Download presentation
Presentation is loading. Please wait.
Published byEthel Wright Modified over 8 years ago
1
Squeaking Hips by William L. Walter, Tim S. Waters, Mark Gillies, Shane Donohoo, Steven M. Kurtz, Amar S. Ranawat, William J. Hozack, and Michael A. Tuke J Bone Joint Surg Am Volume 90(Supplement 4):102-111 November 1, 2008 ©2008 by The Journal of Bone and Joint Surgery, Inc.
2
A computed tomography scan of bilateral ABG II ceramic-on-ceramic hip replacements (Stryker Howmedica Osteonics, Allendale, New Jersey). William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
3
Box plot comparing the volumetric wear rate of the squeaking retrievals with that of a historical control14. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
4
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
5
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
6
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
7
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
8
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
9
William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
10
This graph illustrates the Stribeck curves for different bearing combination materials. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
11
A screen capture of the acoustic analysis software. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
12
Modal analysis of a thin-walled generic acetabular shell resonating in the (2,0) mode. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
13
Graph representing the frequency of titanium shells resonating in the (2,0) mode. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
14
Natural frequencies for this titanium stem are shown with and without a ceramic head attached. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.
15
Graph of the natural frequencies of total hip replacement components. William L. Walter et al. J Bone Joint Surg Am 2008;90:102- 111 ©2008 by The Journal of Bone and Joint Surgery, Inc.