Presentation is loading. Please wait.

Presentation is loading. Please wait.

D-Series LED Wall Luminaires. DOUBLE THE POWER DOUBLE the lumens of the DSXPG unit from a single mounting point. Up to 12,000 lumens! LOWER TOTAL COST.

Similar presentations


Presentation on theme: "D-Series LED Wall Luminaires. DOUBLE THE POWER DOUBLE the lumens of the DSXPG unit from a single mounting point. Up to 12,000 lumens! LOWER TOTAL COST."— Presentation transcript:

1 D-Series LED Wall Luminaires

2 DOUBLE THE POWER DOUBLE the lumens of the DSXPG unit from a single mounting point. Up to 12,000 lumens! LOWER TOTAL COST Reduces overall fixture count at the entrance areas resulting in lower installation and material costs. ENHANCED OPTICS T5E optic is designed for parking garage entrances where IES recommends a minimum of 50 horizontal foot candles during the daytime hours. Key Benefits

3 REMARKABLE SAVINGS Saves over 50% in energy compared to a 250W metal halide system, and lasts 10X as long! INCREDIBLY LONG LIFE An expected service life of 100,000 hours (10+ years of 24/7 usage) means huge savings in maintenance costs. AMAZING VERSATILITY Ideal for applications requiring a 5fc horizontal minimum within the drive lanes (Example: City of Pittsburgh). Key Benefits

4 DUAL SWITCHING Dual switching and motion sensing options provide additional energy savings during daytime and periods of low occupancy. EXCEPTIONAL LUMEN MAINTENANCE LEDs maintain 87% of initial lumens over the 10 year period, unlike metal halide that loses over 40% of its initial lumens over its short life. Key Benefits

5 *Measured facing the drive aisle at 5 feet above the parking surface at the point of the lowest horizontal luminance. IES Recommended Practice Location Minimum Horizontal (fc)AverageUniformityMinimum Vertical (fc)* INDOOR PARKING 1.0n/a10:10.5 ENTRANCES – DAY 50n/a25 ENTRANCES - NIGHT 1.0n/a10:10.5

6 30x30’ Application 8’ Mounting Height T5M Distribution LLF Total.71 Application *Measured facing the drive aisle at 5 feet above the parking surface at the point of the lowest horizontal luminance. 5fc Minimum Requirement Location Minimum Horizontal (fc)AverageUniformityMinimum Vertical (fc)* PARKING DRIVE LANE 6.9410.141.7:11.38 DSXPGT 6 LED 10B700/50K T5M

7 Location Minimum Horizontal (fc)AverageUniformity PARKING DRIVE LANE54.556.31:1:1 Entrances 5X5’ Application 15’ Mounting Height T5E Distribution LLF Total.71 Application DSXPGT 6 LED 10B700/50K T5E

8 MOTION/AMBIENT SENSOR Pre-set to a low level setting of 34% power with 37% lumen output The built-in ambient sensor (photocell) is pre-set as high/off Control Options

9 DUAL SWITCHING Allows for half of the fixture to be turned off during periods throughout the day Control Options

10 CCT4000K and 5000K CRI4000K 70 min CRI, 5000K 67 CRI LUMEN MAINTENANCEL87 / 100,000 hrs (L92 / 50,000 hrs) DISTRIBUTIONS Types T5E (Entry), T5M (Medium), T5W (Wide), T5R (Rectangular), and ASY (Asymmetric) OPTICSPrecision acrylic refractive optics with UV inhibitor HOUSE-SIDE SHIELDField-installable low-profile house-side shields LUMEN RANGE6,800 – 12,700 lumens VOLTAGES (FREQUENCY)MVOLT (120-277), 347V, 480V (50-60 Hz) DRIVER SPECIFICATIONS90% efficient, <20% THD SURGE PROTECTION Tested to ANSI/IEEE C62.41-2002. Meets a minimum Category C Low FINISH MATERIALZinc-infused Super Durable TGIC powder coat STANDARD COLORSDark Bronze, Black, White, and Natural Aluminum WARRANTY5-Year Limited Warranty Key Specifications

11 COMMERCIAL FREEZERS LOW BAY APPLICATIONS COVERED WALKWAYS/CANOPIES Alternate Uses

12 D-Series LED Wall Luminaires


Download ppt "D-Series LED Wall Luminaires. DOUBLE THE POWER DOUBLE the lumens of the DSXPG unit from a single mounting point. Up to 12,000 lumens! LOWER TOTAL COST."