2
Verigy Restricted Appendix B – Autotransformer Page 2 Power Options with Autotransformer The Autotransformer E8005A is required for systems with: Small or Large test head, if the primary voltage is 440V or 480V. Large test head, if the primary voltage is 200V/208V AND power consumption exceeds 36kVA. Currently this is the case if more than 42 digital channel boards (of any type) are installed. Analog boards can be neglected. 1 Additional Support Rack is equivalent to 5 channel boards. Example: For systems with 2 Additional Support Racks up to 32 channel boards are supported without the transformer. The E8005A can be pro-actively ordered for large test head systems to allow for later upgrades by ticking a checkbox in the configurator.
3
Verigy Restricted Appendix B – Autotransformer Page 3 Autotransformer Front View Emergency Off Button Output Breaker ST2 Power On Lamp Cooling Fan Power Cable Outlet Fan Power Supply Control Transformer Power Output Cable
4
Verigy Restricted Appendix B – Autotransformer Page 4 Autotransformer Back View Input Breaker ST1 Cooling Fan Primary Power Cable Inlet Primary Power Connections PE
5
Verigy Restricted Appendix B – Autotransformer Page 5 Autotransformer Side View Input Breaker EMO Button Power OutJumper WiresPower In
6
Verigy Restricted Appendix B – Autotransformer Page 6 Autotransformer Top View Power Out Jumper WiresPower In Spare Fuses E8011-88712 Location of Torque Wrench
7
Verigy Restricted Appendix B – Autotransformer Page 7 Autotransformer Wiring Diagram
8
Verigy Restricted Appendix B – Autotransformer Page 8 Autotransformer Power Option Wiring Default configuration from factory is: 480V Do not change Power Output Wiring! Set Power Input Taps to suit local voltage Jumper Wires need to be changed only for 200V
9
Verigy Restricted Appendix B – Autotransformer Page 9 Autotransformer Power Option Setting 1. Torque Wrench Setting: 14Nm 3. Change Input Taps at Control Transformer 2. Change Power Input Taps (Jumper Wires only for 200V)
10
Verigy Restricted Appendix B – Autotransformer Page 10 Autotransformer Breaker Settings Output Breaker ST2 Trip Inrush Trip Inrush Current Multiple Current Multiple STH 440/480V125A x7 90A x6 LTH 200/208V225A x7120A x6 LTH 440/480V 125A x7120A x6 Input Breaker ST1
11
Verigy Restricted Appendix B – Autotransformer Page 11 Autotransformer Replacement Parts Output Breaker ST2 3105-0326 Control Transformer E8001-68503 Fan Power Supply E8001-88501 Cooling Fan E8001-88502 Spare Fuse Set E8011-88712
12
Verigy Restricted Appendix B – Autotransformer Page 12