Download presentation
Presentation is loading. Please wait.
Published byRonald Sutton Modified over 9 years ago
1
1 Interactive Thickness Visualization of Articular Cartilage Author :Matej Mlejnek, Anna Vilanova,Meister Eduard GröllerMatej MlejnekAnna VilanovaMeister Eduard Gröller Source :Proceedings of Visualization 2004, pages 521-527. October 2004 Speaker : Ren-LI Shen Advisor : Ku-Yaw Chang
2
2 Outline Introduction Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
3
3 Introduction Articular cartilage Surfaces of knee joints are covered by tissue Is a curved structure difficult to read the thickness changes
4
4 Introduction Main functions of the cartilage Distribution of weight Frictionless motion Shock absorption
5
5 Introduction Height field Unfolding and depicting Eliminates the complexity of the 3D shape concentrate solely on the inspection Offers several visualization modes Color mapping Scaling Glyphs Iso-lines
6
6 Introduction
7
7 Distortion Minimize the distortion, in a user-defined area Flattening Requires parameterization of the surface
8
8 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
9
9 Pipeline for thickness visualization Consists of the following steps
10
10 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
11
11 Cartilage segmentation Two main classes of segmentation methods Manual segmentation Time-consuming Requires an experienced user Semi-automatic segmentation use thresholding, region growing, snakes, or edge detection filters In this paper they use an active contour model (snake) controlled by internal and external forces
12
12 Cartilage segmentation
13
13 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
14
14 Thickness measurement Several possibilities to calculate Vertical distance Is not appropriate for curved surfaces Proximity method This paper uses Normal distance
15
15 Thickness measurement Euclidean distance Optimizations of distance transforms Chamfer distance transforms propagates the local distance by adding the neighborhood values Vector distance transforms propagates the distance vector to the nearest sample point of the object surface
16
16 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
17
17 Flattening of articular cartilage Flattening cartilage into the corresponding 2D plane should fulfill the following criteria Need a parameterization Minimizes area distortion Local and global intersections have to be prevented Common problem in the area on surface parameterization
18
18 Flattening of articular cartilage Do not allow multiple patches In order to keep spatial relations. Parameterization has to be fast
19
19 Flattening of articular cartilage Efficiently prevent local as well as global intersections Align all points onto a line Reduces the distortion minimization issue
20
20 Flattening of articular cartilage In order to meet all of the constraints Grow a planar patch First, the focal triangle includes the focal point is rigidly transformed into the 2D plane The distance is defined by the height of the focal triangle (height = 2·area / |p2−p1|) Next step, patch is iteratively flattened by adding active points ai to the patch
21
21 Flattening of articular cartilage
22
22 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
23
23 Operations on the height field Slight changes in the thickness on the reconstructed surface may, however, not be noticeable In order to enhance the thickness information Propose a non-uniform scaling only in the height direction
24
24 Operations on the height field
25
25 Operations on the height field
26
26 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
27
27 Thresholded non-linear scaling
28
28 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
29
29 Non-linear scaling on interval Thresholded scaling
30
30 Non-linear scaling on interval
31
31 Non-linear scaling on interval Show the extraction of thickness information enhanced by color coding
32
32 Non-linear scaling on interval By iso-lines
33
33 Non-linear scaling on interval By glyphs
34
34 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
35
35 Scale transfer function Need a tool enables detection of subtle thickness changes on each range of the thickness values Using non-linear scaling approach, interesting features may be occluded by other scaled areas Can be overcome by thresholded non-linear scaling
36
36 Scale transfer function Define a continuous linear scaling transfer function Maps the original thickness values Assigned to each vertex To the scaled values Thickness preservation is performed on intervals, where x = y
37
37 Scale transfer function
38
38 Outline Introduction and medical background Pipeline for thickness visualization Cartilage segmentation Thickness measurement Flattening of articular cartilage Operations on the height field Thresholded non-linear scaling Non-linear scaling on interval Scale transfer function Summary and conclusions
39
39 Summary and conclusions The approach has been illustrated on the visualization of articular cartilage Detection of slight thickness changes is vital for diagnosis Has been shown that unfolding of anatomic organs is promising Future work Continue with a broader clinical study on a variety of datasets
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.