Detector for GlueX JLab PAC 23 Jan 20, 2003 Physics Beamline Hall D GlueX Detector Software Trigger Computing Environment PRL
2
What is needed? 9-GeV polarized photon beam Coherent bremsstrahlung beam Hermetic detector for multi-particle charged and neutral final statesCharged Solenoid-based detector Select events of interest with high sensitivity High DAQ rate capability with software trigger Analysis environment for successful PWA
3
Construction Site
4
Status of Civil Design Credible optics design Layout that provides room for detectors and access to equipment Beam containment proposal Concept for civil design GEANT Calculations show that the shielding satisfies radiation protection guidelines
5
Hall D site layout
6
Coherent bremsstrahlung beam Photon beam energy (GeV) Flux Delivers the necessary polarization, energy and flux concentrated in the region of interest P = 40% Photon beam energy (GeV) Linear Polarization
7
Gluonic excitations transfer angular momentum in their decays to the internal angular momentum of quark pairs not to the relative angular momentum of daughter meson pairs - this needs testing. GlueX will be sensitive to a wide variety of decay modes - the measurements of which will be compared against theory predictions. To certify PWA - consistency checks will be made among different final states for the same decay mode, for example: Should give same results For example, for hybrids: favored not-favored Measure many decay modes! Hybrid decays
8
GlueX detector
9
Solenoid ships from Los Alamos
10
Unloading at IUCF
11
Exploded view of the GlueX detector TARGETVTX CDC FDC CERENKOVPb-GLASS DET 12.00 The components are extracted by “4 ft” from each other for maintenance. TOF
12
Particle kinematics All particles Most forward particle p → X p → K + K ─ + ─ p
13
GlueX Detector
14
Central tracking Straw tube chamber Vertex Counter
15
Forward drift chambers
16
Charged particle resolution
17
Calorimetry Built by IU for BNL Exp 852 Pb Glass Barrel Mass 00 Pb/SciFi detector based on KLOE /E = 4.4 %/ √E, threshold = 20 MeV t = 250 ps
18
Particle identification Time-of-flight, Cerenkov counter, and constraints for exclusive events p → K*K*p, E = 9 GeV
19
Hall D Prototype (IHEP Run 2001) R. Heinz / IU
20
PID with Cerenkov and forward TOF TOF =100 ps resolution n= 1.0014n= 1.0024 p → K + K + p, E = 9 GeV
21
Acceptance is high and uniform Acceptance in Decay Angles Gottfried-Jackson frame: In the rest frame of X the decay angles are theta, phi assuming 9 GeV photon beam Mass [X] = 1.4 GeV Mass [X] = 1.7 GeV Mass [X] = 2.0 GeV
22
Trigger and DAQ Level 1 Level 3 Physics Signal Software-based Level 3 System Start @ 10 7 /s Open and unbiased trigger Design for 10 8 /s 15 KHz events to tape Level 1 trigger system With pipeline electronics
23
Trigger Rates Output of Level 3 software trigger
24
Luminosity limits GlueX raw rates will be well below currently running CLAS electron beam experiments
25
DAQ architecture 90 VME front-end crates Gigabit switch 200 Level 3 Filter Nodes 8 event builders 4 event recorders 4 tape silos 8 100-Mbit switches
26
Fully pipeline system of electronics Flash ADCs: 13000 channels TDCs : 8000 channels Deadtimeless Expandable No delay cables (Non-pipeline: Limits photon flux < 10 7 /s, incurs deadtime, requires delay cables)
27
Data Volume per experiment per year (Raw data - in units of 10 9 bytes) But: collaboration sizes! Ian Bird
28
Data Handling and Reduction CLASGlueX Event size5 KB Data volume100 TB/year1000 TB/year cpu speed0.4 GHz6.4 GHz cpu time per event100 ms15 ms cpu count150225 Reduction speed7 MB/s75 MB/s Throughput limitcpu speed Reduction time0.5 year0.4 year Data rate up by 10, computer costs down by > 5 GlueX Computing Effort ~ 2 x CLAS
29
Computing Model DAQ Level 3 Farm Event Reconstruction Calibration Physics Analysis Physics Data Tier “2” Centers Tier “1” Center (Jlab) Tier “2” Simulation Center 1 PB/year 0.2 PB/yr 0.2 PB 100 MB/s 70 MB/s 20 MB/s Physics Analysis 20 MB/s Monte Carlo
30
Detector designed for PWA Double blind studies of 3 final states p n X Linear Polarization m [GeV/c 2 ] GJ a2a2
31
Leakage An imperfect understanding of the detector can lead to “leakage” of strength from a strong partial wave into a weak one. STRONG: a 1 (1260) (J PC =1 ++ ) Break the GlueX Detector (in MC). Look for Signal strength in Exotic 1 -+ Under extreme distortions, ~1% leakage!
32
Ongoing R&D effort Solenoid – shipped to IUCF for refurbishment Tracking – testing straw chamber; fabricating endplate prototype (CMU) Vertex - study of fiber characteristics (ODU/FIU) Barrel calorimeter – beam tests at TRIUMPF; fabricated first test element of the Pb/SciFi matrix (Regina) Cerenkov counter – magnetic shield studies (RPI) Time-of-flight wall – results of beam tests at IHEP show ps (IU) Computing – developing architecture design for Hall D computing Electronics – prototypes of pipeline TDC and FLASH ADC (Jlab/IU) Trigger – Studies of algorithm optimization for Level 1(CNU) Photon tagger – benchmarks of crystal radiators using X-rays (Glasgow/UConn) Civil – beam height optimized; electron beam optics shortens length of construction; new radiation calculations completed (Jlab)
33
7 R.T. Jones, Newport News, Mar 21, 2002 Benchmarks of Diamond Crystals Stone 1407 Slice 1 (4mm x 4 mm X-ray rocking curve) Richard Jones / Uconn Stone 1482A Slice 2 (10mmx10mm X-ray rocking curve) High QualityPoor Quality
34
Straw Tube chamber work Graduate Students: Zeb Krahn and Mike Smith Built a -gun using a 10 Ci 106 Ru Source Getting coincidences with both cosmics and ’s gun cosmics ArCO 2 90-10 ArEthane 50-50 Carnegie Mellon University
35
Building a Prototype Endplate Build endplates as 8 sections with tounge and groove. Checking achievable accuracy
36
Barrel calorimeter prototyping Hybrid pmts can operate in fields up to 2 Tesla University of Regina Pb/SciFi prototype
37
FLASH ADC Prototype Paul Smith / IU 250 MHz, 8-bit FADC
38
Pipeline TDC = 59 ps TDC counts First prototype results: high resolution mode Jlab DAQ and Fast Electronics Groups
39
Cassel review of Hall D concluded “The experimental program proposed in the Hall D Project is well-suited for definitive searches for exotic states that are required according to our current understanding of QCD” “An R&D program is required to ensure that the magnet is usable, to optimize many of the detector choices, to ensure that the novel designs are feasible, and to validate cost estimates.” Working with input from many groups on electronics, DAQ, computing, civil, RadCon, engineering, and detector systems.