1.5-3 MHz Resistors ratio: Frequency calc.:
12
Location: TX unit Its purpose is to amplify the voltage signal without drawing current from the source
13
TX coil RX component RX coil TX component
14
Location: TX and RX unit Coil: Made of Teflon Wire – 0.3 cm Number of loops – 8 Diameter – 11 cm Inductance of 4.2 uH Capacitor: 1 nF
15
Voltage definition in z Ratio between reflected and transferred voltage amplitude at the load Reflection coefficient with respect to z
17
S11 parameter האימפדנס בעל חלק מדומה חיובי מקסימלי עבור 2.09 MHz וערכו 4.8 uH
18
כאן חיברנו קבל בטור לסליל. האימפדנס בעל חלק ממשי טהור בקירוב מתקבל עבור 2.7 MHz S11 parameter Resonance frequency
19
כאן חיברנו קבל בטור לסליל. האימפדנס בעל חלק ממשי טהור בקירוב מתקבל עבור 2.2 MHz S22 parameter Resonance frequency
20
S21 – power delivery between the coils הגל העובר לסליל השני מקבל מקסימום ב -2.7 MHz וערכו -0.6 dB
21
Location: RX unit Consists a four-Diode bridge Input: ac signal from the RX coil Output: Positive voltage signal
22
Location: RX unit The load is 50 ohm Capacitor of 10 nF is parallel connected
23
Set initial frequency on 1.5 MHz Measure voltage on the RX load, save it. Increase freq. by 200 KHz (voltage by Measure voltage on the RX load, save it. Compare to previous value updown Current voltage is bigger Current voltage is smaller or equal Decrease freq. by 200 KHz and stop the loop
24
2.4 MHz 2.6 MHz max
25
2.8 MHz 3 MHz
26
2.1MHz 2.3MHz Rectifier output is highest for frequency =2.5MHz
27
2.5MHz Rectifier output is highest for frequency =2.5MHz max
28
We succeeded to build wireless power system with resonance frequency at 2.7 MHz We built a flow system to calibrate the power source to work in optimal frequency The efficiency of the system is higher than 90% in the resonance frequency