1 SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting A1: calibration A2: validation A3: Science products determination A4: Routine and.

Similar presentations


Presentation on theme: "1 SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting A1: calibration A2: validation A3: Science products determination A4: Routine and."— Presentation transcript:

1 1 SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting A1: calibration A2: validation A3: Science products determination A4: Routine and non-routine tasks A5: Scientific community interfaces

2 2 Royal Observatory of Belgium Concept Repartition of flows A E1E1 E2E2 C1C1 C2C2 Radiative Conductive

3 3Coatings Flat absorber : black painting (α s = 0.98, ε = 0.85) Solar reflector : White silicate painting (α s = 0.13, ε = 0.90) White Painting Black Painting Absorbing surface = 21 % of total surface Temperature of balance = 25°C :

4 4

5 B-USOC 18-19 juin 2009 Theoretical transfer function Picard/BOS electronics

6 6 #include #define Kmod 0.667 // #define beta 4143 // #define T0 298.15 // #define R0 100000 #define R15 75000 #define R13 75000 #define R18 100000 #define R19 100000 #define R23 10000 #define R29 82000 void BOS_V2T(double V1,double V2,double *T_OUT); int main(int argc, char *argv[]) { double T12_OUT[2],*T12_ptr; T12_ptr=&T12_OUT[0]; BOS_V2T(2,0,T12_ptr); printf("%lf\r\n",T12_OUT[0]); printf("%lf\r\n",T12_OUT[1]); system("PAUSE"); return 0; } void BOS_V2T(double V1,double V2,double *T_OUT) { double G11,G12,Vamp11,Vamp12,Vpp1,Vpm1,Rt1,T1; double G21,G22,Vamp21,Vamp22,Vpp2,Vpm2,Rt2,T2; double Valim; Valim = 8; //********************************************* Vamp12=V1; //********************************************* G11=1; G12=1+49400/R13; Vamp11=Vamp12/(Kmod*G12); Vpp1=Valim/(1+R19/R18); Vpm1=(G11*Vpp1-Vamp11)/G11; Rt1=Vpm1*R15/(Valim-Vpm1); T1=beta*T0/(T0*log(Rt1/R0)+beta); //********************************************* Vamp22=V2; //********************************************* G21=1; G22=1+49400/R23; Vamp21=Vamp22/(Kmod*G22); Vpm2=Vpm1; Vpp2=(Vamp21+Vpm2*G21)/G21; Rt2=Vpp2*R29/(Valim-Vpm2); T2=beta*T0/(T0*log(Rt2/R0)+beta); //********************************************* *T_OUT++=T1; *T_OUT =T2; } Theoretical transfer function Picard/BOS electronics

7 7 SOVAP - BOS (Bolometric Oscillation Sensor) A1: calibration A2: validation A3: Science products determination A4: Routine and non-routine tasks A5: Scientific community interfaces

8 8 Royal Observatory of Belgium Noise level with a 50 sec low pass filter, is about 1/10Hz Corresponding to a dynamic range of 500.000/1 1% of modulation = 1000 lux = 500Hz

9 9 Ramp and sin for scale factor T1 and T1-T2 Figure 4: Ramp and sin for scale factor Figure 5: T1 and T1-T2

10 10 Royal Observatory of Belgium Experiments

11 11

12 12 Flat Field (10sec) cycle On/Off

13 13

14 14

15 15

16 16

17 Star pointings October 6 & November 9, 2010

18 18

19 19

20 20

21 21

22 22

23 23

24 24

25 25

26 26

27 27

28 28

29 29

30 30

31 31

32 32 SOVAP - BOS (Bolometric Oscillation Sensor) A1: calibration A2: validation A3: Science products determination A4: Routine and non-routine tasks A5: Scientific community interfaces

33 33

34 34

35 35 The projection of PICARD satellite orbit. Here, we plotted the position of PICARD from 17:33 to 21:25 on July 11, 2010. This period is overlap with the solar eclipse. Red dashed line is from 17:33 to 18:41; Blue dashed line is from 18:41 to 20:12; Black dashed line is from 20:12 to 21:15. Two dark brown line marks the north and south limits of the greatest eclipse.

36 36

37 37

38 38

39 39

40 40

41 41

42 42

43 43

44 44

45 45

46 46 38 days records calibrated records, the linear trend has been removed.

47 47 Amplitude Fourier Spectrum of T1 and T2 computed using 38 days’ records 3 Minutes 99 Minutes

48 48 38 days records calibrated records, the linear trend has been removed. The Sub panel plotted 240 minutes data.

49 Three hours T1 measurements plotted on the map. The geocentric position was computed with the predicted orbit using WGS84

50 50 Three hours T2 measurements plotted on the map. The geocentric position was computed with the predicted orbit using WGS84

51 51 Thank you